TMU

TMU
1 / 13 PagesView full catalog

TMU

Product catalog summary
Overview: The document outlines the technical specifications and ordering information for the Kobold Coriolis Mass Flow Meter Model TMU, which measures mass flow, density, and temperature of liquids and gases. It is applicable in industries such as chemical, petrochemical, food, oil, and gas.
Specifications:
  • Measuring Range: 0 - 60 kg/h to 0 - 2200 t/h for water.
  • Accuracy: ±0.1% for liquids and ±0.5% for gases.
  • Pressure and Temperature: Maximum pressure PN 40, temperature range -40 to +260°C.
  • Materials: Stainless steel 1.4404 (316 L), 1.4571 (316 Ti), Hastelloy C-22.
  • Connections: Flange DN 10 to DN 400, ½" to 14" class 150/300.
Transmitter Details:
  • UMC3 and UMC4 Models: Offer integrated or remote mounting options, with power supply options from 19-36 VDC to 90-265 VAC.
  • Outputs: Include galvanically isolated 4-20 mA current outputs, binary outputs, and frequency outputs.
  • Communication Protocols: HART®, Profibus® PA, Fieldbus® Foundation™, Modbus RTU.
Technical Details:
  • Measuring Principle: Coriolis.
  • Protection: IP 66/68 (EN60529).
  • Certificates: Explosion protection and CE-marking for pressure equipment.
Order Details: The document provides a guide for ordering, including model/material selection, sensor/measuring range, process connection, containment, and heating/cooling options. Configurations are available for different applications.
Application Areas: Suitable for precise dosing, loading, and unloading applications, with approvals for fiscal metering.
Additional Information: Includes tables for measuring ranges, accuracy, and calibration options, as well as dimensioning details for the TMU instrument.
Mounting and Power Supply:
  • Various configurations for remote and integrated transmitters with different thread types.
  • Power supply options include 90-265 VAC, 50/60 Hz and 19-36 VDC, 24 VAC (±20%), 50/60 Hz.
Output Types and Approvals:
  • Analogue output (0 (4) - 20 mA) with/without HART®, pulse output, Profibus PA, Profibus DP V1, Modbus RTU, and Fieldbus Foundation.
  • Explosion-proof certifications for different ambient temperature ranges.
Dimensions: Detailed dimensions for different TMU models, including installation lengths and end connections, vary based on transmitter mounting and temperature range.
Additional Notes: Information is subject to change without notice, and special lengths and configurations are available upon request.
See more

Catalog excerpts

TMU-1

Coriolis Mass Flow Meter Measuring range: 0 - 60 kg/h … 0 - 2200 t/h water Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Connection: flange DN 10… DN 400, ½"… 14" class 150/300 Options: contacts, analogue output with HART®, Profibus-PA®, Fieldbus® Foundation™ or Modbus RTU OO KOBOLD companies worldwide: ARGENTINA, AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLoMBIA, CZECHIA, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, Republic of Korea, ROMANIA, SINGAPORE, SPAIN, SWITZERLAND, TAIWAN, THAILAND, TUNISIA, turkey, USA, VIETNAM KOBOLD Messring GmbH Nordring 22-24 D-65719 Hofheim/Ts. Head Office: +49(0)6192 299-0 +49(0)6192 23398 info

 Open the catalog to page 1
TMU-2

Coriolis Mass Flow Meter Model TMU Description The Kobold Mass Flow Meter model TMU utilizes the Coriolis principle of operation to measure mass flow. Density and temperature are simultaneously monitored and volumetric flow is additionally calculated with these parameters. The TMU Series is available with a direct mounted transmitter or in a remote mounted configuration. The unit can be used to meter nearly all liquid or gaseous media and was especially designed to operate in many standard applications. It is applied in many different industrial branches. The TMU Series is also used for precise...

