Generator Weights and Dimensions Without With Sound Shield Sound Shield Weight, kg (lb.) Wet Dry Length, mm (in.) Width, mm (in.) Height, mm (in.) Generator Ratings (Alternator) Voltage Hz Amps kW/kVA Ph RATINGS: Marine continuous ratings per ISO 3046, ISO 8528-1, and Kohler technical information bulletin TIB-117. Obtain technical information bulletin (TIB-101)on ratings guidelines for complete ratings definitions. Availabilityissubjecttochangewithoutnotice.KohlerCo.reservestherighttochangethedesignor specifications without notice and without any obligation or liability whatsoever. Contact your local Kohler generator distributor for availability. Marine Generator Set Engine Features • Diesel fueled • Certified by the Environmental Protection Agency (EPA) to conform to Tier III marine auxiliary standards (60 Hz model only) • Three cylinder • Four cycle • Closed cooling system • Heat exchanger • Electric fuel lift pump • Lifting eye Generator Features • Class H insulation • Multivoltage adjustability • Voltage regulation of ±1.0% • Radio suppression Decision-Maker® 3500 Paralleling Controller • A graphical display and pushbutton/rotary selector dial provide easy, local data access • Measurements are selectable in metric or English units • The controller supports Modbus® protocol with serial bus (RS-485) or Ethernet networks • Scrolling display shows critical data at a glance • Graphical display of power metering (kW, kVA, V, I, PF, and VAR) • Integrated hybrid voltage regulator providing ±0.5% regulation • Built-in alternator thermal overload protection Optional Accessories • Aluminum sound shield • Remote digital gauge • Remote digital display • Siphon break • Circuit breakers Modbus® is a registered trademark of Schneider Electric.
Open the catalog to page 1Engine Electrical Engine Electrical System Battery, voltage Battery charging module Battery, minimum recommendation Starter motor Engine combustion air requirements, L/min. (cfm) Generator cooling requirements, L/min. (cfm) Max. air intake restriction, kPa (in. H2O) Exhaust flow, m3/min. (cfm) Exhaust temp., °C (°F) at full load Max. allowed exhaust back pressure, kPa (in. H2O) Fuel Consumption Note: The fuel consumption of the 60 Hz model is based 16EKOZD and the fuel consumption of the 50 Hz model 13.5EFKOZD. Cooling Cooling System Capacity, L (qt.), approx. Heat exchanger type Seawater pump...
Open the catalog to page 2Decision-Maker® 3500 Controller Provides advanced control, system monitoring, and system diagnostics for optimum performance and compatibility. The Decision-Maker® 3500 controller uses a patented hybrid voltage regulator and unique software logic to manage alternator thermal overload protection features normally requiring additional hardware. Additional features include: • AC Output Voltage Regulator Adjustment. The voltage adjustment provides a maximum adjustment of ± 10% of the system voltage. • Alarm Silence. The controller can be set up to silence the alarm horn only when in the AUTO mode...
Open the catalog to page 3KOHLER CO., Kohler, Wisconsin 53044 USA Phone 920-457-4441, Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada, phone 1-800-544-2444 KOHLERPower.com Note: Sound shield shown with rear connection panel. Front connection panel is also available. DISTRIBUTED BY: NOTE: Dimensions are shown in mm [in.]. NOTE: This drawing is provided for reference only and is not intended for installation planning. Contact your local distributor for more detailed information. E 2016 and 2017 by Kohler Co. All rights reserved. G2-187 (16EKOZD 1 PH) 3/17b
Open the catalog to page 44 Pages
4 Pages
4 Pages
4 Pages
2 Pages
32 Pages
12 Pages
2 Pages
6 Pages
24 Pages
8 Pages
8 Pages
24 Pages
4 Pages
2 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
6 Pages
6 Pages
4 Pages
4 Pages
16 Pages
2 Pages
2 Pages
4 Pages
4 Pages
8 Pages
4 Pages
8 Pages
12 Pages
4 Pages
4 Pages