KONCAR-Institute-Slow Roll Runout Instrument

KONCAR-Institute-Slow Roll Runout Instrument

KONCAR-Institute-Slow Roll Runout Instrument

Product catalog summary
Architecture:
The system includes a data acquisition unit with a real-time controller and a 6.7-inch touch display.
Inputs:
It supports eight voltage inputs for relative displacement measurement (0-10 V) and one voltage input for key phasor measurement (0-24 V). Additional inputs can be requested.
Communication:
Ethernet 10/100 is used for communication.
Power Supply:
The device operates on DC (80 V to 370 V) and AC (85 to 264 V, 47 to 63 Hz). It can withstand power supply interruptions of up to 100 ms for 230 VAC and 20 ms for 115 VAC. The test voltage is 3 kV (2 kV against ground).
Temperature Range:
Operational temperature ranges from -20°C to +70°C, with storage temperatures from -40°C to +85°C.
Dimensions:
The suitcase version measures 430x320x180 mm, while the cabinet version measures 400x400x300 mm.
Data Visualization:
Features a 6.7-inch touch display for local HMI and web browser access for local and remote data visualization.
Data Logging:
Includes a database for long-term data archival.
Standards Compliance:
Complies with EMC immunity/emission standards (EN 61326-1, EN 61000 series) and vibration/shock resistance standards (EN 60068 series).
SRI Specification:
The SRI instrument measures mechanical imperfections such as out-of-roundness and non-concentricity using relative displacement probes. It helps reduce runout if it exceeds recommended values.
AGAP Features:
Offers online analysis, automatic report generation, data export, long-term data archival, detailed offline data analysis, and comparisons to earlier data. It aids in reducing potential damage costs and improving asset management.
See more

Catalog excerpts

KONCAR-Institute-Slow Roll Runout Instrument-1

SRI specification Architecture: • Data acquisition unit with the real time controller and 6,7” touch display Inputs: • Eight voltage input for relative displacement measurement (0-10 V) (more inputs on request) • One voltage input for key phasor measurement (0-24 V) Communication: • Ethernet 10/100 Power supply: • DC: 80 V to 370 V • AC: 85 to 264 V , frequency 47 to 63 Hz • Maximum allowed power supply interruption: 100 ms for 230 VAC/ 20 ms for 115 VAC • Test voltage: 3 kV (2 kV against ground) Temperature range: • Operational temperature range: -20°C to +70°C (storage temperature: -40° to +85°C) Dimensions: • Suitcase – typical dimensions WHD: 430x320x180 • Cabinet – Typical dimensions WHD: 400x400x300 Data visualization: • 6,7 ” touch display for local HMI • Web browser for local and remote access Data logging: • Database for long-term data archival Standards compliance: • EMC immunity/emission : EN 61326-1 (IEC 61326-1:2005), EN 61000-3-2+A1+A2 (IEC 61000-3-2+A1+A2), EN 61000-3-3 (IEC 61000-3-3), EN 61000-4-10+A1 (IEC 61000-4-10+A1), EN 61000-4-12 (IEC 61000-4-12), EN 61000-4-18+A1 (IEC 61000-4-18+A1) • Vibration/shock resistance (EN 60068-2-6/EN 60068-2-27/29) KONČAR – Electrical Engineering Institute Inc. Department for rotating machines Fallerovo šetalište 22, 10 000 Zagreb, Croatia Phone: + 385 1 3656 291 Fax: +385 1 3666 377 Web: www.kon

 Open the catalog to page 1
KONCAR-Institute-Slow Roll Runout Instrument-2

SLOW-ROLL RUNOUT INSTRUMENT SRI instrument measures mechanical imperfections such as out-of-roundness and non-concentricity with respect to the bearing surface, with relative displacement probes positioned over track area that is adjacent to each bearing. The reading which results from these imperfections, usually known as runout, must be reduced if it exceeds the recommended value. AGAP Features • On-line analysis • Automatic report generation • Data export to other systems • Database for long-term data archival • Detailed of-line measurement data analysis • Comparisons to earlier recorded data...

 Open the catalog to page 2
KONCAR-Institute-Slow Roll Runout Instrument-3

SRI specification Architecture: • Data acquisition unit with the real time controller and 6,7" touch display Inputs: • Eight voltage input for relative displacement measurement (0-10 V) (more inputs on request) • One voltage input for key phasor measurement (0-24 V) Communication: • Ethernet 10/100 Power supply: • DC: 80 V to 370 V • AC: 85 to 264 V, frequency 47 to 63 Hz • Maximum allowed power supply interruption: 100 ms for 230 VAC/ 20 ms for 115 VAC • Test voltage: 3 kV (2 kV against ground) Temperature range: • Operational temperature range: -20°C to +70°C (storage temperature: -40° to +85°C) Dimensions: •...

 Open the catalog to page 3

All KONCAR - Electrical Engineering Institute Inc. catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.