General Description
EPPE PX is a portable, high-precision power quality analyser with an integrated fault recorder, housed in a rugged carrying case. It features sensor inputs, direct current measurement inputs, and galvanically isolated voltage inputs for flexible use.

Multi-Processor System
The device includes a 32-bit, 330 MHz digital signal processor for real-time signal processing and a dual-core 32-bit, 1 GHz communication processor for mass data storage and communication.

User Controls and Displays
Features include 5 status LEDs, a 7" color graphical display with touch screen, and 4 function keys.

Data Memory
4 GB flash RAM for measurement data and 512 MB for firmware.

Calibration
Software-controlled calibration with a recommended cycle of every 5 years.

Operating Software
Compatible with Windows 7, 8.1, and 10 (32 and 64 bit).

Function Overview
Includes power quality analysis, continuous and event data recording, digital and RMS fault recording, sensor recording, and energy metering.

Standards for Measurement and Analysis
Complies with IEC 61000-4-30 class A, IEC 61000-4-7, IEC 61000-4-15, EN 50160, IEEE 519, and IEEE 1159.

Analog Inputs
Features 16-bit resolution, 200 kHz sampling frequency, and 0.05% accuracy. Voltage inputs have a range of 600 VAC/±848 VDC, and current inputs have a range of 32 AAC.

Current Sensor Inputs
Includes 4 inputs with a measuring range of 3 V and a frequency range of DC to 10 kHz.

Measurement Connections
Utilizes 4 mm safety sockets and multi-pole system sockets.

Temperature Input
One input with a Pt 1000 sensor type, measuring range of -20°C to 80°C.

Analog Output
One output with a range of 0 to 10 VDC.

Binary Inputs and Outputs
Includes 8 binary inputs with transient and polarity protection, and 2 relay outputs for status and alarm signals.

Time Synchronisation
Features an internal real-time clock, NTP/SNTP synchronisation, and an internal GPS receiver.

Interfaces
Includes Ethernet, USB-A, USB-B, and interlink interfaces for device networking.

Power Supply
External power supply unit with 100-240 VAC input and internal emergency power supply.

Mechanical Properties
Weighs 5.8 kg, housed in a waterproof polycarbonate case with IP 65 protection.

Environmental Conditions
Storage temperature range of -20 to 70°C, operating temperature range of -5 to 50°C, and relative humidity of 5 to 90% non-condensing.

Generic Standards
Complies with safety standard EN 61010-1 and EMC standards EN 61000-6-4 and EN 61000-6-2.
See more

Catalog excerpts

 EPPE PX Specifications -1

Multi-processor Digital signal processor (DSP), 32 bit, 330 MHz system for processing signals and processes in real time Communication processor, dual-core 32 bit, 1 GHz for mass data storage, simultaneous data communication using different interfaces, web server functionality and stand-alone operation User controls and 5 status LEDs for trigger and status display displays 7" colour graphical display with touch screen and 4 function keys Data memory 4 GB flash RAM for measurement data 512 MB flash RAM for firmware Calibration Software-controlled calibration Recommended calibration cycle: check every 5 years Operating EPPE operating software for Windows 7, 8.1, 10 (32 and 64 bit) Function Recording Power quality analyser, class A overview functions Continuous data recording Event data recording Standards for measurement and analysis Analog inputs General Digital fault recorder, sampling rate from 100 Hz...30 kHz RMS fault recorder, sampling rate from 1 Hz...120 Hz Sensor recording Energy meter Logical functions IEC 61000-4-30 class A IEC 61000-4-7 harmonics and interharmonics IEC 61000-4-15 flicker EN 50160, IEEE 519, IEEE 1159 Resolution 16 bit Sampling frequency 200 kHz per channel (physical) Protection Galvanic isolation, Ph-PE > 2.5 kV RMS Voltage inputs Number 4 Current inputs Number 4 Technical specifications subject to change without prior notice | ©08/2016 KoCoS Messtechnik AG www.kocos.com Doc. 7615200 Rev. 1.30

 Open the catalog to page 1
 EPPE PX Specifications -2

Current sensor Number 4 Measurement 4 mm safety sockets and multi-pole system sockets connections Sensor inputs Number 4, sampling frequency 10 kHz Temperature Number 1, sampling frequency 100 Hz input Sensor type Pt 1000 Analog output Binary inputs Number 8 (2 groups with separate reference points) Activation range 24.300 VDC (wide-range inputs) Protection Transient protection, polarity protection, Binary 0utputs Relays Number 2, configurable for status and alarm signals Contact type Potential-free relay contact as NO contact Switching capacity Max. 220 VDC, 2 ADC, 60 W resistive load Standard...

 Open the catalog to page 2

All KoCoS Messtechnik AG catalogs and technical brochures

  1. LOTOS Flyer

    2  Pages

  2. INDEC Brochure

    16  Pages

  3. INDEC VD 400

    2  Pages

  4. ARTES 500

    2  Pages

  5. OMCAT Series

    12  Pages

  6. LOTOS LT

    2  Pages

  7. INDEC

    2  Pages

  8. PROMET L100s

    2  Pages

  9. PROMET L10

    2  Pages

  10. PROMET R300

    2  Pages

  11. ACTAS BTT 2.0

    2  Pages

  12. EPOS MC4

    2  Pages

  13. EPOS 360

    2  Pages

  14. ACTAS P360+

    2  Pages

  15. ARTES 600

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.