Group: Konica Minolta
Catalog excerpts
WE BRING QUALITY TO LIGHT Standalone XYZ positioners (260 to 560 mm max. travel range) Standalone 2-axis goniometers (up to 70 cm diagonal sample size) Complete turnkey 5-axis positioners with optical table Integrated with SpecWin software for Windows 95/98/NT Luminance and color measurements of graphics and switches Goniometric measurements of lamps and LED modules Display testing in conformance with VESA and ISO standards BRDF reflection measurement of displays INSTRUMENT SYS T E M S OPTISCHE MESSTECHNIK
Open the catalog to page 1Automated display and light measurement Instrument Systems is one of the leading manufacturers of spectrometers for carrying out spectral and light measurements. The motorized positioning systems in the DTS 500 series allow you to create a complete system for automated measurement sequences. Ideal applications include determining the angle-dependent properties of displays and LED lamp modules. The DTS 500 saves you valuable time by eliminating the tedious manual positioning of the device under test. In addition, you obtain measurement results that are more accurate and easier to reproduce....
Open the catalog to page 2Instrument Systems has expanded the SpecWin spectral analysis software to include many new functions for the DTS500 Positioner system. SpecWin also includes an MS Word™ compatible report generator and an MS Excel™ compatible spread- sheet program for fast analy- sis of results during measuring Flat panel displays may be characterized automatically in conformance with VESA or ISO standards by video- generator control (optional). A selection of appropriate test images is available for testing full-screen luminance, contrast ratio and color coordinates. The video generator functions can also...
Open the catalog to page 3XYZ Positioners Benefits at a glance: XYZ positioners from Instrument Systems have been specially designed for use in both the automotive and avionic industry. The software supports user-defined sequences for automated testing of panels and switches. q Robust mechanical setup: the frame design eliminates the need of an optical table in the standalone configuration Using the control pad or keyboard, the user focuses on individual measurement locations on the panel. Each location is then stored in a sequence table such that a complete test series is built up. Alternatively the entire surface...
Open the catalog to page 4The 2-axis goniometers from Instrument Systems allow users to test all angle- 2-Axis Goniometers dependent properties of light sources. As stand-alone units they are idealy suited for measuring illuminance and luminous intensity of luminaires, lamps and LED Benefits at a glance: modules. The software generates iso-contour plots and diagrams of the radiation pattern. Rotation in H and „ (horizontal Automated software trans- formation into different coor- dinate systems (e.g. theta / Quick clamp for rapid fixturing of the test sample Mounting plate for easy mounting of flat panel displays...
Open the catalog to page 5Complete 5-axis positioners Benefits at a glance: q XYZ positioner and 2-axis goniometer on stable optical table q Light-tight hood (optional) eliminates the need for a darkroom q Automatic tracking of the measuring spot when the display rotates q Turnkey solution with system controller The 5-axis systems comprise a 2-axis goniometer and a XYZ positioner. The complete setup is mounted on a robust optical table and positioned under a light-tight hood (optional). A system controller with pre-configured interfaces and settings is included allowing an immediate start of operation. ADDITIONAL...
Open the catalog to page 6COMPLETE 5-AXIS POSITIONERS DTS 500 POSITIONER SYSTEMS Software evaluation The operation of the complete 5-axis system is fully integrated in the SpecWin software. Results are plotted as luminance and contrast distribution in cartesian or spherical coordinates. SpecWin automatically enters iso-contour lines in the diagrams. The data can also be saved as tables in an ExcelTM-compatible ASCII text file. The axes of rotation generally lie outside the plane of measurement during goniometric movements of the display. Furthermore, the measurement locations rarely lie directly on the axis of...
