Group: Kobold
Catalog excerpts
Industrial Resistance Thermometers according to DIN measuring monitoring analysing • Measuring range: -198 ... +600 °C • Pt100 sensor: class A, class B, class 1/3, class 1/10, or cryogenic • Output: resistance or analogue 4 ... 20 mA • Option: head transmitter with HART® -protocol or Profibus® /Fieldbus®, display • Protection tube/ measuring insert material: stainless steel 1.4404, others on request KOBOLD companies worldwide: AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHINA, CZECHIA, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, REPUBLIC OF KOREA, ROMANIA, RUSSIA, SPAIN, SWITZERLAND, THAILAND, TUNISIA, TURKEY, USA, VIETNAM KOBOLD Messring GmbH Nordring 22-24 D-65719 Hofheim/Ts. V* Head Office: +49(0)6192 299-0 +49(0)6192 23398 info.de@kobold.com www.kobold.com
Open the catalog to page 1Industrial Resistance Thermometers according to DIN Model MWD Materials: Sensor: Connection head: Terminal block: Process connection: Thread: DIN-flange: ANSI flange: Max. pressure: Sensor wiring: Description KOBOLD temperature assemblies comprise a rugged installation fitting made of stainless steel with thread, flange or weld-on process connection, a connection head and a measuring element. A Pt100 temperature sensor according to IEC 751, class A, B, V3 DIN or V10 is fitted in the measuring element. On request, the measuring element can be removable, thus, allowing to remove the measuring...
Open the catalog to page 2Industrial Resistance Thermometers according to DIN Model MWD Model MWD-A compact compression fitting Specifications: Sensor element: Pt 100 3-wire class B, A, 1/3, 1/io, cryogenic, and others Electrical connection: M20x1.5 Max. pressure: 30 bar (at 20 °C) Protection tube: according to DIN 43772, filled with magnesium oxide (MgO) Material: stainless steel 1.4404 (316L) 1 Only with head transmitter option 0 2) Please specify the measuring range in clear text, while ordering 3) With 1x Pt100 only 4) For options A, B, C, D choose RTD wiring code »3« Note: Please specify length »EL« in clear...
Open the catalog to page 3Industrial Resistance Thermometers according to DIN Model MWD Model MWD-L compact fixed thread Specifications: Sensor element: Pt100 3-wire class B, A, 1/3, 1/io, cryogenic, and others Electrical connection: M20x1.5 Max. pressure: 30 bar (at 20 °C) Protection tube: according to DIN 43772, filled with magnesium oxide (MgO) Material: stainless steel 1.4404 (316L) 1 Only with head transmitter option 0 2 Please specify the measuring range in clear text, while ordering 3) With 1x Pt100 only 4) For options A, B, C, D choose RTD wiring code '3' Note: Please specify length ‘EL‘ in clear text, while...
Open the catalog to page 4Industrial Resistance Thermometers according to DIN Model MWD Model MWD-B compact threaded or flanged with neck pipe Specifications: Sensor element: Pt100 3-wire class B, A, 1/3, 1/io, cryogenic, and others Neck pipe HL: 130 mm Electrical connection: M20x1.5 Max. pressure: 30 bar (at 20 °C) Protection tube: according to DIN 43772, filled with magnesium oxide (MgO) Material: stainless steel 1.4404 (316L) 11 Only with head transmitter option 0 2 Please specify the measuring range in clear text, while ordering 3) With 1x Pt100 only 4) For options A, B, C, D choose RTD wiring code '3' Note:...
Open the catalog to page 5Max. pressure: Protection tube: Material: Measuring insert: Industrial Resistance Thermometers according to DIN Model MWD Model MWD-C compact with removable measuring insert Specifications: Sensor element: Pt100 3-wire class B, A, 1/3, 1/io, cryogenic, and others Electrical connection: M20x1.5 30 bar (at 20 °C) according to DIN 43772 stainless steel 1.4404 (316L) filled with magnesium oxide (MgO) 1 Only with head transmitter option 0 2 Please specify the measuring range in clear text, while ordering 3) With 1x Pt100 only 4) For options A, B, C, D choose RTD wiring code '3' Note: Please...
Open the catalog to page 6Industrial Resistance Thermometers according to DIN Model MWD Model MWD-E compact with removable measuring insert and compressing fitting Specifications: Sensor element: cryogenic, and others Electrical connection: M20x1.5 Max. pressure: Protection tube: Material: Measuring insert: 30 bar (at 20 °C) according to DIN 43772 stainless steel 1.4404 (316L) filled with magnesium oxide (MgO) 1) Only with head transmitter option 0 2) Please specify the measuring range in clear text, while ordering 3) With 1x Pt100 only 4) For options A, B, C, D choose RTD wiring code '3' Note: Please specify length...
