KOHLER. Power Systems NATIONALLY REGISTERED Stationary Emergency Ratings Range Standby Rating Prime Rating Voltage Ph Hz kW/kVA Amps kW/kVA Amps Standard Features • Kohler Co. provides one-source responsibility for the generating system and accessories. prototype-tested, factory-built, and production-tested. • The 60 Hz generator set offers a UL 2200 listing. • The generator set accepts rated load in one step. • The 60 Hz generator set meets NFPA 110, Level 1, when equipped with the necessary accessories and installed per NFPA standards. • A one-year limited warranty covers all systems and components. Two- and five-year extended warranties • Alternator features: o The unique Fast-Response™ X excitation system delivers excellent voltage response and short-circuit capability using a rare-earth, permanent magnet (PM)-excited alternator. o The unique Fast-Response™ II excitation system delivers excellent voltage response and short-circuit capability using a permanent magnet (PM)-excited o The brushless, rotating-field alternator has broadrange reconnectability. • Other features: o Kohler designed controllers for guaranteed system integration and remote communication. See o The low coolant level shutdown prevents overheating (standard on radiator models only). o Integral vibration isolation eliminates the need for under-unit vibration spring isolators. o Multiple circuit breaker configurations. RATINGS: All three-phase units are rated at 0.8 power factor. All single-phase units are rated at 1.0 power factor. Standby Ratings: The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Prime Power Ratings: At varying load, the number of generator set operating hours is unlimited. A10% overload capacity is available for one hour in twelve. Ratings are in accordance with ISO-8528-1 and ISO-3046-1. For limited running time and continuous ratings, consult the factory. Obtain technical information bulletin (TIB-101) for ratings guidelines, complete ratings definitions, and site condition derates. The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever.
Open the catalog to page 1Alternator Specifications D NEMA MG1, IEEE, and ANSI standards compliance for temperature rise and motor starting. Specifications Manufacturer Type Alternator Kohler 4-Pole, Rotating-Field Exciter type Leads: quantity, type 4SX, 4UA Voltage regulator Insulation: Material Temperature rise Bearing: quantity, type Coupling Amortisseur windings Voltage regulation, no-load to full-load Brushless, Permanent-Magnet One-step load acceptance Unbalanced load capability D Sustained short-circuit current of up to 300% of the rated current for up to 10 seconds. D Sustained short-circuit current enabling downstream...
Open the catalog to page 2Application Data Cooling Radiator System Ambient temperature, _C (_F) * Engine jacket water capacity, L (gal.) Radiator system capacity, including engine, L (gal.) Engine jacket water flow, Lpm (gpm) Heat rejected to cooling water at rated kW, dry exhaust, kW (Btu/min.) Heat rejected to air charge cooler at rated kW, dry exhaust, kW (Btu/min.) Water pump type Fan diameter, including blades, mm (in.) Max. restriction of cooling air, intake and discharge side of radiator, kPa (in. H2O) * Enclosure with enclosed silencer reduces ambient temperature capability by 5°C (9°F). Decision-Makerr 3000 Controller...
Open the catalog to page 3Kohler Power Systems Asia Pacific Headquarters 7 Jurong Pier Road Singapore 619159 Phone (65) 6264-6422, Fax (65) 6264-6455 KOHLER CO., Kohler, Wisconsin 53044 USA Phone 920-457-4441, Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada, phone 1-800-544-2444 KOHLERPower.com Standard Features - Miscellaneous Air Cleaner, Heavy Duty Air Cleaner Restriction Indicator Certified Test Report Crankcase Emissions Canister Engine Fluids Added Rated Power Factor Testing Rodent Guards D Alternator Protection D Battery Rack and Cables D Customer Connection (standard with Decision-Makerr...
Open the catalog to page 44 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
32 Pages
12 Pages
2 Pages
6 Pages
24 Pages
8 Pages
8 Pages
24 Pages
4 Pages
2 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
6 Pages
6 Pages
4 Pages
4 Pages
16 Pages
2 Pages
2 Pages
4 Pages
4 Pages
8 Pages
4 Pages
8 Pages
12 Pages
4 Pages
4 Pages