CAS125
4Pages

{{requestButtons}}

Catalog excerpts

CAS125 - 1

CAS 125 Array Spectrometer Productivity and Reliability Key features at a glance y y y y y Very short integration times down to 10 µs 2 048 pixels CMOS sensor with thermal stabilization Recipe Mode for ultrafast measurement sequences M ax. scan rate of 3700 scans/s Robust housing with smaller footprint The new CAS 125 extends the series of well-established high-performance spectroradiometers from Instrument Systems into the field of price-sensitive applications such as LED production testing and quality assurance. The “plug & play” function allows a high degree of process reliability. The system automatically recognizes the connected accessories and ensures that only current and valid calibrations are used. The novel recipe mode significantly increases productivity in timecritical high-throughput applications. \\ PROVEN OPTICAL SETUP A crossed Czerny-Turner spectrograph forms the core of the CAS 125. The optical setup is adopted from the proven CAS 140D which is the undisputed industry standard for laboratory applications. This design guarantees maximum optical precision with exceptionally good stray light rejection. Unique technical innovations integrated in the CAS 125 result in a high level of reliability and speed. A thermal stabilization of the sensor ensures operation independent from changing environmental conditions. Model variants ranging from 200  nm up to 1100  nm and the highquality optical setup guarantee precise results for diverse measurement tasks. The economic design with a robust housing and smaller footprint is specially designed for the demanding conditions experienced in 24/7 operation. The new CAS 125 satisfies the high requirements on accuracy and versatility from high-volume production applications to diverse laboratory tasks. Model Information Model ~ Optical setup of the CAS 125 with optimized crossed CzernyTurner Spectrograph. Filter wheel Various filter-wheel combinations are available (OD 0.5 to OD

Open the catalog to page 1
CAS125 - 2

\\ EXTENSIVE SOFT- & HARDWARE PACKAGE \\ “RECIPE MODE” FOR ULTRAFAST MEASUREMENT SEQUENCES The CAS 125 is equipped with Ethernet interface and hardware trigger. The integrated density filter wheel and the dark-current shutter additionally facilitate fully automated measurements over an extremely broad signal range. A software development kit (SDK) with DLL driver allows fast and easy integration of the CAS 125 into production environment. In addition, SpecWin Pro and SpecWin Light provide an extensive range of spectral analysis tools and hardware interfaces for diverse laboratory tasks. The...

Open the catalog to page 2
CAS125 - 3

\\ TECHNICAL SPECIFICATIONS CAS 125 Array Spectrometer Model Spectrophotometry Baseline noise Transmission measuring accuracy Baseline drift Spectrograph Focal length, f number, grating Approx. 120 mm, f/3.5, plane reflection grating Filter wheel / shutter Max. 7 slots for density filters OD 0.5 to OD 4; UV/VIS and UV/VIS/NIR with UV density filters; position monitoring with encoder Electrical data AD converter Input: 5V TTL ascending slope; output: 2 TTL outputs External Power supply Wide-range input (external) 100 VAC to 240 VAC 50/60 Hz Device Power supply Power consumption Ambient...

Open the catalog to page 3
CAS125 - 4

Sensor with thermal stabilization. Binned to 1024 data points. 3) Depends on integration time, device settings and performance of operating computer / system. 4) Single acquisition with 1 ms integration time. 5) Measured with edge filter OG455 at 400 nm, relative to peak intensity of unweighted spectral data. 6) Measured 150 nm to left of the peak wavelength, relative to peak intensity of unweighted spectral data. 7) Measured with optical probe EOP-120 and OFG-414 fiber bundle at 600 nm and signal/noise ratio of 10:1, without averaging. 8) Applies to a signal-to-noise ratio of 10:1....

Open the catalog to page 4

All Konica Minolta Sensing Americas catalogs and technical brochures

  1. LumiTop Series

    16 Pages

  2. LumiSuite

    8 Pages

  3. CAS140D_IR

    2 Pages

  4. CAS140CT_IR

    8 Pages

  5. ISP Series

    16 Pages

  6. LGS 650

    8 Pages

  7. LumiCam Series

    16 Pages

  8. CAS 120

    8 Pages

  9. CAS 140D

    16 Pages

  10. GTI GLE-M

    2 Pages

  11. BC-10 Plus

    4 Pages

  12. CR-410PB

    4 Pages

  13. CR-400/410

    5 Pages

  14. CM-3700A

    3 Pages

  15. CM-700d/600d

    3 Pages

  16. cm-25cg

    2 Pages

  17. cm-m6

    2 Pages

  18. DTS140 NVIS

    6 Pages

  19. LumiCam 2400

    4 Pages

  20. CM-25cG

    4 Pages

  21. FD-9

    6 Pages

  22. Colibri®

    6 Pages

  23. CR-20

    2 Pages

  24. CR-10 Plus

    2 Pages

  25. LCS IV

    1 Pages

  26. ISP40

    4 Pages

  27. LGS 1000

    4 Pages

  28. LGS 350

    8 Pages

  29. ISP 500

    4 Pages

  30. ISP 2000

    2 Pages

  31. ISP 150L

    2 Pages

  32. ISP 1000

    4 Pages

  33. LED-81X/-850

    4 Pages

  34. ACS-530

    4 Pages

  35. LED 25

    4 Pages

  36. LSM 350

    4 Pages

  37. LUMICAM 1300

    8 Pages

  38. CAS 140CTS

    4 Pages

  39. MAS 40

    8 Pages

  40. SPECTRO 320

    12 Pages

  41. COLIBRI

    6 Pages