LA&P specification Kay phasor: • Type: high sensitive infrared fork optical sensor • Switching frequency: up to 500 kHz • Load angle measurement accuracy: < 0,5 % • Switching state indicator: yellow/green led • Operating temperature range: -20°C to +70°C • Size: 80x50x10, Aluminum housing IP67 (integrated electronics) • Digital output: NPN/PNP Digital/relay outputs: • Number of outputs: 2 to 8 • Continuous current: 6 A • Maximum switching power: 1500 VA • Maximum switching voltage: 250 VAC/DC • Maximum switching frequency: 0,1 Hz • Rated isolation voltage: 300 V overload (category III) by EN 50178 • Surge withstand: 4 kV (1,25/50 µs), by IEC 5017 Analog outputs (number of outputs and configuration on request) • Current outputs 0/4 - 20 mA, voltage outputs 0 - 10 V • Number of outputs : 2 to 8 Communication: • Ethernet 10/100 • Supported protocols: Modbus TCP slave, FTP server, IEC 60870-104, HTTP server (other on request) Power supply: • AC: 85 to 264 V , frequency 47 to 63 Hz, DC: 80 V to 370 V • Maximum allowed power supply interruption: 100 ms for 230 VAC/ 20 ms for 115 VAC • Test voltage: 3 kV (2 kV against ground) Temperature range: • Operational temperature range: -20°C to +70°C (-0°C to +55°C for touch screen version) • Storage temperature range: -40° to +85°C Dimensions: • 19” installation – WHD: 482,5x177,5x250 • Cabinet IP 54 (IP 66 on request) – WHD: 300x300x200 Standards compliance: • EMC immunity/emission : EN 61326-1 (IEC 61326-1:2005), EN 61000-3-2+A1+A2 (IEC 61000-3-2+A1+A2), EN 61000-3-3 (IEC 61000-3-3), EN 61000-4-10+A1 (IEC 61000-4-10+A1), EN 61000-4-12 (IEC 61000-4-12), EN 61000-4-18+A1 (IEC 61000-4-18+A1) • Vibration/shock resistance (EN 60068-2-6/EN 60068-2-27/29) KONČAR – Electrical Engineering Institute Inc. Department for rotating machines Fallerovo šetalište 22, 10 000 Zagreb, Croatia Phone: + 385 1 3656 291 Fax: +385
Open the catalog to page 1LOAD ANGLE & POWER MEASURMENT SYSTEM Web HMI (real time data, trends, spectrum, alarms ) One of the key parameters of the generator, in sense of control and stability protection, is the angle of the induced voltage internal to the generator (load angle). Current practice is to estimate this value using measurements from the terminals of the generator and mathematical models. Load Angle & Power System (LA&P) enables direct measurement of the generator load angle based on key phasor and electrical values measurement of the generator. Besides load angle measurement, LA&P system enables...
Open the catalog to page 2LA&P specification Kay phasor: • Type: high sensitive infrared fork optical sensor • Switching frequency: up to 500 kHz • Load angle measurement accuracy: <0,5% • Switching state indicator: yellow/green led • Operating temperature range: -20°C to +70°C • Size: 80x50x10, Aluminum housing IP67 (integrated electronics) • Digital output: NPN/PNP Digital/relay outputs: • Number of outputs: 2 to 8 • Continuous current: 6 A • Maximum switching power: 1500 VA • Maximum switching voltage: 250 VAC/DC • Maximum switching frequency: 0,1 Hz • Rated isolation voltage: 300 V overload (category III) by EN...
Open the catalog to page 3All KONCAR - Electrical Engineering Institute Inc. catalogs and technical brochures
-
HIGH VOLTAGE LABORATORY
6 Pages
-
Thermo Power Plant Plomin 2
20 Pages
-
Wind turbine KO - VA 57 / 1
2 Pages
-
Wind turbine K80
2 Pages
-
KONCAR-Institute-PECS GUIDE
6 Pages
-
KONCAR-Institute-GRAP IDE
2 Pages