Guided Wave Radar Level Transmitter (TDR) monitoring • analysing Independent of density, temperature, pressure, humidity and conductivity P robe length: max. 2000 mm for monoprobe and coaxialtube max. 4000mm for wire rope Output: 4 - 20 mA / 0 - 10 V switching output PNP or NPN KOBOLD companies worldwide: AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHINA, CZECHIA, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, Republic of Korea, ROMANIA, RUSSIA, SPAIN, SWITZERLAND, THAILAND, TUNISIA, turkey, USA, VIETNAM KOBOLD Messring GmbH Nordring 22-24 D-65719 Hofheim/Ts. Head Office: +49(0)6192 299-0 +49(0)6192 23398 info

Open the catalog to page 1
NGR - 2

Technical Details RoHS certificate: Accuracy of sensor element1): Repeatability: Resolution: Response time: Dielectric constant: Conductivity: Max. level change: Inactive area at probe end1): The NGR is a level sensor that uses TDR technology (time domain reflectometry) and thus can be used in oil- and water-based liquids without calibration. The NGR's guided radar uses time-offlight technology to measure electromagnetic pulses. The time difference between the sent pulse and the reflected pulse is used to calculate the level, both as a continuous value (analogue output) and a freely...

Open the catalog to page 2
NGR - 3

Guided Wave Radar Level Transmitter (TDR) Model NGR Hysteresis: Inductive load: Capacitive load: Enclosure rating: Temperature drift: Lower signal level: Upper signal level: EMC: Ambient operating temperature: Ambient storage temperature: Technical Details (continuation) Output signal3): analogue output 4 mA ... 20 mA / 0 V . 10 V automatic switching to a current or voltage output depending on the load. 1 PNP-transistor output and 1 PNP/NPN-transistor output switchable (Option 2) or 1 PNP-transistor output and 3 PNP/NPN-transistor output switchable (Option 4) Output load: 4 mA ..20 mA < 500...

Open the catalog to page 3
NGR - 4

Guided Wave Radar Level Transmitter (TDR) Model NGR Accuracy Diagrams [mm] Accuracy diagram with parameterized tank Accuracy diagram without parameterized tank Accuracy in mm Level in mm Accuracy in mm Level in mm Inactive area Reference conditions: Container with a diameter of 1 m Central installation of the sensor Minimum distance to built-in components > 300 mm Distance from the end of probe to tank bottom > 15 mm Air humidity: 65% +/- 20% Temperature: +20 °C +/- 5 °C Pressure: 1013 mbar abs. +/- 20 mbar. Container parameterization undertaken Medium: water, DK = 80 1 L+: supply voltage,...

Open the catalog to page 4
NGR - 5

Guided Wave Radar Level Transmitter (TDR) Model NGR with coax tube Wire probe with Coax tube M: measuring range L: probe length IA: inactive area at process connection 25 mm IAE: Inactive area at probe end 10 mm No responsibility taken for errors; subject to change without prior notice.

Open the catalog to page 5
NGR - 6

Guided Wave Radar Level Transmitter (TDR) Model NGR Installation in a tank Unit with mono probe mounted in metal tank Installation in nozzle: D >= DN 25 Distance tank wall/tank bottom: A >= 50 mm B >= 10 mm Distance to other tank fittings: >= 100 mm with coaxial tube mono probe Unit with coaxial tube for metal and non metal tank C = with a coaxial tube there are no minimum distances to the tank wall or to other tank fittings required Installation of a mono probe in a metal immersion tube or metal bypass D >= DN 40 Distance tank wall/tank bottom: B >= 10 mm bypass pipe. To do this, it is...

Open the catalog to page 6
NGR - 7

Guided Wave Radar Level Transmitter (TDR) Model NGR Rope probe in the metallic container Roper weight Bracket rope tension Installation in nozzle: D >= DN 25 Container wall / container bottom distance: A >= 50 mm Distance from components built into container: >= 100 mm Mounting the mono-probe M = Measuring range X = No measurement is possible in this area Container welding seams may affect the measurement accuracy. No responsibility taken for errors; subject to change without prior notice.

