ACS & ACU Series
12Pages

{{requestButtons}}

Catalog excerpts

ACS & ACU Series - 1

ACS & ACU Series Advanced Calibration Standards White, RGB, UV and IR We bring quality to light.

Open the catalog to page 1
ACS & ACU Series - 2

Key features at a glance y Advanced Calibration Standards on LED basis available in white, RGB, UV and IR y Reference values for radiant or luminous flux, averaged LED intensity and luminance traceable to PTB standards (in conformity with DIN ISO 17025) y Specification of color coordinates and dominant wavelength or color temperature if applicable y 0.2 % photometric stability over min. 100 operating hours for ACS standards with white LED y Maximum operational reliability by use with an ACU control unit 01 \\ dvanced Calibration Standards – A from UVC to IR The LED calibration standards of...

Open the catalog to page 2
ACS & ACU Series - 3

ACS-570-x – LED calibration standards for luminous flux and luminous intensity 100 Red LED Spectral radiant power / /% Spectral radiant power % The ACS 570 LED calibration standards for luminous flux and averaged LED intensity ILED-B are available in cool white (ACS-570-1) and the three basic colors blue (-3), green (-5) and red (-7). This covers the entire visible spectral range. Normally, the white ACS-570-1 is used for the calibration of all larger integrating spheres ISP and luminous intensity adapters LED-4xx from Instrument systems. Typical luminous flux values are 20 - 30 lm and the...

Open the catalog to page 3
ACS & ACU Series - 4

ACS-570-2x – UV LED calibration standards for radiant flux The ACS 570 UV LED calibration standards from Instrument Systems are available in three versions with typical peak wavelengths for UVC (on request), 305 nm for UVB (ACS-570-26), and 365 nm for UVA (ACS-570-28). The extremely low measurement uncertainties (k = 2) of only 3.5% in UVB and 2% in UVA are comparatively low as in the visible range, which is metrologically less challenging. UV-LED calibration standards can be used for monitoring and for the absolute calibration of special UV measurement equipment such as integrating spheres...

Open the catalog to page 4
ACS & ACU Series - 5

ACS 586/587 – LED luminance standards The ACS 586/587 are new, highly stable LED luminance standards. They support testing of all luminance meters on both filter and spectroradiometric basis. The radiation of the high-power LED is emitted into an integrating sphere with an inner diameter of 100 mm through a diffuser. The inner layer of the integrating sphere homogenizes further the radiation and emits homogeneous luminance through an opening of 25 mm in diameter. This structure ensures that the LED luminance standard has Lambertian radiation characteristics. The reference values, the...

Open the catalog to page 5
ACS & ACU Series - 6

02 \\ dvanced Technology behind A Advanced Standards ACU The ACU is a new compact control unit for ACS calibration standards from Instrument Systems. It contains a high-precision constant current source in a compact desktop housing in addition to a TEC controller for accurate temperature stabilization. The ACU has been developed for both laboratory and production use. The ACU is controlled by means of a computer via USB using the ACSControl software. Both, Windows 10 and OS X operating systems are supported. Moreover, the relevant program libraries (.dll and .dylib) are available for direct...

Open the catalog to page 6
ACS & ACU Series - 7

After completion of the short stabilization phase, the forward voltage and the temperature remain constant. The radiant power of the LED therefore remains constant over a long service life and the fast operational readiness saves valuable time. ACS 570 in application ACS 570 can be applied to monitor various systems. For luminous flux measurements with ACS 570 there are adapters available for all spheres manufactured by Instrument Systems. The adapters are universally applicable with all our LED test sockets. For averaged LED intensity measurements, the ACS 570 can be connected directly to...

Open the catalog to page 7
ACS & ACU Series - 8

04 \\ echnical Specifications T VIS LED calibration standards cool white Typical luminous flux [lm] Typical averaged LED intensity I-LED-B [cd] Typical dominant wavelength / Correlated color temp. CCT Operating current and accuracy Operating temperature at the control point and accuracy Ambient conditions Temporal stability of the luminous flux and luminous intensity Temporal stability of the color coordinates x and y Time to operational readiness Recommended recalibration interval After 300 operating hours or one year Temperature dependence of the luminous flux / intensity Temperature...