 Open the catalog to page 2
TMU-3

Coriolis Mass Flow Meter Model TMU Technical Details (continued) Pulse output Binary 1: Pulse value: Status: Ambient temperature: Protection: Communication: Accuracy Liquid: pulse duration, standard 50 ms, adjustable from 0,1 ... 2000 ms pulse/pause ratio 1:1 (if the set pulse duration is below limit) as frequency output: max. 1 KHz passive, optocoupler, U„om: 24 V, Ui = 30 V, Ii = 60 mA, Pi = 1,8 W settable in decade increments of selected pulse unit (e. g. kg or m3) forward flow, reverse flow, Min. / Max. flow rate, Min. / Max. density, Min. / Max. temperature, alarm, second pulse output (out...

 Open the catalog to page 3
TMU-4

Coriolis Mass Flow Meter Model TMU Order Details Sensor (Example: TMU-S008 6010 A00 A 0 1 0) Model / material Sensor / measuring range 6010 = ¼" NPT IG 6030 = ½" NPT IG 301B = flange DN10 PN 40 2) 305B = flange DN15 PN 40 2) 309B = flange DN 25 PN 40 2) 201R = flange ½" Class 150 RF 3) 241R = flange ½" Class 600 RF 3) 202R = flange ¾" Class 150 RF 3) 242R = flange ¾" Class 600 RF 3) 223R = flange 1" Class 300 RF 3) 225R = flange 1½" Class 300 RF 3) XXXX = special (please specify in clear text) Heating/ cooling 6010 = ¼" NPT IG 6030 = ½" NPT IG 301B = flange DN10 PN 40 2) 201R = flange ½" Class...

 Open the catalog to page 4
TMU-5

Order Details Sensor (Example: TMU-S008 6010 A00 A 0 1 0) (continued) Model / material Sensor / measuring range Heating/ cooling 317B = flange DN 40 PN 40 2) 321B = flange DN 50 PN 40 2) 331B = flange DN 80 PN 40 2) 205R = flange 1 y" Class 150 RF 245R = flange 1 y2" Class 600 RF 226R = flange 2" Class 300 RF 206R = flange 2" Class 150 RF 3) 228R = flange 3" Class 300 RF 3) 250R = flange 4" Class 600 RF 3) XXXX = special (please specify in clear text) TMU-S.. stainless steel = flange DN 40 PN 40 2) = flange DN 50 PN 40 2) = flange DN 80 PN 40 2) = flange DN100 PN16 2) = flange 1 y2" Class 150...

 Open the catalog to page 5
TMU-6

Model / material Sensor / measuring range Heating/ cooling stainless steel 335B = flange DN100 PN16 2) 345B = flange DN150 PN16 2) 350B = flange DN200 PN16 2) 210R = flange 4" Class 150 RF 3) 230R = flange 4" Class 300 RF 3) 212R = flange 6" Class 150 RF 3) 232R = flange 6" Class 300 RF 3) 213R = flange 8" Class 150 RF 3) 233R = flange 8" Class 300 RF 3) XXXX = special (please specify in clear text) 345B = flange DN150 PN16 2) 350B = flange DN200 PN16 2) 356B = flange DN 250 PN16 2) 212R = flange 6" Class 150 RF 3) 232R = flange 6" Class 300 RF 3) 213R = flange 8" Class 150 RF 3) 233R = flange...

 Open the catalog to page 6
TMU-7

Order Details Sensor (continued) No responsibility taken for errors; subject to change without prior notice. • operating pressure • viscosity • density

 Open the catalog to page 7
TMU-8

Order Details Transmitter UMC3 (continued) No responsibility taken for errors; subject to change without prior notice.

 Open the catalog to page 8
TMU-9

Installation Length Model No responsibility taken for errors; subject to change without prior notice.

 Open the catalog to page 9
TMU-10

Remote mounted transmitter No responsibility taken for errors; subject to change without prior notice.

 Open the catalog to page 10
TMU-11

Coriolis Mass Flow Meter Model TMU Standard version Models TMU-050 - TMU-300 Integrated transmitter UMC3 Remote mounted transmitter No responsibility taken for errors; subject to change without prior notice.

 Open the catalog to page 11
TMU-12

Dimensions with Transmitter UMC4 Model Remote mounted transmitter 12 No responsibility taken for errors; subject to change without prior notice.

