180 REOZJG - 1

190-600 V Tier 3 EPA-Certified for Stationary Emergency Applications Ratings Range Standby: Prime: Generator Set Ratings Alternator Standard Features D Kohler Co. provides one-source responsibility for the generating system and accessories. D The generator set and its components are prototype-tested, factory-built, and production-tested. D The 60 Hz generator set offers a UL 2200 listing. D The generator set accepts rated load in one step. D The 60 Hz generator set meets NFPA 110, Level 1, when equipped with the necessary accessories and installed per NFPA standards. D A one-year limited warranty covers all systems and components. Two- and five-year extended warranties are also available. D Alternator features: d The unique Fast-Responset X excitation system delivers excellent voltage response and short-circuit capability using a rare-earth, permanent magnet (PM)-excited alternator. d The brushless, rotating-field alternator has broadrange reconnectability. D Other features: d Kohler designed controllers for guaranteed system integration and remote communication. See Controllers on page 3. d The low coolant level shutdown prevents overheating (standard on radiator models only). d Integral vibration isolation eliminates the need for under-unit vibration spring isolators. d Multiple circuit breaker configurations. RATINGS: All three-phase units are rated at 0.8 power factor. All single-phase units are rated at 1.0 power factor. Standby Ratings: The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Prime Power Ratings: At varying load, the number of generator set operating hours is unlimited. A 10% overload capacity is available for one hour in twelve. Ratings are in accordance with ISO-8528-1 and ISO-3046-1. For limited running time and continuous ratings, consult the factory. Obtain technical information bulletin (TIB-101) for ratings guidelines, complete ratings definitions, and site condition derates. The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. G5-401 (180REOZJG) 8/12a

Open the catalog to page 1
180 REOZJG - 2

Alternator Specifications Specifications Manufacturer Type Exciter type Leads: quantity, type Voltage regulator Insulation: Material Temperature rise Bearing: quantity, type Coupling Amortisseur windings Voltage regulation, no-load to full-load One-step load acceptance Unbalanced load capability Peak motor starting kVA: 480 V, 380 V 4S12X (12 lead) 480 V, 380 V 4S13X (12 lead) Alternator Kohler 4-Pole, Rotating-Field Brushless, Rare-Earth Permanent-Magnet 12, Reconnectable Solid State, Volts/Hz NEMA MG1 Class H 130_C, Standby 1, Sealed Flexible Disc Full Controller Dependent 100% of Rating...

Open the catalog to page 2
180 REOZJG - 3

Application Data Radiator System Engine jacket water capacity, L (gal.) Radiator system capacity, including Engine jacket water flow, Lpm (gpm) Heat rejected to cooling water at rated Heat rejected to air charge cooler at rated kW, dry exhaust, kW (Btu/min.) Water pump type Fan diameter, including blades, mm (in.) Max. restriction of cooling air, intake and discharge side of radiator, kPa (in. H20) * Enclosure with enclosed silencer reduces ambient Operation Requirements_ Heat rejected to ambient air: Fuel Consumption Standby Rating Prime Rating Provides advanced control, system monitoring,...

Open the catalog to page 3
180 REOZJG - 4

Kohler Power Systems Asia Pacific Headquarters 7 Jurong Pier Road Singapore 619159 Phone (65) 6264-6422, Fax (65) 6264-6455 KOHLER CO., Kohler, Wisconsin 53044 USA Phone 920-457-4441, Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada, phone 1-800-544-2444 KohlerPower.com Standard Features - Available Options Approvals and Listings - CSA Approval - UL 2200 Listing Enclosed Unit - Sound Enclosure (with enclosed critical silencer) - Weather Enclosure (with enclosed critical silencer) Fuel System - Flexible Fuel Lines - Fuel Pressure Gauge - Subbase Fuel Tanks...

Open the catalog to page 4

All KOHLER POWER SYSTEMS catalogs and technical brochures

  1. 33EFOZCJ

    4 Pages

  2. 13.5EFKOZD

    4 Pages

  3. 9EFKOZD

    4 Pages

  4. 5EFKOD

    4 Pages

  5. 200EOZDJ

    4 Pages

  6. Gas_Generators

    12 Pages

  7. NFPA 110

    2 Pages

  8. Power armor

    6 Pages

  9. 8RESVL

    4 Pages

  10. 400REOZJ

    4 Pages

  11. 200 REOZJ F

    4 Pages

  12. 20REOZDC

    4 Pages

  13. 40EORZDB

    4 Pages

  14. RXT series

    6 Pages

  15. RDT series

    6 Pages