Catalog excerpts
Coriolis Mass Flow Meter Measuring range: 0 - 60 kg/h … 0 - 2200 t/h water Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Connection: flange DN 10… DN 400, ½"… 14" class 150/300 Options: contacts, analogue output with HART®, Profibus-PA®, Fieldbus® Foundation™ or Modbus RTU OO KOBOLD companies worldwide: ARGENTINA, AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLoMBIA, CZECHIA, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, Republic of Korea, ROMANIA, SINGAPORE, SPAIN, SWITZERLAND, TAIWAN, THAILAND, TUNISIA, turkey, USA, VIETNAM KOBOLD Messring GmbH Nordring 22-24 D-65719 Hofheim/Ts. Head Office: +49(0)6192 299-0 +49(0)6192 23398 info
Open the catalog to page 1Coriolis Mass Flow Meter Model TMU Description The Kobold Mass Flow Meter model TMU utilizes the Coriolis principle of operation to measure mass flow. Density and temperature are simultaneously monitored and volumetric flow is additionally calculated with these parameters. The TMU Series is available with a direct mounted transmitter or in a remote mounted configuration. The unit can be used to meter nearly all liquid or gaseous media and was especially designed to operate in many standard applications. It is applied in many different industrial branches. The TMU Series is also used for...
Open the catalog to page 2Coriolis Mass Flow Meter Model TMU Technical Details (continued) Pulse output Binary 1: Pulse value: Status: Ambient temperature: Protection: Communication: Accuracy Liquid: pulse duration, standard 50 ms, adjustable from 0,1 ... 2000 ms pulse/pause ratio 1:1 (if the set pulse duration is below limit) as frequency output: max. 1 KHz passive, optocoupler, U„om: 24 V, Ui = 30 V, Ii = 60 mA, Pi = 1,8 W settable in decade increments of selected pulse unit (e. g. kg or m3) forward flow, reverse flow, Min. / Max. flow rate, Min. / Max. density, Min. / Max. temperature, alarm, second pulse output...
Open the catalog to page 3Coriolis Mass Flow Meter Model TMU Order Details Sensor (Example: TMU-S008 6010 A00 A 0 1 0) Model / material Sensor / measuring range 6010 = ¼" NPT IG 6030 = ½" NPT IG 301B = flange DN10 PN 40 2) 305B = flange DN15 PN 40 2) 309B = flange DN 25 PN 40 2) 201R = flange ½" Class 150 RF 3) 241R = flange ½" Class 600 RF 3) 202R = flange ¾" Class 150 RF 3) 242R = flange ¾" Class 600 RF 3) 223R = flange 1" Class 300 RF 3) 225R = flange 1½" Class 300 RF 3) XXXX = special (please specify in clear text) Heating/ cooling 6010 = ¼" NPT IG 6030 = ½" NPT IG 301B = flange DN10 PN 40 2) 201R = flange ½"...
Open the catalog to page 4Order Details Sensor (Example: TMU-S008 6010 A00 A 0 1 0) (continued) Model / material Sensor / measuring range Heating/ cooling 317B = flange DN 40 PN 40 2) 321B = flange DN 50 PN 40 2) 331B = flange DN 80 PN 40 2) 205R = flange 1 y" Class 150 RF 245R = flange 1 y2" Class 600 RF 226R = flange 2" Class 300 RF 206R = flange 2" Class 150 RF 3) 228R = flange 3" Class 300 RF 3) 250R = flange 4" Class 600 RF 3) XXXX = special (please specify in clear text) TMU-S.. stainless steel = flange DN 40 PN 40 2) = flange DN 50 PN 40 2) = flange DN 80 PN 40 2) = flange DN100 PN16 2) = flange 1 y2" Class...
Open the catalog to page 5Model / material Sensor / measuring range Heating/ cooling stainless steel 335B = flange DN100 PN16 2) 345B = flange DN150 PN16 2) 350B = flange DN200 PN16 2) 210R = flange 4" Class 150 RF 3) 230R = flange 4" Class 300 RF 3) 212R = flange 6" Class 150 RF 3) 232R = flange 6" Class 300 RF 3) 213R = flange 8" Class 150 RF 3) 233R = flange 8" Class 300 RF 3) XXXX = special (please specify in clear text) 345B = flange DN150 PN16 2) 350B = flange DN200 PN16 2) 356B = flange DN 250 PN16 2) 212R = flange 6" Class 150 RF 3) 232R = flange 6" Class 300 RF 3) 213R = flange 8" Class 150 RF 3) 233R =...