Open the catalog to page 7ORDERING INFORMATION XYZ POSITIONER (other travel ranges available on request) DTS500-101 260 x 180 x 260 mm travel range in XYZ DTS500-103 360 x 280 x 360 mm travel range in XYZ DTS500-105 560 x 480 x 460 mm travel range in XYZ 2-axis goniometer DTS500-111 290 x 200 mm max. display Size (W x H); sample weight on request DTS500-113 350 x 280 mm max. display Size (W x H); sample weight max. 10 kg DTS500-115 550 x 440 mm max. display Size (W x H); sample weight max. 25 kg Complete 5-axis positioner DTS500-213 Complete system incl. on-site installation, comprising: q DTS500-103 XYZ Positioner...
Open the catalog to page 8All Konica Minolta Sensing Americas catalogs and technical brochures
-
LumiTop Series
16 Pages
-
LumiSuite
8 Pages
-
CAS140D_IR
2 Pages
-
CAS140CT_IR
8 Pages
-
CAS125
4 Pages
-
LumiCam 4000B_2400B_V2
12 Pages
-
ISP Series
16 Pages
-
DTS 140D NVIS
5 Pages
-
ACS & ACU Series
12 Pages
-
Spectrophotometer CM-36dG
8 Pages
-
LGS 650
8 Pages
-
LumiCam Series
16 Pages
-
CAS 120
8 Pages
-
CAS 140D
16 Pages
-
New GM series gloss
4 Pages
-
Spectrophotometer CM-5
3 Pages
-
SPECTROPHOTOMETER CM-3700A
3 Pages
-
CRI Illuminance Meter CL-70F
2 Pages
-
Chroma Meter CS-150
3 Pages
-
CHROMA METER CS-200
6 Pages
-
Chroma Meter CL-200A
4 Pages
-
2D Color Analyzer CA-2500
8 Pages
-
Skin Analysis Software CM-SA
4 Pages
-
GTI GLE-M
2 Pages
-
GTI MiniMatcher Series
2 Pages
-
Rhopoint TAMS™
6 Pages
-
Rhopoint IQ FLEX 20
2 Pages
-
Uni Gloss 60A/S/CT
4 Pages
-
BC-10 Plus
4 Pages
-
CR-410PB
4 Pages
-
CR-400/410
5 Pages
-
CM-3700A
3 Pages
-
CM-700d/600d
3 Pages
-
cm-25cg
2 Pages
-
cm-m6
2 Pages
-
DTS140 NVIS
6 Pages
-
Rhopoint IQ-S
4 Pages
-
RHOPTOINT instruments
6 Pages
-
LumiCam 2400
4 Pages
-
Medidor de Brillo 268A
4 Pages
-
CM-25cG
4 Pages
-
FD-9
6 Pages
-
RHOPOINT Flex 60 / Flex 20
2 Pages
-
CR-20
2 Pages
-
CR-10 Plus
2 Pages
-
ISP Series Integrating Spheres
17 Pages
-
LCS IV
1 Pages
-
ISP40
4 Pages
-
LGS 1000
4 Pages
-
LGS 350
8 Pages
-
ISP 500
4 Pages
-
ISP 2000
2 Pages
-
ISP 150L
2 Pages
-
ISP 1000
4 Pages
-
LEDGON LED GONIOPHOTOMETER
4 Pages
-
LED-81X/-850
4 Pages
-
ACS-530
4 Pages
-
LED 25
4 Pages
-
LSM 350
4 Pages
-
THE DTS 400 SYSTEM
2 Pages
-
LUMICAM 1300
8 Pages
-
CAS 140CTS
4 Pages
-
MAS 40
8 Pages
-
SPECTRO 320
12 Pages
-
MM-4E CONTROLLED LIGHTING
2 Pages
-
CM-600D SPECTROPHOTOMETER
3 Pages
-
CR-410C Coffee
2 Pages
-
Chlorophyll Meter SPAD-502
2 Pages
-
MULTI GLOSS 268PLUS
2 Pages
-
CM-SA SKIN ANALYSIS SOFTWARE
4 Pages
-
CM-5 SPECTROPHOTOMETER
3 Pages