Group: Kobold
Catalog excerpts
Ultrasonic Level Meterfor liquids and solids if! • Measuring range: liquids: up to 25 m solids: up to 10 m • Accuracy: ±0.2 % of reading +0.05 % of full scale • pmax: 3 bar abs. U: 90 °C OO Connection: G 1/2, G 2, iy2" NPT, 2" NPT DIN-flange DN 80, DN 125, DN 150 ANSI-flange 3", 5", 6" • Housing material: aluminium sensor material: PP, PVDF • Output: 4 ... 20 mA, HART®, relay or programming unit with LCD display KOBOLD companies worldwide: ARGENTINA, AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLOMBIA, CZECHIA, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, REPUBLIC OF KOREA, ROMANIA, SINGAPORE, SPAIN, SWITZERLAND, TAIWAN, THAILAND, TUNISIA, TURKEY, USA, VIETNAM KOBOLD Messring GmbH Nordring 22-24 D-65719 Hofheim/Ts. V* Head Office: +49(0)6192 299-0 +49(0)6192 23398 info.de@kobold.com www.kobold.com
Open the catalog to page 1Ultrasonic Level Meter Model NUS-4 Measuring principle: Frequency: Beam cone: Delay time: Meas. accuracy (at 20 °C): Resolution: Mounting position: Process temperature: Ambient temperature: Description The Kobold ultrasonic level meter, model NUS-4, is used for non-contact, continuous level and volume measurement in vessels or for flow measurement in open channels. Level measurement technology based on the non-contacting ultrasonic principle is especially suited for applications where, for any reason, no physical contact can be established to the surface of the material to be measured. Such...
Open the catalog to page 2Ultrasonic Level Meter Model NUS-4 Analogue Output The standard version is delivered with 4 - 20 mA signal output. Output: 4-20 mA max. 600 Q, HART® (optional) The following can be programmed with keys: • Assignment of the 4 or 20 mA signals to the required levels • Error indication by the current output (3.8 mA, 22 mA or hold the last value) • Damping of analogue output (10, 30, 60 s) Factory default: • 4 mA: assigned to the maximum level 0 % • 20 mA: assigned to the minimum level 100 % OO Error indication by the current output: hold last value OO Damping: 60 s. Relay Output: The units may...
Open the catalog to page 3Ultrasonic Level Meter Model NUS-4 Order Details (Example: NUS-4x04 R8 340) Model Sensor material Measuring range 04 = 0.2 - 4 m liquids 0.2 - 1.6 m solids 06 = 0.25 - 6 m liquids 0.25 - 2.4 m solids 08 = 0.35 - 8 m liquids 0.35 - 3.2 m solids 0 = polypropylene 10 = 0.35 - 10 m liquids 9 = PVDF 0.35 - 4 m solids Power supply Output/ display 40 = 4 - 20 mA R0 = 4 - 20 mA and relay 4H = -20 mA + 4 HART® RH -20 mA + =4 HART® + relay 4P = pluggable pro- gramming unit with LCD-display, 4 - 20 mA RP = pluggable pro- gramming unit with LCD-display, 4 - 20 mA, relay pluggable programming unit with...
Open the catalog to page 4Ultrasonic Level Meter Model NUS-4 No responsibility taken for errors; subject to change without prior notice.
Open the catalog to page 5All KOBOLD INSTRUMENTATION catalogs and technical brochures
-
PSD
7 Pages
-
RFS
2 Pages
-
KES
7 Pages
-
BGN
6 Pages
-
MIK
7 Pages
-
DWF
4 Pages
-
ATA-K
4 Pages
-
HND-F
7 Pages
-
AFK-G2
3 Pages
-
HND-C
3 Pages
-
ACM-1
6 Pages
-
HND-R
4 Pages
-
APM-1
6 Pages
-
HND-T120
10 Pages
-
MWD
21 Pages
-
TNF
6 Pages
-
TNS
6 Pages
-
TWP
4 Pages
-
TDD-1
3 Pages
-
TWR
2 Pages
-
TSA
2 Pages
-
TRS
2 Pages
-
M
23 Pages
-
NSV
4 Pages
-
NIR-9
5 Pages
-
MM
13 Pages
-
NGM
10 Pages
-
NMF
4 Pages
-
NGR
7 Pages
-
PLS
2 Pages
-
PAS
22 Pages
-
NWS
5 Pages
-
NVI
3 Pages
-
NV
2 Pages
-
NTB
3 Pages
-
NSC
4 Pages
-
NMT
2 Pages
-
NMC
4 Pages
-
NKP
2 Pages
-
NGS
8 Pages
-
NES
2 Pages
-
NEC
6 Pages
-
NCW
4 Pages
-
NBK
5 Pages
-
LNM
2 Pages
-
PUM
2 Pages
-
HND-P105
8 Pages
-
SEN-96
3 Pages
-
MAN-RF...M21..DRM-602
4 Pages
-
MAN-SD
4 Pages
-
SEN-86 AUF
6 Pages
-
SEN-3251 / 3252
3 Pages
-
SCH
21 Pages
-
PMP
2 Pages
-
PAD
23 Pages
-
DAK-1
6 Pages
-
DAT-1
6 Pages
-
DKB
3 Pages
-
DKF
2 Pages
-
DAA
2 Pages
-
DAR
6 Pages
-
BGF
6 Pages
-
DON-...LCD
10 Pages
-
KDS
6 Pages
-
EPS
7 Pages
-
BGN
6 Pages
-
MIK
7 Pages
-
MIM
10 Pages
-
TSK
6 Pages
-
DUC
13 Pages
-
VKP
2 Pages
-
VKM
7 Pages
-
VKG
7 Pages
-
URM
4 Pages
-
URK
4 Pages
-
TMU
13 Pages
-
TME
8 Pages
-
SMV
10 Pages
-
PSR
5 Pages
-
PPS
2 Pages
-
PIT
11 Pages
-
PEL-L
4 Pages
-
KSM
4 Pages
-
KDF/KDG
4 Pages
-
KAL-D
3 Pages
-
DWU
5 Pages
-
DWD
4 Pages
-
DVH / DVE
8 Pages
-
DVZ-E
9 Pages
-
DVK
6 Pages
-
DUK-C
7 Pages
-
KSR/SVN
2 Pages
-
DSV-3
4 Pages
-
DRH AUF
6 Pages
-
DPL-F
4 Pages
-
DPE-F
5 Pages
-
DOT
5 Pages
-
DMS
4 Pages
-
Program summary 2018
48 Pages
-
KDS
5 Pages
-
BGF
6 Pages
-
DON
9 Pages