DMH
7Pages

{{requestButtons}}

Catalog excerpts

DMH - 1

Electromagnetic Flowmeter Accuracy: ± 0.3% of reading ± 0.01% x Qmax C onnection: flange DN 10 ... 1200, ANSI ½" ... 48" Lining material: hard rubber, soft rubber, PTFE / PFA Outputs: analogue with HART®, pulses and status OO KOBOLD companies worldwide: ARGENTINA, AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLoMBIA, CZECHIA, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, Republic of Korea, ROMANIA, SINGAPORE, SPAIN, SWITZERLAND, TAIWAN, THAILAND, TUNISIA, turkey, USA, VIETNAM KOBOLD Messring GmbH Nordring 22-24 D-65719 Hofheim/Ts. Head Office: +49(0)6192 299-0 +49(0)6192 23398 info.d

Open the catalog to page 1
DMH - 2

Electromagnetic Flowmeter Model DMH Description The KOBOLD DMH flowmeter is used to measure and monitor the volume flow rate of fluids, pulps, pastes and other electrically conductive materials, without loss of pressure. When an electrically conductive medium passes through a directional magnetic field, a voltage is induced in accordance with Faraday’s Law of Induction. The size of this measurement voltage is proportional to the mean rate of flow and consequently also to the volume flow rate. A flowmeter consists of a sensor that picks up the measuring signal generated from the induced...

Open the catalog to page 2
DMH - 3

Electromagnetic Flowmeter Model DMH Technical Details(continued) Transducer UMF2(B) Assembly type: compact or separate Housing: enamelled die-cast aluminium Power supply: 115 VAC, 50 / 60 Hz, 10 VA 230 VAC, 50 / 60 Hz, 10 VA 24 VDC 10 W Outputs Analogue: x 0(4)-20 mA, active, galvanically 1 isolated Pulse output: passive, galvanically isolated 24 V, 60 mA Status: passive, galvanically isolated 24 V, 60 mA Ambient temperature: -20 … +60  °C, depending on process temperature for compact version Protection type: IP 68 (EN60529) Communication: HART® Diagnosis functions: empty pipe recognition,...

Open the catalog to page 3
DMH - 4

Electromagnetic Flowmeter Model DMH No responsibility taken for errors; subject to change without prior notice.

Open the catalog to page 4
DMH - 5

Electromagnetic Flowmeter Model DMH Order Details (Example: DMH-1 A15 H 1 0 A 1 0) Model/ flangematerial Versions/ cable lengths Power supply/ cable entry point A = compact, IP 67 B ... H, IP 67 B = separate version/2.5 m C = eparate s version/5 m D = eparate s version/10 m E = separate version/15 m H6) = hard rubber W6) = soft rubber T7) = PTFE/ PFA F = separate 08) = without version/ 20 m 1 = UMF2(B)1 = stainless electronics 1 = stainless G = separate steel with control steel version/ 30 m unit, without 3 = HastelHART® H = eparate s loy® C4 3 = Hastelloy® C4 version/ 50 m 2 = UMF2(B)4 =...

Open the catalog to page 5
DMH - 6

Electromagnetic Flowmeter Model DMH Connection box for sensor, separate version 205 Sensor, flange connection * Weights of the sensors are only approximate values, including the weight of the electronics approx. 2.4 kg 6 No responsibility taken for errors; subject to change wit

Open the catalog to page 6
DMH - 7

Electromagnetic Flowmeter Model DMH Dimensions (continuation) Sensor, wafer flange * eights of the sensors are only approximate values, including the weight of W the electronics approx. 2.4 kg No responsibility taken for errors; subject to change without prior notice.

Open the catalog to page 7

All KOBOLD Messring GmbH catalogs and technical brochures