Multi-Cell™

Multi-Cell™

Multi-Cell™

Product catalog summary
Overview: The Koch Multi-Cell air filters are designed for high efficiency and extended surface applications in HVAC systems. They are particularly suitable for Variable Air Volume (VAV) systems and environments requiring robust filter strength and reliability.
Specifications: Multi-Cell filters are available in three efficiency ranges (60-65%, 80-85%, and 90-95%) and multiple standard face sizes. They come in two depths and five frame and header styles to fit various filtration systems. The filters are constructed with either galvanized steel or particle board, depending on the style, and are rated for temperatures up to 180°F.
Styles:
  • Style FM: Galvanized steel sides, single header, UL Class 1.
  • Style NHM: Galvanized steel sides, no header, UL Class 1.
  • Style SBM: Galvanized steel sides, double header, UL Class 1.
  • Style FW: Particle board sides, single header, UL Class 2.
  • Style SBW: Particle board sides, no header, UL Class 2.
High Temperature Applications: Multi-Cell HT filters are designed for high-temperature environments (750°F to 900°F) and are constructed with aluminized steel frames. They are suitable for use in paint ovens and come with aluminized steel faceguards for protection.
Construction Features: The filters use glass fiber media formed into a micro-glass paper mat, with corrugated aluminum separators for media spacing and strength. Sealants vary by model, with thermoplastic hot-melt adhesive for galvanized steel models and polyurethane for particle board models.
Performance Data: The filters are tested according to ASHRAE standards 52.1 and 52.2. They can operate up to 125% of rated face velocity and are available in high capacity configurations with 30% more media area for extended service life.
Operational Data: The document provides detailed operational data for various models, including nominal sizes, rated air flow capacity, initial and recommended final resistance, and media area.
Additional Features: Optional features include protective faceguards, gaskets for different housing types, and antimicrobial-treated filter media.
See more

Catalog excerpts

Multi-Cell™-1

Koch Filter Corporation Filtration Products Crafted with Pride Medium and High Efficiency Extended Surface Air Filters • Three efficiency ranges • Multiple frame and header options • Designed for Variable Air Volume systems

 Open the catalog to page 1
Multi-Cell™-2

Multi-Cell Medium and High Efficiency Extended Surface Air Filters The Koch Multi -Cell is a high efficiency, extended surface air filter designed for use in HVAC applications of all types. Rigid construction makes the Multi-Cell a superior filter in variable-airvolume (VAV) systems, or in any application where extreme conditions require additional filter strength and reliability. To meet the requirements of various filtration systems, Multi-Cells are offered in multiple standard face sizes, two depths, and three different efficiencies. Five unique frame and header styles are available to insure...

 Open the catalog to page 2
Multi-Cell™-3

Multi-Cell Construction Cell Sides on Styles FM, NHM and SBM are constructed with heavy-duty galvanized steel. Styles SBW and FW are constructed with 3/4” Particle Board. Header on Models FM, SBM, and FW is constructed with galvanized steel for problem-free installation into the filter housing. Filter Media is produced from glass fibers and is formed into a durable, graded-density micro-glass paper mat. Corrugated aluminum separators provide proper media spacing and additional strength to the media pack. Each separator is folded on the leading edge to make it twice as durable and to prevent damage...

 Open the catalog to page 3
Multi-Cell™-4

Multi-Cell Operational Data Multi-Cell Operational Data Model No.1 Recommended Final Resistance (in W.G.) Multi-Cell Operational Data is based on ASHRAE Test Standard 52.1 and 52.2. Media area will vary slightly depending on the header configuration. A) Standard Multi-Cells may be installed with pleats vertical or horizontal. Multi-Cell HT should be installed with pleats vertical. B) Standard header thickness on Styles FM, SBM and FW is 13/16”. 1-1/8” thickness is available if required. Sizes listed above are nominal. Actual sizes are: a) Nominal 12” units – Less 5/8” on height & width and less...

 Open the catalog to page 4

All Koch Filter Corporation catalogs and technical brochures

  1. Maxi-Cell™

    2  Pages

  2. BioMAX™

    2  Pages

  3. Multi-Cell™

    2  Pages

  4. KDF 600

    1  Page

  5. Maxi-Grid

    2  Pages

  6. OdorKleen250

    2  Pages

  7. Multi-45

    1  Page

  8. MicroMAXPL6

    2  Pages

  9. KDF600

    1  Page

  10. DuoCap

    1  Page

  11. DuraMAX4v32

    1  Page

  12. BioMAX HEPA

    2  Pages

  13. BioMAX V2000

    1  Page

  14. HogsHair

    1  Page

  15. DuraPURE

    2  Pages

  16. DuraMAX 4vS

    1  Page

  17. DuraMAX2vS

    1  Page

  18. Duo-Pak 40

    1  Page

  19. SprayStop FG

    1  Page

  20. SprayStop HCX

    2  Pages

  21. MicroMAX™

    4  Pages

  22. Multi-Flo™

    2  Pages

  23. Multi-Sak™

    6  Pages

  24. Koch ICF

    2  Pages

  25. Maxi-Grid?

    6  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.