TMU
13Pages

{{requestButtons}}

Catalog excerpts

TMU - 1

Coriolis Mass Flow Meter Measuring range: 0 - 60 kg/h … 0 - 2200 t/h water Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Connection: flange DN 10… DN 400, ½"… 14" class 150/300 Options: contacts, analogue output with HART®, Profibus-PA®, Fieldbus® Foundation™ or Modbus RTU OO KOBOLD companies worldwide: ARGENTINA, AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLoMBIA, CZECHIA, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, Republic of Korea, ROMANIA, SINGAPORE, SPAIN, SWITZERLAND, TAIWAN, THAILAND, TUNISIA, turkey, USA, VIETNAM KOBOLD Messring GmbH Nordring 22-24 D-65719 Hofheim/Ts. Head Office: +49(0)6192 299-0 +49(0)6192 23398 info

Open the catalog to page 1
TMU - 2

Coriolis Mass Flow Meter Model TMU Description The Kobold Mass Flow Meter model TMU utilizes the Coriolis principle of operation to measure mass flow. Density and temperature are simultaneously monitored and volumetric flow is additionally calculated with these parameters. The TMU Series is available with a direct mounted transmitter or in a remote mounted configuration. The unit can be used to meter nearly all liquid or gaseous media and was especially designed to operate in many standard applications. It is applied in many different industrial branches. The TMU Series is also used for...

Open the catalog to page 2
TMU - 3

Coriolis Mass Flow Meter Model TMU Technical Details (continued) Pulse output Binary 1: Pulse value: Status: Ambient temperature: Protection: Communication: Accuracy Liquid: pulse duration, standard 50 ms, adjustable from 0,1 ... 2000 ms pulse/pause ratio 1:1 (if the set pulse duration is below limit) as frequency output: max. 1 KHz passive, optocoupler, U„om: 24 V, Ui = 30 V, Ii = 60 mA, Pi = 1,8 W settable in decade increments of selected pulse unit (e. g. kg or m3) forward flow, reverse flow, Min. / Max. flow rate, Min. / Max. density, Min. / Max. temperature, alarm, second pulse output...

Open the catalog to page 3
TMU - 4

Coriolis Mass Flow Meter Model TMU Order Details Sensor (Example: TMU-S008 6010 A00 A 0 1 0) Model / material Sensor / measuring range 6010 = ¼" NPT IG 6030 = ½" NPT IG 301B = flange DN10 PN 40 2) 305B = flange DN15 PN 40 2) 309B = flange DN 25 PN 40 2) 201R = flange ½" Class 150 RF 3) 241R = flange ½" Class 600 RF 3) 202R = flange ¾" Class 150 RF 3) 242R = flange ¾" Class 600 RF 3) 223R = flange 1" Class 300 RF 3) 225R = flange 1½" Class 300 RF 3) XXXX = special (please specify in clear text) Heating/ cooling 6010 = ¼" NPT IG 6030 = ½" NPT IG 301B = flange DN10 PN 40 2) 201R = flange ½"...

Open the catalog to page 4
TMU - 5

Order Details Sensor (Example: TMU-S008 6010 A00 A 0 1 0) (continued) Model / material Sensor / measuring range Heating/ cooling 317B = flange DN 40 PN 40 2) 321B = flange DN 50 PN 40 2) 331B = flange DN 80 PN 40 2) 205R = flange 1 y" Class 150 RF 245R = flange 1 y2" Class 600 RF 226R = flange 2" Class 300 RF 206R = flange 2" Class 150 RF 3) 228R = flange 3" Class 300 RF 3) 250R = flange 4" Class 600 RF 3) XXXX = special (please specify in clear text) TMU-S.. stainless steel = flange DN 40 PN 40 2) = flange DN 50 PN 40 2) = flange DN 80 PN 40 2) = flange DN100 PN16 2) = flange 1 y2" Class...

Open the catalog to page 5
TMU - 6

Model / material Sensor / measuring range Heating/ cooling stainless steel 335B = flange DN100 PN16 2) 345B = flange DN150 PN16 2) 350B = flange DN200 PN16 2) 210R = flange 4" Class 150 RF 3) 230R = flange 4" Class 300 RF 3) 212R = flange 6" Class 150 RF 3) 232R = flange 6" Class 300 RF 3) 213R = flange 8" Class 150 RF 3) 233R = flange 8" Class 300 RF 3) XXXX = special (please specify in clear text) 345B = flange DN150 PN16 2) 350B = flange DN200 PN16 2) 356B = flange DN 250 PN16 2) 212R = flange 6" Class 150 RF 3) 232R = flange 6" Class 300 RF 3) 213R = flange 8" Class 150 RF 3) 233R =...

Open the catalog to page 6
TMU - 7

Order Details Sensor (continued) No responsibility taken for errors; subject to change without prior notice. • operating pressure • viscosity • density

Open the catalog to page 7
TMU - 8

Order Details Transmitter UMC3 (continued) No responsibility taken for errors; subject to change without prior notice.

