EPS
7Pages

{{requestButtons}}

Catalog excerpts

EPS - 1

Electromagnetic Flowmeter Accuracy: ± 0.3% of reading ± 0.01% x Qmax C onnection: flange DN 10 ... 1200, ANSI ½" ... 48" Lining material: hard rubber, soft rubber, PTFE / PFA Outputs: analogue with HART®, pulses and status OO KOBOLD companies worldwide: ARGENTINA, AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLoMBIA, CZECHIA, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, Republic of Korea, ROMANIA, SINGAPORE, SPAIN, SWITZERLAND, TAIWAN, THAILAND, TUNISIA, turkey, USA, VIETNAM KOBOLD Messring GmbH Nordring 22-24 D-65719 Hofheim/Ts. Head Office: +49(0)6192 299-0 +49(0)6192 23398 info.d

Open the catalog to page 1
EPS - 2

Electromagnetic Flowmeter Model DMH Description The KOBOLD DMH flowmeter is used to measure and monitor the volume flow rate of fluids, pulps, pastes and other electrically conductive materials, without loss of pressure. When an electrically conductive medium passes through a directional magnetic field, a voltage is induced in accordance with Faraday’s Law of Induction. The size of this measurement voltage is proportional to the mean rate of flow and consequently also to the volume flow rate. A flowmeter consists of a sensor that picks up the measuring signal generated from the induced...

Open the catalog to page 2
EPS - 3

Electromagnetic Flowmeter Model DMH compact or separate enamelled die-cast aluminium 115 VAC 50 / 60 Hz, 10 VA 230 VAC, 50 / 60 Hz, 10 VA 24 VDC 10 W Technical Details(continued) Transducer UMF2(B) Assembly type: Housing: Power supply: Outputs Analogue: Pulse output: Status: 1 x 0(4)-20 mA, active, galvanically isolated passive, galvanically isolated 24 V, 60 mA passive, galvanically isolated 24 V, 60 mA depending on process temperature for compact version Protection type: IP 68 (EN60529) Communication: HART® Diagnosis functions: empty pipe recognition, flushing flow monitoring...

Open the catalog to page 3
EPS - 4

Electromagnetic Flowmeter Model DMH SiMeasuring Range Flange DN * Unit with PFA-lining, with 6, 8 and 10 mm tube No responsibility taken for errors; subject to change without prior notice.

Open the catalog to page 4
EPS - 5

Order Details (Example: DMH-1 A15 H 1 0 A 1 0) Model/ flange-material Process connection11 (flange acc. to EN 1092-1 Form B1) Lining Measuring electrode material9) Versions/ cable lengths Electronics Power supply/ cable entry point DMH-1 = enamelled steel DMH-2 = stainless steel 1.4301 DMH-52)= wafer version H6) =hard rubber W6) = soft rubber T7) = PTFE/ PFA 1 = stainless steel 3 = Hastel-loy® C4 4 = Titan 5 = tantalum 7 = platinum 08) = without 1 = stainless steel 3 = Hastel-loy® C4 4 = Titan 5 = tantalum 7 = platinum ... H, IP 67 separate version/2.5 m separate version/5 m separate...

Open the catalog to page 5
EPS - 6

Electromagnetic Flowmeter Model DMH Connection box for sensor, separate version * Weights of the sensors are only approximate values, including the weight of the electronics approx. 2.4 kg No responsibility taken for errors; subject to change without prior notice.

Open the catalog to page 6
EPS - 7

Dimensions (continuation) Sensor, wafer flange * Weights of the sensors are only approximate values, including the weight of the electronics approx. 2.4 kg No responsibility taken for errors; subject to change without prior notice.

Open the catalog to page 7

All KOBOLD INSTRUMENTATION catalogs and technical brochures

  1. PSD

    7 Pages

  2. RFS

    2 Pages

  3. KES

    7 Pages

  4. BGN

    6 Pages

  5. MIK

    7 Pages

  6. DWF

    4 Pages

  7. ATA-K

    4 Pages

  8. HND-F

    7 Pages

  9. AFK-G2

    3 Pages

  10. HND-C

    3 Pages

  11. ACM-1

    6 Pages

  12. HND-R

    4 Pages

  13. APM-1

    6 Pages

  14. HND-T120

    10 Pages

  15. MWD

    21 Pages

  16. TNF

    6 Pages

  17. TNS

    6 Pages

  18. TWP

    4 Pages

  19. TDD-1

    3 Pages

  20. TWR

    2 Pages

  21. TSA

    2 Pages

  22. TRS

    2 Pages

  23. M

    23 Pages

  24. NSV

    4 Pages

  25. NIR-9

    5 Pages

  26. MM

    13 Pages

  27. NGM

    10 Pages

  28. NUS-4

    5 Pages

  29. NMF

    4 Pages

  30. NGR

    7 Pages

  31. PLS

    2 Pages

  32. PAS

    22 Pages

  33. NWS

    5 Pages

  34. NVI

    3 Pages

  35. NV

    2 Pages

  36. NTB

    3 Pages

  37. NSC

    4 Pages

  38. NMT

    2 Pages

  39. NMC

    4 Pages

  40. NKP

    2 Pages

  41. NGS

    8 Pages

  42. NES

    2 Pages

  43. NEC

    6 Pages

  44. NCW

    4 Pages

  45. NBK

    5 Pages

  46. LNM

    2 Pages

  47. PUM

    2 Pages

  48. HND-P105

    8 Pages

  49. SEN-96

    3 Pages

  50. MAN-SD

    4 Pages

  51. SEN-86 AUF

    6 Pages

  52. SCH

    21 Pages

  53. PMP

    2 Pages

  54. PAD

    23 Pages

  55. DAK-1

    6 Pages

  56. DAT-1

    6 Pages

  57. DKB

    3 Pages

  58. DKF

    2 Pages

  59. DAA

    2 Pages

  60. DAR

    6 Pages

  61. BGF

    6 Pages

  62. DON-...LCD

    10 Pages

  63. KDS

    6 Pages

  64. BGN

    6 Pages

  65. MIK

    7 Pages

  66. MIM

    10 Pages

  67. TSK

    6 Pages

  68. DUC

    13 Pages

  69. VKP

    2 Pages

  70. VKM

    7 Pages

  71. VKG

    7 Pages

  72. URM

    4 Pages

  73. URK

    4 Pages

  74. TMU

    13 Pages

  75. TME

    8 Pages

  76. SMV

    10 Pages

  77. PSR

    5 Pages

  78. PPS

    2 Pages

  79. PIT

    11 Pages

  80. PEL-L

    4 Pages

  81. KSM

    4 Pages

  82. KDF/KDG

    4 Pages

  83. KAL-D

    3 Pages

  84. DWU

    5 Pages

  85. DWD

    4 Pages

  86. DVH / DVE

    8 Pages

  87. DVZ-E

    9 Pages

  88. DVK

    6 Pages

  89. DUK-C

    7 Pages

  90. KSR/SVN

    2 Pages

  91. DSV-3

    4 Pages

  92. DRH AUF

    6 Pages

  93. DPL-F

    4 Pages

  94. DPE-F

    5 Pages

  95. DOT

    5 Pages

  96. DMS

    4 Pages

  97. KDS

    5 Pages

  98. BGF

    6 Pages

  99. DON

    9 Pages