Catalog excerpts
Guided Wave Radar Level Transmitter (TDR) monitoring • analysing Independent of density, temperature, pressure, humidity and conductivity P robe length: max. 2000 mm for monoprobe and coaxialtube max. 4000mm for wire rope Output: 4 - 20 mA / 0 - 10 V switching output PNP or NPN KOBOLD companies worldwide: AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHINA, CZECHIA, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, Republic of Korea, ROMANIA, RUSSIA, SPAIN, SWITZERLAND, THAILAND, TUNISIA, turkey, USA, VIETNAM KOBOLD Messring GmbH Nordring 22-24 D-65719 Hofheim/Ts. Head Office: +49(0)6192 299-0 +49(0)6192 23398 info
Open the catalog to page 1Technical Details RoHS certificate: Accuracy of sensor element1): Repeatability: Resolution: Response time: Dielectric constant: Conductivity: Max. level change: Inactive area at probe end1): The NGR is a level sensor that uses TDR technology (time domain reflectometry) and thus can be used in oil- and water-based liquids without calibration. The NGR's guided radar uses time-offlight technology to measure electromagnetic pulses. The time difference between the sent pulse and the reflected pulse is used to calculate the level, both as a continuous value (analogue output) and a freely...
Open the catalog to page 2Guided Wave Radar Level Transmitter (TDR) Model NGR Hysteresis: Inductive load: Capacitive load: Enclosure rating: Temperature drift: Lower signal level: Upper signal level: EMC: Ambient operating temperature: Ambient storage temperature: Technical Details (continuation) Output signal3): analogue output 4 mA ... 20 mA / 0 V . 10 V automatic switching to a current or voltage output depending on the load. 1 PNP-transistor output and 1 PNP/NPN-transistor output switchable (Option 2) or 1 PNP-transistor output and 3 PNP/NPN-transistor output switchable (Option 4) Output load: 4 mA ..20 mA < 500...
Open the catalog to page 3Guided Wave Radar Level Transmitter (TDR) Model NGR Accuracy Diagrams [mm] Accuracy diagram with parameterized tank Accuracy diagram without parameterized tank Accuracy in mm Level in mm Accuracy in mm Level in mm Inactive area Reference conditions: Container with a diameter of 1 m Central installation of the sensor Minimum distance to built-in components > 300 mm Distance from the end of probe to tank bottom > 15 mm Air humidity: 65% +/- 20% Temperature: +20 °C +/- 5 °C Pressure: 1013 mbar abs. +/- 20 mbar. Container parameterization undertaken Medium: water, DK = 80 1 L+: supply voltage,...
Open the catalog to page 4Guided Wave Radar Level Transmitter (TDR) Model NGR with coax tube Wire probe with Coax tube M: measuring range L: probe length IA: inactive area at process connection 25 mm IAE: Inactive area at probe end 10 mm No responsibility taken for errors; subject to change without prior notice.
Open the catalog to page 5Guided Wave Radar Level Transmitter (TDR) Model NGR Installation in a tank Unit with mono probe mounted in metal tank Installation in nozzle: D >= DN 25 Distance tank wall/tank bottom: A >= 50 mm B >= 10 mm Distance to other tank fittings: >= 100 mm with coaxial tube mono probe Unit with coaxial tube for metal and non metal tank C = with a coaxial tube there are no minimum distances to the tank wall or to other tank fittings required Installation of a mono probe in a metal immersion tube or metal bypass D >= DN 40 Distance tank wall/tank bottom: B >= 10 mm bypass pipe. To do this, it is...
Open the catalog to page 6Guided Wave Radar Level Transmitter (TDR) Model NGR Rope probe in the metallic container Roper weight Bracket rope tension Installation in nozzle: D >= DN 25 Container wall / container bottom distance: A >= 50 mm Distance from components built into container: >= 100 mm Mounting the mono-probe M = Measuring range X = No measurement is possible in this area Container welding seams may affect the measurement accuracy. No responsibility taken for errors; subject to change without prior notice.
Open the catalog to page 7All KOBOLD INSTRUMENTATION catalogs and technical brochures
-
PSD
7 Pages
-
RFS
2 Pages
-
KES
7 Pages
-
BGN
6 Pages
-
MIK
7 Pages
-
DWF
4 Pages
-
ATA-K
4 Pages
-
HND-F
7 Pages
-
AFK-G2
3 Pages
-
HND-C
3 Pages
-
ACM-1
6 Pages
-
HND-R
4 Pages
-
APM-1
6 Pages
-
HND-T120
10 Pages
-
MWD
21 Pages
-
TNF
6 Pages
-
TNS
6 Pages
-
TWP
4 Pages
-
TDD-1
3 Pages
-
TWR
2 Pages
-
TSA
2 Pages
-
TRS
2 Pages
-
M
23 Pages
-
NSV
4 Pages
-
NIR-9
5 Pages
-
MM
13 Pages
-
NGM
10 Pages
-
NUS-4
5 Pages
-
NMF
4 Pages
-
PLS
2 Pages
-
PAS
22 Pages
-
NWS
5 Pages
-
NVI
3 Pages
-
NV
2 Pages
-
NTB
3 Pages
-
NSC
4 Pages
-
NMT
2 Pages
-
NMC
4 Pages
-
NKP
2 Pages
-
NGS
8 Pages
-
NES
2 Pages
-
NEC
6 Pages
-
NCW
4 Pages
-
NBK
5 Pages
-
LNM
2 Pages
-
PUM
2 Pages
-
HND-P105
8 Pages
-
SEN-96
3 Pages
-
MAN-RF...M21..DRM-602
4 Pages
-
MAN-SD
4 Pages
-
SEN-86 AUF
6 Pages
-
SEN-3251 / 3252
3 Pages
-
SCH
21 Pages
-
PMP
2 Pages
-
PAD
23 Pages
-
DAK-1
6 Pages
-
DAT-1
6 Pages
-
DKB
3 Pages
-
DKF
2 Pages
-
DAA
2 Pages
-
DAR
6 Pages
-
DON-...LCD
10 Pages
-
EPS
7 Pages
-
BGN
6 Pages
-
MIK
7 Pages
-
MIM
10 Pages
-
TSK
6 Pages
-
DUC
13 Pages
-
VKP
2 Pages
-
VKM
7 Pages
-
VKG
7 Pages
-
URM
4 Pages
-
URK
4 Pages
-
TMU
13 Pages
-
TME
8 Pages
-
SMV
10 Pages
-
PSR
5 Pages
-
PPS
2 Pages
-
PIT
11 Pages
-
PEL-L
4 Pages
-
KSM
4 Pages
-
KDF/KDG
4 Pages
-
KAL-D
3 Pages
-
DWU
5 Pages
-
DWD
4 Pages
-
DVH / DVE
8 Pages
-
DVZ-E
9 Pages
-
DVK
6 Pages
-
DUK-C
7 Pages
-
KSR/SVN
2 Pages
-
DSV-3
4 Pages
-
DRH AUF
6 Pages
-
DPL-F
4 Pages
-
DPE-F
5 Pages
-
DOT
5 Pages
-
DMS
4 Pages
-
Program summary 2018
48 Pages
-
DON
9 Pages