SCH
21Pages

{{requestButtons}}

Catalog excerpts

SCH - 1

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure Switching range: -1 ... + 0.1 bar - 250 ... +100 mbar, 1 ... 16 mbar a 16 ... 63 bar Temperature: max. 70 °C Material: copper, brass, stainless steel, NBR KOBOLD companies worldwide: AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHINA, CZECHIA, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, Republic of Korea, ROMANIA, RUSSIA, SPAIN, SWITZERLAND, THAILAND, TUNISIA, turkey, USA, VIETNAM KOBOLD Messring GmbH Nordring 22-24 D-65719 Hofheim/Ts. Head Office: +49(0)6192 299-0 +49(0)6192 23398

Open the catalog to page 1
SCH - 2

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure Model SCH General Description Mode of operation The pressure applied in the sensor housing (1) acts on the measuring bellows (2). Pressure changes lead to movements of the measuring bellows (2) which are transferred through a pressure pin (4) to the switching rocker (5). The switching rocker is supported on hardened pivot points (6). As the pressure increases the switching rocker (5) moves upwards and operates the micro-switch (7). The spring (8), the initial stress of which can be changed by the...

Open the catalog to page 2
SCH - 3

Mechanical Pressure Switches The most important technical data Model SCH Technical Details Valid for all pressure switches with microswitches of the DCM, VCM, DNM, DNS, DDC series. The technical data of the component tested units deviate partly slightly. (Please refer to model sheet) Normal version -version Plug connection Terminal connection Switch housing Pressure connection Aluminium die-cast GD Al Si 12 Aluminium die-cast GD Al Si 12 G ½ external thread (pressure gauge connection) and G ¼ internal thread. Internal thread G ¼ at differential pressure switches DDCM. (only for version with...

Open the catalog to page 3
SCH - 4

Pressure Switches Switch units / optional function / connection diagrams Model SCH Connection diagram Normal version microswitch, single pole switching over, switching differential not adjustable Maximum limiter with manual reset device. Interlocking with increasing pressure Minimum limiter with manual reset device. Interlocking with falling pressure Gilded contacts hysteresis not adjustable Switching capacity max. 24 VDC, 100 mA min. 5 VDC, 2 mA DCM025…DCM63, DNM, VCM301…VCM095, VNM, (DDCM), VNS, DNS Terminal connection instead of plug connection protection IP 65 Two microswitches...

Open the catalog to page 4
SCH - 5

Switch diagram Option 217 Pressure switches with special equipment can also be used in the Ex area Zone 1. The following alternatives are possible: Pressure switch with pressure-proof encapsulated switching device, degree of protection <g> II 2G Ex d e IIC T6 Gb and <g> II 1/2D Ex ta/tb MIC T80°C Da/ Db -20°C <Ta <+60°C. The pressure switch in pressure-proof encapsulation can be used directly in the Ex area (> Zone 1). Maximum switching voltage, switching capacity and ambient temperature must be taken into account and the rules for the installation in the Ex area must be observed. All...

Open the catalog to page 5
SCH - 6

Component Tests Model SCH ATEX approvals II 2G Ex d e IIC T6 Gb II 1/2D Ex ta/tb IIIC T80 °C Da/Db -20 °C ≤ Ta ≤ +60 °C Model SCH-Ex... Switch housing with switching mechanisms The switch housings consist of high quality and seawater-resistant aluminium diecastings. Three versions are available: IP 54 Housing (normal version) Plug connections to EN 175301; Degree of protection IP 54; Setpoint setting accessible from the outside. Terminal connection (option: 301) With terminal connection box; Degree of protection IP 65; Setpoint setting and terminal connections accessible only after removal...

Open the catalog to page 6
SCH - 7

Pressure Limiters with Switching Status Lock (restart lockout) Model SCH — 1 In limiter functions it is frequently necessary to retain and lock the shutdown status and to release the lock and switch on the system again only after the causes that led to the safety shutdown have been eliminated. There are two possibilities for this: 1. Mechanical lock inside the pressure switch A "bistable" microswitch is built into the limiters instead of the microswitch with automatic reset. When the value set on the scale is reached, the microswitch switches over and remains in this position. The lock must...

Open the catalog to page 7
SCH - 8

Pressure Switches and Pressure Monitors for overpressure for non aggressive liquid and gaseous media Model SCH-DCM Technical Details Pressure connection: Switching device: Protection: Pressure sensing element: Fitting position: Max. ambient temperature at the switch unit: external thread G % A (pressure gauge connection) acc. to DIN 16 288 and internal thread G 14 to ISO 228 part 1 rugged housing of seawater resistant aluminium die-casting GD Al Si 12 IP 54, with vertical fitting position DCM 3 ... DCM 63 metal bellows: 1.4571 sensor casing: 1.4104 DCM 025-DCM 1 diaphragm: Cu sensor casing:...