Open the catalog to page 8
ACS & ACU Series - 9

Typical irradiance @ 300 mm distance [mW/m²] Typical radiant flux [mW] Expanded measurement uncertainty (k=2) Typical peak wavelength Typical centroid wavelength Operating current and accuracy Operating temperature at control point and accuracy Maximum relative change over the ON time Temperature dependency of the calibration value Turn-on stabilization time Recommended recalibration interval One year after last calibration Sub-D, 25-pole (ACS to control unit); USB (control unit to PC) Alternative with ACS-570-9 to the combination Keithley / Arroyo LED luminance standard ACS-586-1 Diameter...

Open the catalog to page 9
ACS & ACU Series - 10

ACS 150X LED light source for 2D/CAS audit Diameter of the light-emitting aperture Long-term stability of spatial non-uniformity in Lv Long-term stability of spatial non-uniformity in x, y Turn-on stabilization time Mechanical Data Photometric / Colorimetric Data Luminance Correlated color temperature (CCT) Spatial non-uniformity (RNU) in luminance 3) Spatial non-uniformity (RNU) in chromaticity coordinates Recommended recalibration interval Long-term stability Long-term stability of luminance 1) Long-term stability of chromaticity coordinates Sensitivity to ambient conditions (variation of...

Open the catalog to page 10
ACS & ACU Series - 11

05 \\ rdering Information O Order number White high-power LED calibration standard in socket with 25 mm Ø Blue high-power LED calibration standard in socket with 25 mm Ø Green high-power LED calibration standard in socket with 25 mm Ø Red high-power LED calibration standard in socket with 25 mm Ø IR-LED calibration standard for radiant flux (860 nm) in socket with 25 mm Ø IR-LED calibration standard for radiant flux (950 nm) in socket with 25 mm Ø IR-LED calibration standard (~1200 nm) in socket with 25 mm Ø IR-LED calibration standard (~1300 nm) in socket with 25 mm Ø IR-LED calibration...

Open the catalog to page 11

All Konica Minolta Sensing Americas catalogs and technical brochures

  1. LumiTop Series

    16 Pages

  2. LumiSuite

    8 Pages

  3. CAS140D_IR

    2 Pages

  4. CAS140CT_IR

    8 Pages

  5. CAS125

    4 Pages

  6. ISP Series

    16 Pages

  7. LGS 650

    8 Pages

  8. LumiCam Series

    16 Pages

  9. CAS 120

    8 Pages

  10. CAS 140D

    16 Pages

  11. GTI GLE-M

    2 Pages

  12. BC-10 Plus

    4 Pages

  13. CR-410PB

    4 Pages

  14. CR-400/410

    5 Pages

  15. CM-3700A

    3 Pages

  16. CM-700d/600d

    3 Pages

  17. cm-25cg

    2 Pages

  18. cm-m6

    2 Pages

  19. DTS140 NVIS

    6 Pages

  20. LumiCam 2400

    4 Pages

  21. CM-25cG

    4 Pages

  22. FD-9

    6 Pages

  23. Colibri®

    6 Pages

  24. CR-20

    2 Pages

  25. CR-10 Plus

    2 Pages

  26. LCS IV

    1 Pages

  27. ISP40

    4 Pages

  28. LGS 1000

    4 Pages

  29. LGS 350

    8 Pages

  30. ISP 500

    4 Pages

  31. ISP 2000

    2 Pages

  32. ISP 150L

    2 Pages

  33. ISP 1000

    4 Pages

  34. LED-81X/-850

    4 Pages

  35. ACS-530

    4 Pages

  36. LED 25

    4 Pages

  37. LSM 350

    4 Pages

  38. LUMICAM 1300

    8 Pages

  39. CAS 140CTS

    4 Pages

  40. MAS 40

    8 Pages

  41. SPECTRO 320

    12 Pages

  42. COLIBRI

    6 Pages