RDT series

RDT series

RDT series

Product catalog summary
MPAC 500 Controller Features:
  • User-friendly interface with international symbols.
  • Indicators for source availability and contactor position.
  • LED indications for system faults such as failure to acquire standby source and failure to transfer.
  • Common fault contact latches closed on system faults.
  • Engine start contact for generator set initiation.
  • Load control contact with a 5-minute startup delay for selected loads.
  • Test and exercise set buttons for weekly generator exercises.
  • Single-phase voltage and frequency sensing with specific tolerances.
  • Fixed time delays for various operations.
Automatic Transfer Switch (ATS) Features:
  • UL listed with models available for different load centers.
  • CSA certification available for specific models.
  • Available in 100, 200, and 400 amp models with selectable voltage and frequency.
  • Two-pole, single-phase open-transition design with solid neutral.
  • Contactor is manually operable for maintenance.
  • Available in NEMA Type 1 and Type 3R enclosures for indoor and outdoor installations.
  • Five-year limited warranty.
Service Entrance Model Features:
  • Available in 200 and 400 amp ratings.
  • Includes service disconnect circuit breaker on the utility source.
  • Enclosure and circuit breaker for generator set battery charger.
Environmental Specifications:
  • Operating temperature: -20°C to 70°C.
  • Storage temperature: -40°C to 85°C.
  • Humidity: 5 to 95% non-condensing.
Contact Ratings:
  • Engine start and common fault contacts with specific ratings.
  • Load control and auxiliary contacts with specified ratings.
Source Sensing and Time Delays:
  • Undervoltage and underfrequency sensing with specific dropout and pickup percentages.
  • Adjustable time delays for engine start, transfer, retransfer, and cooldown.
Cable Sizes:
  • Specifications for wire sizes for different switch ratings and connections.
Contactor Ratings:
  • Withstand current ratings for various manufacturers' circuit breakers.
Service Entrance Transfer Switch Ratings:
  • Factory-equipped with a normal source disconnect circuit breaker.
Codes and Standards:
  • Compliance with UL, CSA, NFPA, IEEE, NEMA, ANSI, and IEC standards.
Weights and Dimensions:
  • Specifications for different enclosure types and models.
Available Accessories:
  • Accessory board, alarm horn, adjustable time delays, inputs and outputs, dip switches, auxiliary contacts, external alarm module, programmable exerciser, wall-mount bezel, load shed kit, and additional accessories for service entrance models.
Model Designation Key:
  • Explanation of the Kohler transfer switch model designation system.
See more

Catalog excerpts

RDT series-1

KOHLER. Power Systems Au,oma,io 1SS3K>5SE: — POWER SYSTEMS NATIONALLY REGISTERED MPAC™ 500 Controller Features • User-friendly interface with easy-to-read international • Source available and contactor position indicators • LED indication of system faults o Failure to acquire standby source o Auxiliary switch fault • Common fault contact: latches closed on system faults shown above • Engine start contact: provides contact closure to start the • Load control contact: allows 5-minute delay in startup of selected loads • Test button (with or without load) o Weekly 20-minute generator set exercise o With or without load • Single-phase voltage sensing on both sources, ±5% • Line-to-line frequency sensing, ±2% • Fixed time delays Standard Features o Models with load centers, UL 67 listed, file #E251086 o Models without load centers, UL 1008 listed, file #E58962 • CSA certification available, file #LR58301 (not applicable to service entrance or load center models) • Two-pole, single-phase open-transition transfer switch • Contactor electrically and mechanically interlocked • Double throw inherently interlocked design • Solid neutral • Contactor manually operable for maintenance purposes • Silver alloy main contacts • All models are 100% equipment rated and can be applied at the rated current without derating • 100 and 200 amp models available with or without prewired Square D type QO load center o 100 amp load center models use up to 16 circuit breakers (up to 8 tandem breakers can be used for a maximum of o 200 amp load center models use up to 24 circuit breakers o 200 amp service entrance model with 42-circuit breaker load center is available o NEMA Type 1 steel ANSI 49 gray enclosure for indoor installation. 100 amp and 200 amp models without load centers can be recess-mounted between wall studs (not service entrance model) o NEMA Type 3R corrosion-resistant aluminum ANSI 49 gray padlockable enclosure. Approved for indoor or outdoor installation • Five-year limited warranty • See page 5 for available accessories Service Entrance Model Features • 200 and 400 amp service entrance rated automatic transfer switches available • Service disconnect circuit breaker on the normal (utility) • NEMA 3R aluminum ANSI 49 gray enclosure • Circuit breaker for generator set battery charger • See page 5 for available SE model accessories G11-98 (Model RDT Automatic Transfer Switch) 6/13m Page 1