Open the catalog to page 6Order Details Sensor (continued) No responsibility taken for errors; subject to change without prior notice. • operating pressure • viscosity • density
Open the catalog to page 7Order Details Transmitter UMC3 (continued) No responsibility taken for errors; subject to change without prior notice.
Open the catalog to page 8Installation Length Model No responsibility taken for errors; subject to change without prior notice.
Open the catalog to page 9Remote mounted transmitter No responsibility taken for errors; subject to change without prior notice.
Open the catalog to page 10Coriolis Mass Flow Meter Model TMU Standard version Models TMU-050 - TMU-300 Integrated transmitter UMC3 Remote mounted transmitter No responsibility taken for errors; subject to change without prior notice.
Open the catalog to page 11Dimensions with Transmitter UMC4 Model Remote mounted transmitter 12 No responsibility taken for errors; subject to change without prior notice.
Open the catalog to page 12Coriolis Mass Flow Meter Model TMU Standard version Models TMU-050 - TMU-300 Integrated transmitter UMC4 Remote mounted transmitter Dimensions with heating jacket/heating coil on request. No responsibility taken for errors; subject to change without prior notice.
Open the catalog to page 13All KOBOLD INSTRUMENTATION catalogs and technical brochures
-
PSD
7 Pages
-
RFS
2 Pages
-
KES
7 Pages
-
BGN
6 Pages
-
MIK
7 Pages
-
DWF
4 Pages
-
ATA-K
4 Pages
-
HND-F
7 Pages
-
AFK-G2
3 Pages
-
HND-C
3 Pages
-
ACM-1
6 Pages
-
HND-R
4 Pages
-
APM-1
6 Pages
-
HND-T120
10 Pages
-
MWD
21 Pages
-
TNF
6 Pages
-
TNS
6 Pages
-
TWP
4 Pages
-
TDD-1
3 Pages
-
TWR
2 Pages
-
TSA
2 Pages
-
TRS
2 Pages
-
M
23 Pages
-
NSV
4 Pages
-
NIR-9
5 Pages
-
MM
13 Pages
-
NGM
10 Pages
-
NUS-4
5 Pages
-
NMF
4 Pages
-
NGR
7 Pages
-
PLS
2 Pages
-
PAS
22 Pages
-
NWS
5 Pages
-
NVI
3 Pages
-
NV
2 Pages
-
NTB
3 Pages
-
NSC
4 Pages
-
NMT
2 Pages
-
NMC
4 Pages
-
NKP
2 Pages
-
NGS
8 Pages
-
NES
2 Pages
-
NEC
6 Pages
-
NCW
4 Pages
-
NBK
5 Pages
-
LNM
2 Pages
-
PUM
2 Pages
-
HND-P105
8 Pages
-
SEN-96
3 Pages
-
MAN-RF...M21..DRM-602
4 Pages
-
MAN-SD
4 Pages
-
SEN-86 AUF
6 Pages
-
SEN-3251 / 3252
3 Pages
-
SCH
21 Pages
-
PMP
2 Pages
-
PAD
23 Pages
-
DAK-1
6 Pages
-
DAT-1
6 Pages
-
DKB
3 Pages
-
DKF
2 Pages
-
DAA
2 Pages
-
DAR
6 Pages
-
BGF
6 Pages
-
DON-...LCD
10 Pages
-
KDS
6 Pages
-
EPS
7 Pages
-
BGN
6 Pages
-
MIK
7 Pages
-
MIM
10 Pages
-
TSK
6 Pages
-
DUC
13 Pages
-
VKP
2 Pages
-
VKM
7 Pages
-
VKG
7 Pages
-
URM
4 Pages
-
URK
4 Pages
-
TME
8 Pages
-
SMV
10 Pages
-
PSR
5 Pages
-
PPS
2 Pages
-
PIT
11 Pages
-
PEL-L
4 Pages
-
KSM
4 Pages
-
KDF/KDG
4 Pages
-
KAL-D
3 Pages
-
DWU
5 Pages
-
DWD
4 Pages
-
DVH / DVE
8 Pages
-
DVZ-E
9 Pages
-
DVK
6 Pages
-
DUK-C
7 Pages
-
KSR/SVN
2 Pages
-
DSV-3
4 Pages
-
DRH AUF
6 Pages
-
DPL-F
4 Pages
-
DPE-F
5 Pages
-
DOT
5 Pages
-
DMS
4 Pages
-
Program summary 2018
48 Pages
-
KDS
5 Pages
-
BGF
6 Pages
-
DON
9 Pages