8RESVL-1

Standard Features D DC2 Controller d One digital controller manages both the generator set and Model RXT transfer switch functions d Designed for today’s most sophisticated electronics. d Electronic speed control responds quickly to varying household demand. d Digital voltage regulation protects your sensitive electronics from harmonic distortion and unstable power quality. d Two-line, backlit LCD display with adjustable contrast is easy to read, even in direct sunlight or low light. d OnCuer Plus Generator Management System for remote monitoring is included with every generator. D Kohler Engine Features d Kohler engine with efficient OHV design d Powerful, reliable air-cooled performance d Simple field conversion between natural gas and LPG fuels while maintaining emission certification D High Quality Power Kohler home generators provide advanced voltage and frequency regulation along with ultra-low levels of harmonic distortion for excellent generator power quality to protect your valuable electronics. Kohler is known for extraordinary reliability and performance and backs that up with a 5-year or 2000 hour limited warranty. Exclusive Powerboostt technology provides excellent starting power. The Kohler 8 kW generator can easily start and run a 4 ton air conditioner with up to 5 kW preload.* Bold new Kohler design in steel, dipped in e-coat for extra corrosion protection and painted with a durable powder coat finish. Kohler home generators provide quiet, neighborhoodfriendly performance. D Designed for Easy Installation d Steel base d Hinged, locking roof d Fuel and electrical connections through the enclosure wall eliminate the need for stub-ups through the bottom d Accepts natural gas fuel pressure as low as 3.5 inches d Load connection terminal block allows easy field wiring d Designed for outdoor installation only D Approved for stationary standby applications in locations served by a reliable utility source D Model RXT Transfer Switch d 100 amp ATS w/NEMA 1 enclosure with 12-space load center for indoor installation is included d See page 4 for additional information D Meets 181 mph wind rating D Certifications d Meets emission regulations for U.S. Environmental Protection Agency (EPA) 40 CFR 60 stationary source standards with both LPG and natural gas. Note: CARB does not regulate emergency standby generators outputting less than 50 HP. Only the EPA standards apply. d UL 2200 listed (60 Hz model) d Accepted by the Massachusetts Board of Registration of Plumbers and Gas Fitters. Generator Ratings Model 8RESVL Standby Ratings Natural Gas LPG kW/kVA Amps kW/kVA 7/7 29.2 8/8 RATINGS: Standby ratings apply to installations served by a reliable utility source. All single-phase units are rated at 1.0 power factor. The standby rating is applicable to variable loads with an average load factor of 80% for the duration of the power outage. No overload capacity is specified at this rating. Ratings are in accordance with ISO--3046/1, BS5514, AS2789, and DIN 6271. GENERAL GUIDELINES FOR DERATING: ALTITUDE: Derate 4% per 305 m (1000 ft.) elevation above 153 m (500 ft.). TEMPERATURE: Derate 2% per 5.5_C (10_F) temperature increase above 16_C (60_F). Availability is subject to change without notice. The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Contact your local Kohler Co. generator distributor for availability. * Check the appliance manufacturer’s specifications for actual power requirements. Consult a Kohlerr Power Systems professional to calculate your exact residential power system requirements. G4-240 (8RESVL) 10/14b

 Open the catalog to page 1
8RESVL-2

Alternator Specifications Alternator Specifications Alternator Features PowerBoostt Generator 1-Phase Specifications Manufacturer Output reconnectable Type D Windings are vacuum-impregnated with epoxy varnish for dependability and long life. Voltage regulator D Superior voltage waveform and minimum harmonic distortion from skewed alternator construction Material Temperature rise D Digital voltage regulator with 1.0% no-load to full-load Bearing: quantity, type Coupling D Rotating-field alternator with static exciter for excellent load response Amortisseur windings Voltage regulation, no-load...

 Open the catalog to page 2
8RESVL-3

Fuel Requirements Fuel System Fuel types Fuel supply inlet Fuel supply pressure, kPa (in. H2O): Natural gas Fuel Composition Limits * Methane, % by volume (minimum) Ethane, % by volume (maximum) Propane, % by volume Propene, % by volume (maximum) C4 and higher, % by volume Sulfur, ppm mass (maximum) Lower heating value, MJ/m3 (Btu/ft3), (minimum) 33.2 (890) 84.2 (2260) * Contact your local distributor for suitability and rating derates based on fuel compositions outside these limits. Fuel Consumption, D LCD screen d Two lines x 16 characters per line d Backlit display with adjustable contrast...

 Open the catalog to page 3
8RESVL-4

Kohler Power Systems Asia Pacific Headquarters 7 Jurong Pier Road Singapore 619159 Phone (65) 6264-6422, Fax (65) 6264-6455 KOHLER CO., Kohler, Wisconsin 53044 USA Phone 920-457-4441, Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada, phone 1-800-544-2444 KOHLERPower.com Generator Set Standard Features Available Accessories, Continued D ATS: Model RXT automatic transfer switch with indoor enclosure and 12-circuit load center D Battery cables D Braided stainless steel flexible fuel line D Critical silencer D DC2 generator set/ATS controller D EPA certified fuel system...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.