Open the catalog to page 7

All KOBOLD INSTRUMENTATION catalogs and technical brochures

  1. PSD

    7 Pages

  2. RFS

    2 Pages

  3. KES

    7 Pages

  4. BGN

    6 Pages

  5. MIK

    7 Pages

  6. DWF

    4 Pages

  7. ATA-K

    4 Pages

  8. HND-F

    7 Pages

  9. AFK-G2

    3 Pages

  10. HND-C

    3 Pages

  11. ACM-1

    6 Pages

  12. HND-R

    4 Pages

  13. APM-1

    6 Pages

  14. HND-T120

    10 Pages

  15. MWD

    21 Pages

  16. TNF

    6 Pages

  17. TNS

    6 Pages

  18. TWP

    4 Pages

  19. TDD-1

    3 Pages

  20. TWR

    2 Pages

  21. TSA

    2 Pages

  22. TRS

    2 Pages

  23. M

    23 Pages

  24. NSV

    4 Pages

  25. NIR-9

    5 Pages

  26. MM

    13 Pages

  27. NGM

    10 Pages

  28. NUS-4

    5 Pages

  29. NMF

    4 Pages

  30. PLS

    2 Pages

  31. PAS

    22 Pages

  32. NWS

    5 Pages

  33. NVI

    3 Pages

  34. NV

    2 Pages

  35. NTB

    3 Pages

  36. NSC

    4 Pages

  37. NMT

    2 Pages

  38. NMC

    4 Pages

  39. NKP

    2 Pages

  40. NGS

    8 Pages

  41. NES

    2 Pages

  42. NEC

    6 Pages

  43. NCW

    4 Pages

  44. NBK

    5 Pages

  45. LNM

    2 Pages

  46. PUM

    2 Pages

  47. HND-P105

    8 Pages

  48. SEN-96

    3 Pages

  49. MAN-SD

    4 Pages

  50. SEN-86 AUF

    6 Pages

  51. SCH

    21 Pages

  52. PMP

    2 Pages

  53. PAD

    23 Pages

  54. DAK-1

    6 Pages

  55. DAT-1

    6 Pages

  56. DKB

    3 Pages

  57. DKF

    2 Pages

  58. DAA

    2 Pages

  59. DAR

    6 Pages

  60. BGF

    6 Pages

  61. DON-...LCD

    10 Pages

  62. KDS

    6 Pages

  63. EPS

    7 Pages

  64. BGN

    6 Pages

  65. MIK

    7 Pages

  66. MIM

    10 Pages

  67. TSK

    6 Pages

  68. DUC

    13 Pages

  69. VKP

    2 Pages

  70. VKM

    7 Pages

  71. VKG

    7 Pages

  72. URM

    4 Pages

  73. URK

    4 Pages

  74. TMU

    13 Pages

  75. TME

    8 Pages

  76. SMV

    10 Pages

  77. PSR

    5 Pages

  78. PPS

    2 Pages

  79. PIT

    11 Pages

  80. PEL-L

    4 Pages

  81. KSM

    4 Pages

  82. KDF/KDG

    4 Pages

  83. KAL-D

    3 Pages

  84. DWU

    5 Pages

  85. DWD

    4 Pages

  86. DVH / DVE

    8 Pages

  87. DVZ-E

    9 Pages

  88. DVK

    6 Pages

  89. DUK-C

    7 Pages

  90. KSR/SVN

    2 Pages

  91. DSV-3

    4 Pages

  92. DRH AUF

    6 Pages

  93. DPL-F

    4 Pages

  94. DPE-F

    5 Pages

  95. DOT

    5 Pages

  96. DMS

    4 Pages

  97. KDS

    5 Pages

  98. BGF

    6 Pages

  99. DON

    9 Pages