Open the catalog to page 8
TMU - 9

Installation Length Model No responsibility taken for errors; subject to change without prior notice.

Open the catalog to page 9
TMU - 10

Remote mounted transmitter No responsibility taken for errors; subject to change without prior notice.

Open the catalog to page 10
TMU - 11

Coriolis Mass Flow Meter Model TMU Standard version Models TMU-050 - TMU-300 Integrated transmitter UMC3 Remote mounted transmitter No responsibility taken for errors; subject to change without prior notice.

Open the catalog to page 11
TMU - 12

Dimensions with Transmitter UMC4 Model Remote mounted transmitter 12 No responsibility taken for errors; subject to change without prior notice.

Open the catalog to page 12
TMU - 13

Coriolis Mass Flow Meter Model TMU Standard version Models TMU-050 - TMU-300 Integrated transmitter UMC4 Remote mounted transmitter Dimensions with heating jacket/heating coil on request. No responsibility taken for errors; subject to change without prior notice.

Open the catalog to page 13

All KOBOLD INSTRUMENTATION catalogs and technical brochures

  1. PSD

    7 Pages

  2. RFS

    2 Pages

  3. KES

    7 Pages

  4. BGN

    6 Pages

  5. MIK

    7 Pages

  6. DWF

    4 Pages

  7. ATA-K

    4 Pages

  8. HND-F

    7 Pages

  9. AFK-G2

    3 Pages

  10. HND-C

    3 Pages

  11. ACM-1

    6 Pages

  12. HND-R

    4 Pages

  13. APM-1

    6 Pages

  14. HND-T120

    10 Pages

  15. MWD

    21 Pages

  16. TNF

    6 Pages

  17. TNS

    6 Pages

  18. TWP

    4 Pages

  19. TDD-1

    3 Pages

  20. TWR

    2 Pages

  21. TSA

    2 Pages

  22. TRS

    2 Pages

  23. M

    23 Pages

  24. NSV

    4 Pages

  25. NIR-9

    5 Pages

  26. MM

    13 Pages

  27. NGM

    10 Pages

  28. NUS-4

    5 Pages

  29. NMF

    4 Pages

  30. NGR

    7 Pages

  31. PLS

    2 Pages

  32. PAS

    22 Pages

  33. NWS

    5 Pages

  34. NVI

    3 Pages

  35. NV

    2 Pages

  36. NTB

    3 Pages

  37. NSC

    4 Pages

  38. NMT

    2 Pages

  39. NMC

    4 Pages

  40. NKP

    2 Pages

  41. NGS

    8 Pages

  42. NES

    2 Pages

  43. NEC

    6 Pages

  44. NCW

    4 Pages

  45. NBK

    5 Pages

  46. LNM

    2 Pages

  47. PUM

    2 Pages

  48. HND-P105

    8 Pages

  49. SEN-96

    3 Pages

  50. MAN-SD

    4 Pages

  51. SEN-86 AUF

    6 Pages

  52. SCH

    21 Pages

  53. PMP

    2 Pages

  54. PAD

    23 Pages

  55. DAK-1

    6 Pages

  56. DAT-1

    6 Pages

  57. DKB

    3 Pages

  58. DKF

    2 Pages

  59. DAA

    2 Pages

  60. DAR

    6 Pages

  61. BGF

    6 Pages

  62. DON-...LCD

    10 Pages

  63. KDS

    6 Pages

  64. EPS

    7 Pages

  65. BGN

    6 Pages

  66. MIK

    7 Pages

  67. MIM

    10 Pages

  68. TSK

    6 Pages

  69. DUC

    13 Pages

  70. VKP

    2 Pages

  71. VKM

    7 Pages

  72. VKG

    7 Pages

  73. URM

    4 Pages

  74. URK

    4 Pages

  75. TME

    8 Pages

  76. SMV

    10 Pages

  77. PSR

    5 Pages

  78. PPS

    2 Pages

  79. PIT

    11 Pages

  80. PEL-L

    4 Pages

  81. KSM

    4 Pages

  82. KDF/KDG

    4 Pages

  83. KAL-D

    3 Pages

  84. DWU

    5 Pages

  85. DWD

    4 Pages

  86. DVH / DVE

    8 Pages

  87. DVZ-E

    9 Pages

  88. DVK

    6 Pages

  89. DUK-C

    7 Pages

  90. KSR/SVN

    2 Pages

  91. DSV-3

    4 Pages

  92. DRH AUF

    6 Pages

  93. DPL-F

    4 Pages

  94. DPE-F

    5 Pages

  95. DOT

    5 Pages

  96. DMS

    4 Pages

  97. KDS

    5 Pages

  98. BGF

    6 Pages

  99. DON

    9 Pages