KNF LABORATORY EQUIPMENT KNOWING WHAT COUNTS
Open the catalog to page 1KNF LABORATORY EQUIPMENT – RETHINKING EVERYDAY LAB WORK 4 MODULAR VACUUM PUMP SYSTEMS 8 ROTARY EVAPORATION/ DISTILLATION CENTRIFUGAL CONCENTRATION VACUUM OVEN MULTI-USER VACUUM SYSTEMS METERING/DOSING LIQUIDS LIQUID TRANSFER TECHNICAL SPECIFICATIONS KNF is always looking for ways to minimize the challenges of everyday laboratory tasks through user-friendly equipment. That is why KNF designs compact devices with intuitive interfaces and intelligent functions with clear advantages. They are quiet, efficient and completely reliable. Lab technology that supports you.
Open the catalog to page 2MODULAR VACUUM PUMP SYSTEMS MODULAR VACUUM PUMP SYSTEMS LABOPORT® – MODULAR AND EXPANDABLE HELLO, NEW LABOPORT SYSTEMS! The new laboratory vacuum pump system guarantees maximum performance and safety in the laboratory, tailored to your individual needs: The powerful basic pump can be easily modified to an even higher environmentally friendly system. Various system components such as a separator, high-performance condenser and the new vacuum controller, allows the systems to be used for a wide range of laboratory applications. Simple, safe and precise n Automatic, accurate recognition and monitoring...
Open the catalog to page 3MODULAR VACUUM PUMP SYSTEMS ireless remote control for safe W operation from outside closed fume hoods n Clear overview Touch screen display and precise control for easy and intuitive operation n Wide range of applications Four operation modes that cover almost all common laboratory applications MODULAR VACUUM PUMP SYSTEMS LABOPORT® – SMART CONTROL Our new laboratory vacuum pump systems provide continuous control, making your lab even safer, more efficient and user-friendly. The most recent highlight in our range is the vacuum control unit with wireless remote control for the SC 820 G and SC...
Open the catalog to page 4ROTARY EVAPORATION/DISTILLATION The most important considerations when choosing a rotary evaporator All KNF pumps are chemical-resistant, offer a high vapor compatibility and feature a gas ballast. There are three key parameters to consider when selecting an appropriate vacuum system. Firstly, the performance of the vacuum system is dependent on the volume of the evaporating flask used. The larger the volume, the higher the flow rate required. Beyond this, it is necessary to consider the ultimate vacuum required for the evaporation process, as well as whether or not a remote control is required....
Open the catalog to page 5ROTARY EVAPORATION/DISTILLATION ROTARY EVAPORATION/DISTILLATION Evaporating flask volume 5: 6 mbar abs. ■ Flow rate: 20 l/min ■ Ultimate vacuum: 6 mbar abs. ■ Adjustable motor speed control ■ Ideal for solvents with high boiling points (e.g. DMF DMSO) ■ Incl. wireless controller with touch screen Evaporating flask volume 5: 6 mbar abs. ■ Flow rate: 34 l/min ■ Ultimate vacuum: 6 mbar abs. ■ Adjustable motor speed control ■ Ideal for solvents with high boiling points (e.g. DMF, DMSO) ■ Incl. wireless controller with touch screen Evaporating flask volume £ 2 mbar abs. ■ Flow rate: 21 l/min ■ Ultimate...
Open the catalog to page 6ROTARY EVAPORATION/DISTILLATION Rotary Evaporator ROTARY EVAPORATION/DISTILLATION Flexible options igital display for intuitive operation D Wide rotation speed: 5 – 315 rpm Two compact heating baths with digital display available (Water bath standard 10 – 90 °C, optional oil bath 10 – 180 °C) Possibility to place the heating bath on the right or left side Optional protective cover for heating bath Robust, chemical-resistant vacuum seal Designed to provide you with the best value: Choose from two system packages to suit your budget. More information The RE 212 FW-G rotary evaporator combined with...
Open the catalog to page 7The relevance of the right vacuum level... All KNF pumps are chemical-resistant and have a high vapor compatibility. The efficiency of vacuum filtration can be affected by a number of different factors, including the porosity of the filter, the viscosity of the liquid to be filtered and the type of particle to be removed. When choosing a vacuum pump, it is important to consider the volume of your flask and the number of filtration units (here referred to as “funnels”). A vacuum that is too weak will cause the process to take more time, while a vacuum that is too strong can lead to the filter...
Open the catalog to page 8Diaphragm Vacuum Pump LABOPORT® N 938.50 KT.18 ■ Flow rate: 30 l/min ■ Ultimate vacuum: 15 mbar abs. ■ Optional fine control valve (suction side) available Diaphragm Vacuum Pump LABOPORT® N 840 G ■ Flow rate: 34 l/min ■ Ultimate vacuum: 6 mbar abs. ■ Adjustable motor speed control ■ High condensate and vapor compatibility
Open the catalog to page 9SPE/SOLID PHASE EXTRACTION An ideal solution from KNF SPE/SOLID-PHASE EXTRACTION Solid-phase extraction is a common method of sample preparation where compounds are dissolved in a liquid and separated according to their chemical and physical properties. A vacuum pump can be used to speed up this physical extraction process. All KNF pumps are chemical-resistant and have a high vapor compatibility. When choosing a vacuum pump for solid-phase extraction, it is important to select a pump with both an appropriate flow rate and a vacuum level suited to the application. The N 816.3 KT.18 diaphragm vacuum...
Open the catalog to page 10Viscosity and container volume All KNF pumps are chemical-resistant and have a high vapor compatibility. The viscosity of the solvent and the container volume or capacity play an important role in both dessication and vacuum degassing. Viscous liquids such as gels, creams and synthetic resins require a higher ultimate vacuum than thin liquids. The larger the volume, the higher the flow rate required to ensure a fast evacuation of the system. Solvent Low viscosity fluid Diaphragm Vacuum Pump Solvent Viscous fluid Solvent Low viscosity fluid DESICCATION/ DEGASSING Flow rate: 16 l/min Ultimate vacuum:...
Open the catalog to page 11Diaphragm Vacuum Pump LABOPORT® N 820 G Volume £ 20 liters ■ Flow rate: 20 l/min ■ Ultimate vacuum: 6 mbar abs. ■ Adjustable motor speed control Diaphragm Vacuum Pump N 920 G Volume £ 20 liters Diaphragm Vacuum Pump LABOPORT® N 938.50 KT.18 Low viscosity fluid Volume > 20 liters Diaphragm Vacuum Pump LABOPORT® N 840 G Volume > 20 liters ■ Flow rate: 21 l/min ■ Ultimate vacuum: 2 mbar abs. ■ Adjustable motor speed control ■ Flow rate: 30 l/min ■ Ultimate vacuum: 15 mbar abs. ■ Optional fine control valve (suction side) available ■ Flow rate: 34 l/min ■ Ultimate vacuum: 6 mbar abs. ■ Adjustable...
Open the catalog to page 1216 Pages
12 Pages
24 Pages
16 Pages
16 Pages