 Open the catalog to page 12
TMU-13

Coriolis Mass Flow Meter Model TMU Standard version Models TMU-050 - TMU-300 Integrated transmitter UMC4 Remote mounted transmitter Dimensions with heating jacket/heating coil on request. No responsibility taken for errors; subject to change without prior notice.

 Open the catalog to page 13

All KOBOLD INSTRUMENTATION catalogs and technical brochures

  1. PSD

    7  Pages

  2. RFS

    2  Pages

  3. KES

    7  Pages

  4. MIK

    7  Pages

  5. DWF

    4  Pages

  6. ATA-K

    4  Pages

  7. HND-F

    7  Pages

  8. AFK-G2

    3  Pages

  9. HND-C

    3  Pages

  10. ACM-1

    6  Pages

  11. HND-R

    4  Pages

  12. APM-1

    6  Pages

  13. HND-T120

    10  Pages

  14. MWD

    21  Pages

  15. TNF

    6  Pages

  16. TNS

    6  Pages

  17. TWP

    4  Pages

  18. TDD-1

    3  Pages

  19. TWR

    2  Pages

  20. TSA

    2  Pages

  21. TRS

    2  Pages

  22. M

    23  Pages

  23. NSV

    4  Pages

  24. NIR-9

    5  Pages

  25. MM

    13  Pages

  26. NGM

    10  Pages

  27. NUS-4

    5  Pages

  28. NMF

    4  Pages

  29. NGR

    7  Pages

  30. PLS

    2  Pages

  31. PAS

    22  Pages

  32. NWS

    5  Pages

  33. NVI

    3  Pages

  34. NV

    2  Pages

  35. NTB

    3  Pages

  36. NSC

    4  Pages

  37. NMT

    2  Pages

  38. NMC

    4  Pages

  39. NKP

    2  Pages

  40. NGS

    8  Pages

  41. NES

    2  Pages

  42. NEC

    6  Pages

  43. NCW

    4  Pages

  44. NBK

    5  Pages

  45. LNM

    2  Pages

  46. PUM

    2  Pages

  47. HND-P105

    8  Pages

  48. SEN-96

    3  Pages

  49. MAN-SD

    4  Pages

  50. SEN-86 AUF

    6  Pages

  51. SCH

    21  Pages

  52. PMP

    2  Pages

  53. PAD

    23  Pages

  54. DAK-1

    6  Pages

  55. DAT-1

    6  Pages

  56. DKB

    3  Pages

  57. DKF

    2  Pages

  58. DAA

    2  Pages

  59. DAR

    6  Pages

  60. DON-...LCD

    10  Pages

  61. EPS

    7  Pages

  62. BGN

    6  Pages

  63. MIM

    10  Pages

  64. TSK

    6  Pages

  65. DUC

    13  Pages

  66. VKP

    2  Pages

  67. VKM

    7  Pages

  68. VKG

    7  Pages

  69. URM

    4  Pages

  70. URK

    4  Pages

  71. TME

    8  Pages

  72. SMV

    10  Pages

  73. PSR

    5  Pages

  74. PPS

    2  Pages

  75. PIT

    11  Pages

  76. PEL-L

    4  Pages

  77. KSM

    4  Pages

  78. KDF/KDG

    4  Pages

  79. KAL-D

    3  Pages

  80. DVH / DVE

    8  Pages

  81. DVK

    6  Pages

  82. DUK-C

    7  Pages

  83. KSR/SVN

    2  Pages

  84. DSV-3

    4  Pages

  85. DRH AUF

    6  Pages

  86. DPL-F

    4  Pages

  87. DPE-F

    5  Pages

  88. DOT

    5  Pages

  89. DMS

    4  Pages

  90. Product Summary

    44  Pages

  91. DON

    13  Pages

Archived catalogs

  1. DWU

    5  Pages

  2. DWD

    4  Pages

  3. 2018 KDS

    6  Pages

  4. 2013 KDS

    5  Pages

  5. 2016 BGF

    6  Pages

  6. 2020 BGF

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.