Group: Konica Minolta
Catalog excerpts
CAS 140CT IR Series Array spectrometer for high accuracy infrared light measurement We bring quality to light. Instrument Systems } CAS 140CT IR Series
Open the catalog to page 1Key features at a glance y Two model variants to cover wavelength from 780 nm – 2150 nm y igh-performance InGaAs linear image sensor H with wide dynamic range y Spectrograph design optimized for NIR/SWIR wavelength applications and high-sensitivity performance y Thermoelectric cooling down to -20 °C for low dark current and enhanced stability y Extensive range of accessories for different measurement challenges 01 \\ AS 140CT IR series – C Benchmark for accuracy The CAS 140CT IR series of spectroradiometers from Instrument Systems are high-performance array spectrometers that have been...
Open the catalog to page 202 \\ Extended wavelength range Special applications require that a wide wavelength range from UV to infrared can be covered within a single measurement. With the two CAS 140CT IR-models a spectral range of 780 – 1650 nm (IR1) or 1500 – 2150 nm (IR2) can be analyzed. Using the CAS 140D a spectral range from 200 nm to 1100 nm can be covered. A parallel measurement can be performed with instruments of the CAS 140D series in order to simultaneously record the UV and VIS range. MultiCAS add-on The MultiCAS add-on for the software application SpecWin Pro permits the combination of CAS 140D and...
Open the catalog to page 3Software development kit with DLL and LabVIEW driver A software development kit (SDK) is available for custom programming or integration into production sequences. In addition to a DLL library, the SDK incorporates valuable sample programs and programming aids. The DLL already contains all colorimetric calculations, for easy integration in customized measurement systems and evaluation of readings. In addition, a driver for programming measurement processes in LabVIEW is available for laboratory use of the CAS 140CT. To store a sequence of very fast measurements in burst mode as described...
Open the catalog to page 4Transmission and reflection measurements Due to high stability and stray light suppression, the CAS 140CT IR is also optimally suited to transmission and reflection measurements. Combined with the appropriate measurement adapter, the CAS 140CT IR is the ideal measurement system for the respective application. In addition to measurement tasks in the range of directional transmission, such as the examination of optical filters and lenses, it permits the examination of the diffuse transmission and reflection of scattering samples and solar cells. Calibration equipment Instrument Systems offers...
Open the catalog to page 506 \\ Service and support We at Instrument Systems are setting a benchmark not only with our products. Our services secure the long-term value of your investment and guarantee optimum productivity over the entire period of use. Our service offerings include the following: y ngineering services E y Technical advice, also post-sales y Re-calibration with certificate y Instrument repair and hardware upgrade y Software updates 07 \\ Technical specifications Model Spectral range Pixel number Integration time Dynamic range Spectral resolution Data point interval Wavelength accuracy Non-linearity...
Open the catalog to page 6Power supply Power consumption Ambient temperature 15 – 35 °C; relative humidity 0 – 70 %, non-condensing Applicable standards In conformity with EN 60721-4-7 Class 7M2, EN 60721-4-7 Class 2M2, EN 61326:2004-05 and EN 61010-2002-08 Measurement uncertainty Accuracy Radiant Flux Instrument precision Approximate values for 100 µm (IR1) and 250 µm (IR2) standard slit. For IR1 High-Gain, only valid for the spectral range 780 nm – 1650 nm. For a single acquisition with 10ms integration time. Measured with long pass filter FELH1100 at 900nm, relative to peak intensity of unweighted spectral data....
Open the catalog to page 7We bring quality to light. Instrument Systems } CAS 140CT IR Series
Open the catalog to page 8All Konica Minolta Sensing Americas catalogs and technical brochures
-
LumiTop Series
16 Pages
-
LumiSuite
8 Pages
-
CAS140D_IR
2 Pages
-
CAS125
4 Pages
-
LumiCam 4000B_2400B_V2
12 Pages
-
ISP Series
16 Pages
-
DTS 140D NVIS
5 Pages
-
ACS & ACU Series
12 Pages
-
Spectrophotometer CM-36dG
8 Pages
-
LGS 650
8 Pages
-
LumiCam Series
16 Pages
-
CAS 120
8 Pages
-
CAS 140D
16 Pages
-
New GM series gloss
4 Pages
-
Spectrophotometer CM-5
3 Pages
-
SPECTROPHOTOMETER CM-3700A
3 Pages
-
CRI Illuminance Meter CL-70F
2 Pages
-
Chroma Meter CS-150
3 Pages
-
CHROMA METER CS-200
6 Pages
-
Chroma Meter CL-200A
4 Pages
-
2D Color Analyzer CA-2500
8 Pages
-
Skin Analysis Software CM-SA
4 Pages
-
GTI GLE-M
2 Pages
-
GTI MiniMatcher Series
2 Pages
-
Rhopoint TAMS™
6 Pages
-
Rhopoint IQ FLEX 20
2 Pages
-
Uni Gloss 60A/S/CT
4 Pages
-
BC-10 Plus
4 Pages
-
CR-410PB
4 Pages
-
CR-400/410
5 Pages
-
CM-3700A
3 Pages
-
CM-700d/600d
3 Pages
-
cm-25cg
2 Pages
-
cm-m6
2 Pages
-
DTS140 NVIS
6 Pages
-
Rhopoint IQ-S
4 Pages
-
RHOPTOINT instruments
6 Pages
-
LumiCam 2400
4 Pages
-
Medidor de Brillo 268A
4 Pages
-
CM-25cG
4 Pages
-
FD-9
6 Pages
-
RHOPOINT Flex 60 / Flex 20
2 Pages
-
CR-20
2 Pages
-
CR-10 Plus
2 Pages
-
ISP Series Integrating Spheres
17 Pages
-
LCS IV
1 Pages
-
ISP40
4 Pages
-
LGS 1000
4 Pages
-
LGS 350
8 Pages
-
ISP 500
4 Pages
-
ISP 2000
2 Pages
-
ISP 150L
2 Pages
-
ISP 1000
4 Pages
-
LEDGON LED GONIOPHOTOMETER
4 Pages
-
LED-81X/-850
4 Pages
-
ACS-530
4 Pages
-
LED 25
4 Pages
-
LSM 350
4 Pages
-
DTS 500 SPECTRORADIOMETER
8 Pages
-
THE DTS 400 SYSTEM
2 Pages
-
LUMICAM 1300
8 Pages
-
CAS 140CTS
4 Pages
-
MAS 40
8 Pages
-
SPECTRO 320
12 Pages
-
MM-4E CONTROLLED LIGHTING
2 Pages
-
CM-600D SPECTROPHOTOMETER
3 Pages
-
CR-410C Coffee
2 Pages
-
Chlorophyll Meter SPAD-502
2 Pages
-
MULTI GLOSS 268PLUS
2 Pages
-
CM-SA SKIN ANALYSIS SOFTWARE
4 Pages
-
CM-5 SPECTROPHOTOMETER
3 Pages