Open the catalog to page 8
SCH - 9

Mechanical Pressure Switches • Summary of Models SCH-DCM, SCH-DCMV Model Order specification Pressure switch with plug connection, housing of aluminium die-casting adjustment range from ... to ... bar / mbar Switching differential adjustable / none adjustable Model. No responsibility taken for errors; subject to change without prior notice.

Open the catalog to page 9
SCH - 10

Pressure Switches with Sensor System in Stainless Steel Version Model SCH-DNM Technical Details Pressure connection: Switching device: Protection: Pressure sensing element: Fitting position: Max. ambient temperature at the switch unit: Max. temperature of the medium: external thread G % A (pressure All parts of the SCH-DNM series of pressure switches which gauge connection) acc. to DIN 16 288 come into contact with the medium are made of stainless and internal thread G 14 to ISO 228 steel. The pressure sensor is welded by the most up-to-date part 1 method without added material. rugged...

Open the catalog to page 10

All KOBOLD INSTRUMENTATION catalogs and technical brochures

  1. PSD

    7 Pages

  2. RFS

    2 Pages

  3. KES

    7 Pages

  4. BGN

    6 Pages

  5. MIK

    7 Pages

  6. DWF

    4 Pages

  7. ATA-K

    4 Pages

  8. HND-F

    7 Pages

  9. AFK-G2

    3 Pages

  10. HND-C

    3 Pages

  11. ACM-1

    6 Pages

  12. HND-R

    4 Pages

  13. APM-1

    6 Pages

  14. HND-T120

    10 Pages

  15. MWD

    21 Pages

  16. TNF

    6 Pages

  17. TNS

    6 Pages

  18. TWP

    4 Pages

  19. TDD-1

    3 Pages

  20. TWR

    2 Pages

  21. TSA

    2 Pages

  22. TRS

    2 Pages

  23. M

    23 Pages

  24. NSV

    4 Pages

  25. NIR-9

    5 Pages

  26. MM

    13 Pages

  27. NGM

    10 Pages

  28. NUS-4

    5 Pages

  29. NMF

    4 Pages

  30. NGR

    7 Pages

  31. PLS

    2 Pages

  32. PAS

    22 Pages

  33. NWS

    5 Pages

  34. NVI

    3 Pages

  35. NV

    2 Pages

  36. NTB

    3 Pages

  37. NSC

    4 Pages

  38. NMT

    2 Pages

  39. NMC

    4 Pages

  40. NKP

    2 Pages

  41. NGS

    8 Pages

  42. NES

    2 Pages

  43. NEC

    6 Pages

  44. NCW

    4 Pages

  45. NBK

    5 Pages

  46. LNM

    2 Pages

  47. PUM

    2 Pages

  48. HND-P105

    8 Pages

  49. SEN-96

    3 Pages

  50. MAN-SD

    4 Pages

  51. SEN-86 AUF

    6 Pages

  52. PMP

    2 Pages

  53. PAD

    23 Pages

  54. DAK-1

    6 Pages

  55. DAT-1

    6 Pages

  56. DKB

    3 Pages

  57. DKF

    2 Pages

  58. DAA

    2 Pages

  59. DAR

    6 Pages

  60. BGF

    6 Pages

  61. DON-...LCD

    10 Pages

  62. KDS

    6 Pages

  63. EPS

    7 Pages

  64. BGN

    6 Pages

  65. MIK

    7 Pages

  66. MIM

    10 Pages

  67. TSK

    6 Pages

  68. DUC

    13 Pages

  69. VKP

    2 Pages

  70. VKM

    7 Pages

  71. VKG

    7 Pages

  72. URM

    4 Pages

  73. URK

    4 Pages

  74. TMU

    13 Pages

  75. TME

    8 Pages

  76. SMV

    10 Pages

  77. PSR

    5 Pages

  78. PPS

    2 Pages

  79. PIT

    11 Pages

  80. PEL-L

    4 Pages

  81. KSM

    4 Pages

  82. KDF/KDG

    4 Pages

  83. KAL-D

    3 Pages

  84. DWU

    5 Pages

  85. DWD

    4 Pages

  86. DVH / DVE

    8 Pages

  87. DVZ-E

    9 Pages

  88. DVK

    6 Pages

  89. DUK-C

    7 Pages

  90. KSR/SVN

    2 Pages

  91. DSV-3

    4 Pages

  92. DRH AUF

    6 Pages

  93. DPL-F

    4 Pages

  94. DPE-F

    5 Pages

  95. DOT

    5 Pages

  96. DMS

    4 Pages

  97. KDS

    5 Pages

  98. BGF

    6 Pages

  99. DON

    9 Pages