Catalog excerpts
AGAP specification Architecture: • Data acquisition unit with the real time controller and 5,7” touch display Inputs: • One voltage input for stator voltage measurement (0-10 V) (more inputs on request) • One voltage input for key phasor measurement (0-10 V) Communication: • Ethernet 10/100 Power supply: • DC: 80 V to 370 V • AC: 85 to 264 V , frequency 47 to 63 Hz • Maximum allowed power supply interruption: 100 ms for 230 VAC/ 20 ms for 115 VAC • Test voltage: 3 kV (2 kV against ground) Temperature range: • Operational temperature range: -20°C to +70°C (storage temperature: -40° to +85°C) Dimensions: • Suitcase – typical dimensions WHD: 430x320x180 • Cabinet – Typical dimensions WHD: 400x400x300 Data visualization: • 5,7 ” touch display for local HMI • Web browser for local and remote access Data logging: • Database for long-term data, alarm and events archival Standards compliance: • EMC immunity/emission : EN 61326-1 (IEC 61326-1:2005), EN 61000-3-2+A1+A2 (IEC 61000-3-2+A1+A2), EN 61000-3-3 (IEC 61000-3-3), EN 61000-4-10+A1 (IEC 61000-4-10+A1), EN 61000-4-12 (IEC 61000-4-12), EN 61000-4-18+A1 (IEC 61000-4-18+A1) • Vibration/shock resistance (EN 60068-2-6/EN 60068-2-27/29) KONČAR – Electrical Engineering Institute Inc. Department for rotating machines Fallerovo šetalište 22, 10 000 Zagreb, Croatia Phone: + 385 1 3656 291 Fax: +385 1 3666 377 Web: www.kon
Open the catalog to page 1Local/remote HMI (real time data, trends, statistics, data analysis ) The AGAP system measures the distance between the stator and the rotor in the machine. Measurement and analysis of the measured results can provide vide range of problems related to alignment, core stability, pole stability, roundness of the rotor and stator, etc. Besides Measurement, and data analysis, AGAP system provides data storage in the database for data comparison and trending. AGAP Features • On-line analysis • Detection of pole movement • Detection of minimum and maximum pole gap • Pole profile plot • Polar plot...
Open the catalog to page 2AGAP specification Architecture: • Data acquisition unit with the real time controller and5,7" touch display Inputs: • One voltage input for stator voltage measurement (0-10 V) (more inputs on request) • One voltage input for key phasor measurement (0-10 V) Communication: • Ethernet 10/100 Power supply: • DC: 80 V to 370 V • AC: 85 to 264 V, frequency 47 to 63 Hz • Maximum allowed power supply interruption: 100 ms for 230 VAC/ 20 ms for 115 VAC • Test voltage: 3 kV (2 kV against ground) Temperature range: • Operational temperature range: -20°C to +70°C (storage temperature: -40° to...
Open the catalog to page 3All KONCAR - Electrical Engineering Institute Inc. catalogs and technical brochures
-
HIGH VOLTAGE LABORATORY
6 Pages
-
Thermo Power Plant Plomin 2
20 Pages
-
Wind turbine KO - VA 57 / 1
2 Pages
-
Wind turbine K80
2 Pages
-
KONCAR-Institute-PECS GUIDE
6 Pages
-
KONCAR-Institute-GRAP IDE
2 Pages