 Open the catalog to page 1
RDT series-2

Environmental Specifications Time Delays Operating temperature: Adjustment with Accessory Board* Factory Setting Engine start Transfer from Normal to Emergency Retransfer from Emergency to Normal Engine cooldown 0.5 A @ 125 VAC; 2 A @ 30 VDC SPST normally open (NO) Exercise interval 10 A @ 120 VAC SPST normally open (NO) Load control connection delay Failure to acquire Emergency source Undervoltage dropout Underfrequency dropout Storage temperature: Humidity: Time Delay Contact Ratings Engine start 0.5 A @ 125 VAC; 2 A @ 30 VDC SPST normally closed (NC) Common fault Load control Auxiliary contacts...

 Open the catalog to page 2
RDT series-3

Contactor Ratings with Coordinated Circuit Breakers The transfer switches are UL listed at 240 VAC maximum. The following table lists contactor withstand current ratings (WCR) for 100--400 ampere non-service entrance rated switches with specific manufacturer’s circuit breakers per UL and Canadian safety standards. Suitable for control of motors, electric discharge lamps, tungsten filament lamps and electric heating equipment where the sum of motor full-load ampere ratings and the ampere ratings of other loads do not exceed the ampere rating of the switch and the tungsten load does not exceed...

 Open the catalog to page 3
RDT series-4

Service Entrance Transfer Switch Ratings The service entrance transfer switch is factory-equipped with a normal source disconnect circuit breaker. Switch Rating, Amps Codes and Standards The ATS meets or exceeds the requirements of the following specifications: D Underwriters Laboratories UL 67, Enclosed Panel Boards (load center models) file # E251086 D Underwriters Laboratories UL 1008, Standard for Automatic Transfer Switches for Use in Emergency Systems, file # E58962 D Underwriters Laboratories UL 508, Standard for Industrial Control Equipment D CSA certified, file # LR58301 (not applicable...

 Open the catalog to page 4
RDT series-5

Available Accessories - Load shed kit - Accessory board D Alarm horn indicates system faults D Adjustable time delays: d d d d d Engine start Engine cooldown Preferred to standby Standby to preferred Exercise duration D Inputs and Outputs: d Remote start/stop input (loaded) d Programmable exerciser input d Generator set supplying load output: 10 A @ 120 V SPST normally open (NO) contact D External alarm module connection D Dip switches: d 1 week/2 week exerciser d Load/no load exercise mode (for optional programmable exerciser) d Momentary/maintained external start/stop input: Selects momentary...

 Open the catalog to page 5
RDT series-6

KOHLER CO., Kohler, Wisconsin 53044 USA Phone 920-457-4441, Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada, phone 1-800-544-2444 KOHLERPower.com Model Mechanism Transition Kohler Power Systems Asia Pacific Headquarters 7 Jurong Pier Road Singapore 619159 Phone (65) 6264-6422, Fax (65) 6264-6455 Current Rating Kohlerr Model Designation Key This chart explains the Kohlerr transfer switch model designation system. The sample model designation shown is for a Model R service entrance rated automatic transfer switch that uses a standard-transition contactor with MPACt...