Open the catalog to page 7Industrial Resistance Thermometers according to DIN Model MWD Model MWD-D compact with removable measuring insert and extension neck pipe Specifications: Sensor element: Pt100 3-wire class B, A, 1/3, 1/io, cryogenic, and others Neck pipe HL: 130 mm Electrical connection: M20x1.5 Max. pressure: 30 bar (at 20 °C) Protection tube: according to DIN 43772 Material: stainless steel 1.4404 (316L) Measuring insert: filled with magnesium oxide (MgO) 1 Only with head transmitter option 0 2) Please specify the measuring range in clear text, while ordering 3) With 1x Pt100 only 4) For options A, B, C,...
Open the catalog to page 8Industrial Resistance Thermometers according to DIN Model MWD Model MWD-F compact fixed thread with removable measuring insert^, for mounting in thermowell Specifications: Sensor element: Pt100 3-wire class B, A, 1/3, 1/io, cryogenic, and others Process connection: threaded Electrical connection: M20x1.5 Max. pressure: Patm only with thermowell TWL-0 Measuring insert: according to DIN 43772, filled with magnesium oxide (MgO) Material: stainless steel 1.4404 (316L) 1 Only with head transmitter option 0 2 Please specify the measuring range in clear text, while ordering 3) With 1x Pt100 only...
Open the catalog to page 9Industrial Resistance Thermometers according to DIN Model MWD Model MWD-G compact with removable measuring insert1’ and neck pipe, for mounting in thermowell Specifications: Sensor element: Pt100 3-wire class B, A, 1/3, V10, cryogenic, and others Neck pipe HL: 130 mm Electrical connection: M20x1.5 Max. pressure: Patm only with thermowell TWL-0 Measuring insert: according to DIN 43772, filled with magnesium oxide (MgO) Material: stainless steel 1.4404 (316L) Note: For order details of the thermowell see datasheet TWL-0. Without thermowell atmospheric pressure. 11 Without protection tube 11...
Open the catalog to page 10All KOBOLD INSTRUMENTATION catalogs and technical brochures
-
PSD
7 Pages
-
RFS
2 Pages
-
KES
7 Pages
-
BGN
6 Pages
-
MIK
7 Pages
-
DWF
4 Pages
-
ATA-K
4 Pages
-
HND-F
7 Pages
-
AFK-G2
3 Pages
-
HND-C
3 Pages
-
ACM-1
6 Pages
-
HND-R
4 Pages
-
APM-1
6 Pages
-
HND-T120
10 Pages
-
TNF
6 Pages
-
TNS
6 Pages
-
TWP
4 Pages
-
TDD-1
3 Pages
-
TWR
2 Pages
-
TSA
2 Pages
-
TRS
2 Pages
-
M
23 Pages
-
NSV
4 Pages
-
NIR-9
5 Pages
-
MM
13 Pages
-
NGM
10 Pages
-
NUS-4
5 Pages
-
NMF
4 Pages
-
NGR
7 Pages
-
PLS
2 Pages
-
PAS
22 Pages
-
NWS
5 Pages
-
NVI
3 Pages
-
NV
2 Pages
-
NTB
3 Pages
-
NSC
4 Pages
-
NMT
2 Pages
-
NMC
4 Pages
-
NKP
2 Pages
-
NGS
8 Pages
-
NES
2 Pages
-
NEC
6 Pages
-
NCW
4 Pages
-
NBK
5 Pages
-
LNM
2 Pages
-
PUM
2 Pages
-
HND-P105
8 Pages
-
SEN-96
3 Pages
-
MAN-RF...M21..DRM-602
4 Pages
-
MAN-SD
4 Pages
-
SEN-86 AUF
6 Pages
-
SEN-3251 / 3252
3 Pages
-
SCH
21 Pages
-
PMP
2 Pages
-
PAD
23 Pages
-
DAK-1
6 Pages
-
DAT-1
6 Pages
-
DKB
3 Pages
-
DKF
2 Pages
-
DAA
2 Pages
-
DAR
6 Pages
-
BGF
6 Pages
-
DON-...LCD
10 Pages
-
KDS
6 Pages
-
EPS
7 Pages
-
BGN
6 Pages
-
MIK
7 Pages
-
MIM
10 Pages
-
TSK
6 Pages
-
DUC
13 Pages
-
VKP
2 Pages
-
VKM
7 Pages
-
VKG
7 Pages
-
URM
4 Pages
-
URK
4 Pages
-
TMU
13 Pages
-
TME
8 Pages
-
SMV
10 Pages
-
PSR
5 Pages
-
PPS
2 Pages
-
PIT
11 Pages
-
PEL-L
4 Pages
-
KSM
4 Pages
-
KDF/KDG
4 Pages
-
KAL-D
3 Pages
-
DWU
5 Pages
-
DWD
4 Pages
-
DVH / DVE
8 Pages
-
DVZ-E
9 Pages
-
DVK
6 Pages
-
DUK-C
7 Pages
-
KSR/SVN
2 Pages
-
DSV-3
4 Pages
-
DRH AUF
6 Pages
-
DPL-F
4 Pages
-
DPE-F
5 Pages
-
DOT
5 Pages
-
DMS
4 Pages
-
Program summary 2018
48 Pages
-
KDS
5 Pages
-
BGF
6 Pages
-
DON
9 Pages