Group: Kobold
Catalog excerpts
Vortex Flowmeter Compact Accuracy: ±2.5 % of full scale Connection material: brass or stainless steel O utput: switching output, frequency output, analogue output C ompact, counter and dosing electronics KOBOLD companies worldwide: ARGENTINA, AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLoMBIA, CZECHIA, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, Republic of Korea, ROMANIA, SINGAPORE, SPAIN, SWITZERLAND, TAIWAN, THAILAND, TUNISIA, turkey, USA, VIETNAM KOBOLD Messring GmbH Nordring 22-24 D-65719 Hofheim/Ts. Head Office: +49(0)6192 299-0 +49(0)6192 23398 info.
Open the catalog to page 1Vortex Flowmeter Compact Model DVZ vortex principle any, flow in direction of arrow ±2.5 % of full scale ±1 % of full scale 10 x DN / 2 x DN 0 ... 80 °C -10 ... +60 °C see table Measur. range When using viscous media the decreased Reynolds number causes a displacement of the measuring range start point to higher values. The measuring range end points values however stays unchanged. Wetted parts Sensor housing: Sensor: Connections: Bluff body: Seal: Response time: Protection: Weight: Description The compact KOBOLD Vortex flowmeter Model DVZ is used for measuring and monitoring smaller and...
Open the catalog to page 2Vortex Flowmeter Compact Model DVZ Technical Details (continuation) DVZ-...S300, DVZ-...S30D Display: DUO-LED for switching condition and when range limit is exceeded Switching output: relay change over, max.1 A/30 VDC or active 24 VDC, N/C / N/O Switch point: 10 ... 90 % of full scale in 10 %-steps that can be configured by the customer using a rotary switch Power supply: 24 VDC ±20 % Power consumption: 25 mA Electrical connection: plug M12 x 1.5 pole Measuring range overflow: flash of the DUO-LED (green/red) from 105 % of full scale DVZ-...F300, DVZ...F390 Pulse output: PNP, Open...
Open the catalog to page 3Technical Details (continuation) DVZ-...Exxx (Counter electronics) Quantity meter: Analogue output: Load: Switching output: Settings: Functions: Power supply: Power consumption: Electrical connection: LCD, 2 x 8 digit, illuminated total, part and flow quantities, units selectable 8-digit 0(4)...20 mA adjustable max. 500 Q 2 relays, max. 30 VAC/DC / 2 A / 60 VA via 4 buttons reset, MIN /MAX memory, flow monitor, monitoring for part and total quantity, language 24 VDC ±20 %, 3-wire technology approx. 150 mA cable connection or M 12-plug More technical details see data sheet ZED. DVZ-...Gxxx...
Open the catalog to page 4Vortex Flowmeter Compact Model DVZ Order Details (Example: DVZ-1 1 04 G2 S300) No responsibility taken for errors; subject to change without prior notice.
Open the catalog to page 5No responsibility taken for errors; subject to change without prior notice.
Open the catalog to page 6Vortex Flowmeter Compact Model DVZDVZ sensor with reinforced connection Measuring range up to 32 l/minDVZ sensor with reinforced connection Measuring range from 40 l/min MB No responsibility taken for errors; subject to change without prior notice.
Open the catalog to page 7No responsibility taken for errors; subject to change without prior notice.
Open the catalog to page 8Vortex Flowmeter Compact Model DVZ No responsibility taken for errors; subject to change without prior notice.
Open the catalog to page 9All KOBOLD INSTRUMENTATION catalogs and technical brochures
-
PSD
7 Pages
-
RFS
2 Pages
-
KES
7 Pages
-
BGN
6 Pages
-
MIK
7 Pages
-
DWF
4 Pages
-
ATA-K
4 Pages
-
HND-F
7 Pages
-
AFK-G2
3 Pages
-
HND-C
3 Pages
-
ACM-1
6 Pages
-
HND-R
4 Pages
-
APM-1
6 Pages
-
HND-T120
10 Pages
-
MWD
21 Pages
-
TNF
6 Pages
-
TNS
6 Pages
-
TWP
4 Pages
-
TDD-1
3 Pages
-
TWR
2 Pages
-
TSA
2 Pages
-
TRS
2 Pages
-
M
23 Pages
-
NSV
4 Pages
-
NIR-9
5 Pages
-
MM
13 Pages
-
NGM
10 Pages
-
NUS-4
5 Pages
-
NMF
4 Pages
-
NGR
7 Pages
-
PLS
2 Pages
-
PAS
22 Pages
-
NWS
5 Pages
-
NVI
3 Pages
-
NV
2 Pages
-
NTB
3 Pages
-
NSC
4 Pages
-
NMT
2 Pages
-
NMC
4 Pages
-
NKP
2 Pages
-
NGS
8 Pages
-
NES
2 Pages
-
NEC
6 Pages
-
NCW
4 Pages
-
NBK
5 Pages
-
LNM
2 Pages
-
PUM
2 Pages
-
HND-P105
8 Pages
-
SEN-96
3 Pages
-
MAN-RF...M21..DRM-602
4 Pages
-
MAN-SD
4 Pages
-
SEN-86 AUF
6 Pages
-
SEN-3251 / 3252
3 Pages
-
SCH
21 Pages
-
PMP
2 Pages
-
PAD
23 Pages
-
DAK-1
6 Pages
-
DAT-1
6 Pages
-
DKB
3 Pages
-
DKF
2 Pages
-
DAA
2 Pages
-
DAR
6 Pages
-
BGF
6 Pages
-
DON-...LCD
10 Pages
-
KDS
6 Pages
-
EPS
7 Pages
-
BGN
6 Pages
-
MIK
7 Pages
-
MIM
10 Pages
-
TSK
6 Pages
-
DUC
13 Pages
-
VKP
2 Pages
-
VKM
7 Pages
-
VKG
7 Pages
-
URM
4 Pages
-
URK
4 Pages
-
TMU
13 Pages
-
TME
8 Pages
-
SMV
10 Pages
-
PSR
5 Pages
-
PPS
2 Pages
-
PIT
11 Pages
-
PEL-L
4 Pages
-
KSM
4 Pages
-
KDF/KDG
4 Pages
-
KAL-D
3 Pages
-
DWU
5 Pages
-
DWD
4 Pages
-
DVH / DVE
8 Pages
-
DVK
6 Pages
-
DUK-C
7 Pages
-
KSR/SVN
2 Pages
-
DSV-3
4 Pages
-
DRH AUF
6 Pages
-
DPL-F
4 Pages
-
DPE-F
5 Pages
-
DOT
5 Pages
-
DMS
4 Pages
-
Program summary 2018
48 Pages
-
KDS
5 Pages
-
BGF
6 Pages
-
DON
9 Pages