High Voltage Switchgear Bay Monitoring System - koncar bms Monitoring of high-voltage switchgear provides: • insight into real-time HV switchgear condition • condition based maintenance • incipient fault detection • prevention and reduction of fault consequences (cost reductions) • continuous information on switchgear condition • information about HV switchgear operating conditions (loads at switching operations, assessment of the residual life) • increased availability • fault cause analysis Tools • alarms ■ trend monitoring ■ real-time information • survey of recorded wave shapes and measuring values ■ recommendations for maintenance of the equipment Monitored quantities: Circuit breaker - phase voltage - main circuit current - close coil current - trip coil current - contact travel - hydraulic pressure - SF6 temperature - SF6 dew point - SFe density - close trigger - open trigger - motor trigger - circuit breaker open/closed - gas pressure at 20°C - arc integral - switching times (make, closing, close-open) - contact velocity - variations of gas pressure at various operations - coil current fingerprint comparison / grey zone checking Disconnector - contact travel - motor current - open trigger - close trigger - disconnector open/closed - switching times (make, closing, close-open) - contact velocity Instrument transformer - hydrostatic pressure KONCAR Electrical Engineering INSTITUTE

 Open the catalog to page 1
KONCAR-Institute-High Voltage Switchgear Bay Monitoring System - BMS-2

(prikupljanje signala) 0 RT (real time o brad a podataka, priprema za slanje, sinkronizacija vremena sa serverom) Q. o DB manager (serverska aplikacija, SQL fitanje baze )_! Signal procesing (serverska aplikacija, obrada rezultata, priprema za bazu) Control Unit Features and benefits of KONCAR BMS (Bay Monitoring System) Simple Ethernet 10/100 connectivity Ethernet-based BMS communication enables simple LAN connectivity with other systems in a switchgear. IEC 61850 Monitoring system's communication protocol satisfies the request of IEC 61850 8-1 standard for the design of electrical substation...

 Open the catalog to page 2

All KONCAR - Electrical Engineering Institute Inc. catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.