APM-1
6Pages

{{requestButtons}}

Catalog excerpts

APM-1 - 1

for pH-Value, Redox, Standard signals and Temperature Measuring range: pH: -2 ... 16 Redox: -1500 ... +1500 mV Temperature: Pt100 / Pt1000: -50 ... +250 °C NTC/PTC: 0.1 ... 30 kΩ Standard signal: 0(4) ... 20 mA, 0 - 10 V Resistance: min. 100 Ω, max. 3 kΩ Input (standard) 1 x pH or redox and 1 x temperature/resistance or standard signal and 2 x binary inputs Output (standard) 2 x relay (changeover contact) 1 x power supply for 2-wire sensor 17 VDC 3 plug-in boards (optional retrofit) - relay (changeover contact) - double relay (2 x NO, common pin) - 1 x analogue output 0(4) ... 20 mA, 0(2) ... 10 V - 1 x semiconductor relay TRIAC, 1 A - 2 x semiconductor switch (Photo-Mos) - supply voltage for sensor ± 5 VDC - supply voltage for sensor + 12 VDC - interface RS 485 - datalogger with RS 485 and real time clock - Profibus DP Freely programmable via keys or by optional software Programmable backlight graphic display (1, 2 or 3 display values, trend display, bargraph, trend curve) Calibration routines, wash timer Math and logic module 13 operator languages integrated KOBOLD companies worldwide: ARGENTINA, AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLoMBIA, CZECHIA, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, Republic of Korea, ROMANIA, SINGAPORE, SPAIN, SWITZERLAND, TAIWAN, THAILAND, TUNISIA, turkey, USA, VIETNAM KOBOLD Messring GmbH Nordring 22-24 D-65719 Hofheim/Ts. Head Office: +49(0)

Open the catalog to page 1
APM-1 - 2

Transmitter/Controller for pH-Value, Redox, Standard signals and Temperature Model APM-1 Description The compact transmitter /controller APM-1.. measures and controls the pH value or redox potential in aqueous solutions. It is available as panel-mounted device according to DIN/EN 61554 or as field housing. Measured values and parameters are displayed on a high-contrast graphic display in plain text. Easy configuration via buttons or PC with optional software provide a simple and user friendly operation. An integrated math and logic module enables the integration of the measured values i n...

Open the catalog to page 2
APM-1 - 3

Transmitter/Controller for pH-Value, Redox, Standard signals and Temperature Model APM-1 Calibration For units with additional plug-in boards the following calibration options are possible: Zero point, limit value, zero point and limit value, cell constant, temperature coefficient. Linear scaling With function "linear scaling" the input signal can be displayed linearly. The following units are available: µS/cm, mS/cm, %, mV, pH, ppm, customised up to 5 characters. Customised with table Nonlinear relationships between input and output size can be processed. E. g. Content of horizontal...

Open the catalog to page 3
APM-1 - 4

Transmitter/Controller for pH-Value, Redox, Standard signals and Temperature Model APM-1 Technical Data (suite) Outputs (standard) 2 relay (changeover contact) Contact rating: 5 A at 240 VAC resistive load Contact service life: 350 000 operations at nominal load 750 000 operations at 1A Sensor supply for 2-wire transmitter 17 VDC at 20 mA, open-circuit voltage approx. 25 VDC Controller (standard) (see manual for configuration examples) Controller type: Limit comparators, limit controllers, pulse length controllers, pulse frequency controllers, modulating controllers, continuous controllers...

Open the catalog to page 4
APM-1 - 5

Transmitter/Controller for pH-Value, Redox, Standard signals and Temperature Model APM-1Order Details (Example: APM-1 E 1 0 0 0 Y) Model 11 The readout of data is only possible with the PC setup software! Note: All languages are available in the device menu and can be changed by the customer at any time. The factory default setting of a language (except for "German") entail additional costs. Accessories for transmitter APM-1 and ACM-1 Version Electrical connection (For details see manual or configuration sheet) Option slct 3 Option'sfot 2 Option slot 1 No responsibility taken for errors;...

