Magnetic Inductive Flowmeter Accuracy: ±1.5% of reading ± 0.5% of full scale Connection: flange DN 40 ... 80, ANSI 2" ... 3" Material: stainless steel / PTFE or PFA Outputs: analogue with HART®, pulse and status OO KOBOLD companies worldwide: AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHINA, CZECHIA, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, Republic of Korea, ROMANIA, SPAIN, SWITZERLAND, THAILAND, TUNISIA, turkey, USA, VIETNAM KOBOLD Messring GmbH Nordring 22-24 D-65719 Hofheim/Ts. Head Office: +49(0)6192 299-0 +49(0)6192 23398 info.
Open the catalog to page 1Magnetic Inductive Flowmeter Model PIT Description An electrically conductive medium induces a voltage while flowing through an arranged magnetic field in accordance to the Faraday's induction law. The electrode currency is proportional to the flow velocity and therewith to the volume flow. The PIT-sensor is available with integral or remote mount transmitter. A retracting device for mounting and dismounting under process conditions is available. The magnetic-inductive PIT flow velocity sensor is used to measure or monitor the volume flow of liquids, slurries, pastes and other electrically conductive...
Open the catalog to page 2Magnetic Inductive Flowmeter Model PIT Technical Details (continued) Code »C« standard: i ntrinsically-safe 1 x current output: 4-20 mA (passive) HART® 1 x pulse output: 1 kHz, passive 24 VDC (Um = 30 VDC) 1 x status output: passive 24 VDC (Um = 30 VDC) Communication: HART® ± 0.5 % adjusted full scale (under reference conditions) Repeatability: ± 0.75 % of reading ± 0.25 % adjusted full scale (under reference conditions) Protection Class Markings Transmitter mounted as compact version Ex d e ib [ia IIC Ga] IIB T4 / T3 Gb Ex tb ib [ia Da] IIIC T125 °C / T150 °C Db Ex d e ib IIB T4 / T3 Gb Ex tb...
Open the catalog to page 3Magnetic Inductive Flowmeter Model PIT Si Order Details Sensor (continued) No responsibility taken for errors; subject to change without prior notice.
Open the catalog to page 4Order Details Sensor for UMF3 (Example: PIT-S 317B 163 H 0 1 E 0 0K) Model/ material/version Process connection Sensor length Electrodes material Measuring range / medium velocity Sensor configuration PIT-S1 = stainless steel (1.4571/1.4404) / PTFE for nominal diameters DN125 - DN2000 (PN16) (PIT-520) PIT-A = PFA for nominal diameters DN125 - DN600 (PN40) (PIT-571) with grounding electrode PIT-U1 = stainless steel for nominal diameters DN125 - DN2000 (PN16) model including installation / extraction device, mounting adaptor and valve 317B = DN 40 PN 40 form B1 DIN EN 1092-1 standard 321B = DN...
Open the catalog to page 5Magnetic Inductive Flowmeter Model PIT Si Order Details Transmitter UMF3 (Example: UMF3- 1 A 3 A 1 1K 1) Interconnecting cable 0 = none (compact version) 1 = 2,5 m standard (on remote version) 2 = 5 m remote version 3 = 10 m remote version 4 = 15 m remote version 5 = 20 m remote version 6 = 30 m remote version 7 = 40 m remote version 8 = 50 m remote version 11 Protection signal output: intrinsically-safe 2) Protection signal output: not intrinsically-safe 3) Certification marking: output C; Ex d e ib [ia IIC Ga] IIB T4-T3 Gb; Ex tb ib [ia Da] IIIC T125°C / T150 °C Db 4) Certification marking:...
Open the catalog to page 6Magnetic Inductive Flowmeter Model PIT Order Details Welding Socket For mounting the installation-, extracting device following things are necessary: Sensor in special version PIT-U326B, welding socket 60019917, valve lock PIT-EWS and pressure screw set PIT-EVD... No responsibility taken for errors; subject to change without prior notice.
Open the catalog to page 7Magnetic Inductive Flowmeter Model PIT Dimensions [mm] UMF2-transmitter compact version Sensor remote version 205 Immersion depth ET = 15% of pipe inside diameter UMF2-remote transmitter with connecting box PIT-S (SS / PTFE) PIT-S (SS / PTFE) PIT-S (SS / PTFE) No responsibility taken for errors; subject to change without prior notice.
Open the catalog to page 8Magnetic Inductive Flowmeter Model PIT Dimensions [mm] (continued) UMF3 transmitter with terminal box and wall bracket for separate montage (Dimensions also apply for the UMF3 transmitter with pigtail cable) No responsibility taken for errors; subject to change without prior notice.
Open the catalog to page 9Magnetic Inductive Flowmeter Model PIT Dimensions [mm] (continued) PIT-S with terminal box for separate montage IP 67 terminal connection box: 57 x 75 x 80 mm Weight: 3.6 kg L: length of socket weld fitting ET: i mmersion depth in % of pipe No responsibility taken for errors; subject to change without prior notice.
Open the catalog to page 105.5 kg nominal diameter length of sensor diameter of sensor length of socket weld fitting No responsibility taken for errors; subject to change without prior notice.
Open the catalog to page 117 Pages
2 Pages
7 Pages
7 Pages
4 Pages
4 Pages
7 Pages
3 Pages
3 Pages
6 Pages
4 Pages
6 Pages
10 Pages
21 Pages
6 Pages
6 Pages
4 Pages
3 Pages
2 Pages
2 Pages
2 Pages
23 Pages
4 Pages
5 Pages
13 Pages
10 Pages
5 Pages
4 Pages
7 Pages
2 Pages
22 Pages
5 Pages
3 Pages
2 Pages
3 Pages
4 Pages
2 Pages
4 Pages
2 Pages
8 Pages
2 Pages
6 Pages
4 Pages
5 Pages
2 Pages
2 Pages
8 Pages
3 Pages
4 Pages
4 Pages
6 Pages
3 Pages
21 Pages
2 Pages
23 Pages
6 Pages
6 Pages
3 Pages
2 Pages
2 Pages
6 Pages
10 Pages
7 Pages
6 Pages
10 Pages
6 Pages
13 Pages
2 Pages
7 Pages
7 Pages
4 Pages
4 Pages
13 Pages
8 Pages
10 Pages
5 Pages
2 Pages
4 Pages
4 Pages
4 Pages
3 Pages
5 Pages
4 Pages
8 Pages
9 Pages
6 Pages
7 Pages
2 Pages
4 Pages
6 Pages
4 Pages
5 Pages
5 Pages
4 Pages
48 Pages
9 Pages