video corpo

NFPA 110

NFPA 110

NFPA 110

Product catalog summary
Overview: This document outlines the compliance of KOHLER generators and transfer switches with NFPA 110 standards, focusing on key components such as battery chargers, remote serial annunciators, controllers, and fuel tanks.
Specifications: KOHLER generators and transfer switches are designed to meet NFPA 110 requirements when equipped with necessary accessories and installed according to the standard. This includes aspects like mounting, cooling, starting, load switching, and voltage regulation.
Battery Chargers: NFPA 110 specifies requirements for battery charging, including monitoring output voltage and current. KOHLER's 10-amp battery charger meets these requirements and can indicate low/high battery voltage and charger faults, depending on the power system level.
Remote Serial Annunciators: For NFPA 110 Level 1, generator conditions must be annunciated at a continuously staffed location. KOHLER's remote serial annunciators provide this functionality, with options to include automatic transfer switch (ATS) information, allowing for remote testing and status updates of power sources and switch positions.
Decision-Maker Controllers: These controllers comply with NFPA 110 Level 1 and feature emergency stop, stop/run/auto controls, audible and visual warnings, and fault indicators. They monitor and annunciate system faults and status on both the controller display and remote annunciator.
Fuel Tanks: KOHLER offers fuel tanks that meet NFPA 110 class definitions, determining the power system classification and minimum operational time without refueling. The generator's load rating and required runtime, along with other NFPA 100 requirements, dictate the fuel tank size.
Additional Information: For more details, visit KohlerPower.com or call 800-544-2444.
See more

Catalog excerpts

NFPA 110-2

PRODUCTS KOHLER GENERATORS AND TRANSFER SWITCHES ® NFPA 110 requirements cover functions such as mounting, cooling, starting, load switching and voltage regulation. KOHLER generators and automatic transfer switches are designed to meet NFPA 110 when equipped with the required accessories and installed per the standard. FUEL TANKS Kohler offers a range of fuel tank options to meet the NFPA 110 “class” definition, which sets forth the classification of the power system and the minimum time (in hours) that such power system must be designed to operate at its rated load without being refueled, and...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.