Open the catalog to page 5
APM-1 - 6

Transmitter/Controller for pH-Value, Redox, Standard signals and Temperature Model APM-1 Dimensions Panel Mounting Panel cut-out No responsibility taken for errors; subject to change without prior notice.

Open the catalog to page 6

All KOBOLD INSTRUMENTATION catalogs and technical brochures

  1. PSD

    7 Pages

  2. RFS

    2 Pages

  3. KES

    7 Pages

  4. BGN

    6 Pages

  5. MIK

    7 Pages

  6. DWF

    4 Pages

  7. ATA-K

    4 Pages

  8. HND-F

    7 Pages

  9. AFK-G2

    3 Pages

  10. HND-C

    3 Pages

  11. ACM-1

    6 Pages

  12. HND-R

    4 Pages

  13. HND-T120

    10 Pages

  14. MWD

    21 Pages

  15. TNF

    6 Pages

  16. TNS

    6 Pages

  17. TWP

    4 Pages

  18. TDD-1

    3 Pages

  19. TWR

    2 Pages

  20. TSA

    2 Pages

  21. TRS

    2 Pages

  22. M

    23 Pages

  23. NSV

    4 Pages

  24. NIR-9

    5 Pages

  25. MM

    13 Pages

  26. NGM

    10 Pages

  27. NUS-4

    5 Pages

  28. NMF

    4 Pages

  29. NGR

    7 Pages

  30. PLS

    2 Pages

  31. PAS

    22 Pages

  32. NWS

    5 Pages

  33. NVI

    3 Pages

  34. NV

    2 Pages

  35. NTB

    3 Pages

  36. NSC

    4 Pages

  37. NMT

    2 Pages

  38. NMC

    4 Pages

  39. NKP

    2 Pages

  40. NGS

    8 Pages

  41. NES

    2 Pages

  42. NEC

    6 Pages

  43. NCW

    4 Pages

  44. NBK

    5 Pages

  45. LNM

    2 Pages

  46. PUM

    2 Pages

  47. HND-P105

    8 Pages

  48. SEN-96

    3 Pages

  49. MAN-SD

    4 Pages

  50. SEN-86 AUF

    6 Pages

  51. SCH

    21 Pages

  52. PMP

    2 Pages

  53. PAD

    23 Pages

  54. DAK-1

    6 Pages

  55. DAT-1

    6 Pages

  56. DKB

    3 Pages

  57. DKF

    2 Pages

  58. DAA

    2 Pages

  59. DAR

    6 Pages

  60. BGF

    6 Pages

  61. DON-...LCD

    10 Pages

  62. KDS

    6 Pages

  63. EPS

    7 Pages

  64. BGN

    6 Pages

  65. MIK

    7 Pages

  66. MIM

    10 Pages

  67. TSK

    6 Pages

  68. DUC

    13 Pages

  69. VKP

    2 Pages

  70. VKM

    7 Pages

  71. VKG

    7 Pages

  72. URM

    4 Pages

  73. URK

    4 Pages

  74. TMU

    13 Pages

  75. TME

    8 Pages

  76. SMV

    10 Pages

  77. PSR

    5 Pages

  78. PPS

    2 Pages

  79. PIT

    11 Pages

  80. PEL-L

    4 Pages

  81. KSM

    4 Pages

  82. KDF/KDG

    4 Pages

  83. KAL-D

    3 Pages

  84. DWU

    5 Pages

  85. DWD

    4 Pages

  86. DVH / DVE

    8 Pages

  87. DVZ-E

    9 Pages

  88. DVK

    6 Pages

  89. DUK-C

    7 Pages

  90. KSR/SVN

    2 Pages

  91. DSV-3

    4 Pages

  92. DRH AUF

    6 Pages

  93. DPL-F

    4 Pages

  94. DPE-F

    5 Pages

  95. DOT

    5 Pages

  96. DMS

    4 Pages

  97. KDS

    5 Pages

  98. BGF

    6 Pages

  99. DON

    9 Pages