Standard Features D Kohler Co. provides one-source responsibility for the generating system and accessories. D The generator set and its components are prototype-tested, factory-built, and production-tested. D The generator set is CSA certified, file # LR 955. D UL 2200 listing is available. D The generator set engine complies with Environmental Protection Agency (EPA) emergency stationary emissions requirements. D The generator set meets NFPA 110, Level 1, when equipped with the necessary accessories and installed per NFPA standards. D A one-year limited warranty covers all systems and components. Two- and five-year extended warranties are also available. D Four-point mounting with vibration isolators. D The brushless, rotating-field alternator has broadrange reconnectability. D Voltage regulation of ±0.25%. D Sustained short-circuit capability. D Customer connection box with field-connection terminal blocks. D Single-side access. D Weather and sound enclosures are available. d Enclosures reduce sound levels and protect the generator set from the elements, animal intrusion, and unwanted entry. d Enclosures have a fade-, scratch-, and corrosionresistant Kohlerr Power Armortcream beige automotive-grade textured finish and lockable, flushmounted door latches. d See specification sheet G6-96 for enclosure features and specifications. Shown with available subbase fuel tank. Generator Set Ratings 130 _C Rise Standby Rating 105 _C Rise Prime Rating RATINGS: All three-phase units are rated at 0.8 power factor. Standby Ratings: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046/1, BS 5514, AS 2789, and DIN 6271. Prime Power Ratings: Prime power ratings apply to installations where utility power is unavailable or unreliable. At varying load, the number of generator set operating hours is unlimited. A 10% overload capacity is available for one hour in twelve. Ratings are in accordance with ISO-8528/1, overload power in accordance with ISO-3046/1, BS 5514, AS 2789, and DIN 6271. For limited running time and base load ratings, consult the factory. Obtain the technical information bulletin (TIB-101) on ratings guidelines for the complete ratings definitions. The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Contact your local Kohlerr generator set distributor for availability. GENERAL GUIDELINES FOR DERATING: ALTITUDE: Derate 0.8% per 100 m (328 ft.) elevation above 200 m (656 ft.). TEMPERATURE: Derate 6.0% per 10_C (18_F) temperature above 25_C (77_F).
Open the catalog to page 1Alternator Specifications Exciter type Leads: quantity, type Voltage regulator Solid State Temperature rise in 25°C ambient 130°C Coupling Flexible Disc Amortisseur windings Full Voltage regulation, no-load to full-load ±0.25% One-step load acceptance 100% of Rating Peak motor starting kVA (35% dip for voltages below): • NEMA MG1, IEEE, and ANSI standards compliance for temperature rise and motor starting. • Sustained short-circuit current of up to 300% of the rated • Sustained short-circuit current enabling downstream circuit breakers to trip without collapsing the alternator field. • Self-ventilated...
Open the catalog to page 2Application Data Ambient temperature, °C(°F) 50 (122) * Type Liquid Capacity, engine only, L (qt.) 2.7 (2.8) Engine jacket water flow, Lpm (gpm) 33.0 (8.7) Capacity with unit-mounted radiator, L (qt.) 9.3 (9.8) Heat rejected to cooling water at rated kW, Fan diameter, unit-mounted radiator, Max. restriction of cooling air, intake and discharge side of radiator, kPa (in. H20) 0.125 (0.5) * Enclosure with enclosed silencer reduces ambient Remote Radiator System" 60 Hz Exhaust manifold type Dry Connection sizes Static head, maximum, m (ft.) 4(13.1) t Contact your local distributor for cooling system...
Open the catalog to page 3Kohler Power Systems Asia Pacific Headquarters 7 Jurong Pier Road Singapore 619159 Phone (65) 6264-6422, Fax (65) 6264-6455 KOHLER CO., Kohler, Wisconsin 53044 USA Phone 920-457-4441, Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada, phone 1-800-544-2444 KOHLERPower.com Additional Standard Features D D D D D Battery Rack and Cables Decision-Makerr 3000 Controller Fuel/Water Separator Oil Drain Extension Oil Pressure Sender - General Maintenance Literature Kit - NFPA 110 Literature Kit - Overhaul Literature Kit - Production Literature Kit Warranty Available Accessories...
Open the catalog to page 44 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
32 Pages
12 Pages
2 Pages
6 Pages
24 Pages
8 Pages
8 Pages
24 Pages
4 Pages
2 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
6 Pages
6 Pages
4 Pages
4 Pages
16 Pages
2 Pages
2 Pages
4 Pages
4 Pages
8 Pages
4 Pages
8 Pages
12 Pages
4 Pages
4 Pages