KONCAR-Institute-Slow Roll Runout Instrument
3Pages

{{requestButtons}}

Catalog excerpts

KONCAR-Institute-Slow Roll Runout Instrument - 1

SRI specification Architecture: • Data acquisition unit with the real time controller and 6,7” touch display Inputs: • Eight voltage input for relative displacement measurement (0-10 V) (more inputs on request) • One voltage input for key phasor measurement (0-24 V) Communication: • Ethernet 10/100 Power supply: • DC: 80 V to 370 V • AC: 85 to 264 V , frequency 47 to 63 Hz • Maximum allowed power supply interruption: 100 ms for 230 VAC/ 20 ms for 115 VAC • Test voltage: 3 kV (2 kV against ground) Temperature range: • Operational temperature range: -20°C to +70°C (storage temperature: -40° to +85°C) Dimensions: • Suitcase – typical dimensions WHD: 430x320x180 • Cabinet – Typical dimensions WHD: 400x400x300 Data visualization: • 6,7 ” touch display for local HMI • Web browser for local and remote access Data logging: • Database for long-term data archival Standards compliance: • EMC immunity/emission : EN 61326-1 (IEC 61326-1:2005), EN 61000-3-2+A1+A2 (IEC 61000-3-2+A1+A2), EN 61000-3-3 (IEC 61000-3-3), EN 61000-4-10+A1 (IEC 61000-4-10+A1), EN 61000-4-12 (IEC 61000-4-12), EN 61000-4-18+A1 (IEC 61000-4-18+A1) • Vibration/shock resistance (EN 60068-2-6/EN 60068-2-27/29) KONČAR – Electrical Engineering Institute Inc. Department for rotating machines Fallerovo šetalište 22, 10 000 Zagreb, Croatia Phone: + 385 1 3656 291 Fax: +385 1 3666 377 Web: www.kon

Open the catalog to page 1
KONCAR-Institute-Slow Roll Runout Instrument - 2

SLOW-ROLL RUNOUT INSTRUMENT SRI instrument measures mechanical imperfections such as out-of-roundness and non-concentricity with respect to the bearing surface, with relative displacement probes positioned over track area that is adjacent to each bearing. The reading which results from these imperfections, usually known as runout, must be reduced if it exceeds the recommended value. AGAP Features • On-line analysis • Automatic report generation • Data export to other systems • Database for long-term data archival • Detailed of-line measurement data analysis • Comparisons to earlier recorded...

Open the catalog to page 2
KONCAR-Institute-Slow Roll Runout Instrument - 3

SRI specification Architecture: • Data acquisition unit with the real time controller and 6,7" touch display Inputs: • Eight voltage input for relative displacement measurement (0-10 V) (more inputs on request) • One voltage input for key phasor measurement (0-24 V) Communication: • Ethernet 10/100 Power supply: • DC: 80 V to 370 V • AC: 85 to 264 V, frequency 47 to 63 Hz • Maximum allowed power supply interruption: 100 ms for 230 VAC/ 20 ms for 115 VAC • Test voltage: 3 kV (2 kV against ground) Temperature range: • Operational temperature range: -20°C to +70°C (storage temperature: -40° to...

Open the catalog to page 3