Introduction
Sonos Pulse and Nexus Pulse fire beacons are designed to enhance fire evacuation through sound and light signals, addressing limitations of audible alarms for individuals with hearing impairments or in noisy environments.
Evacuation Technology
Klaxon Signals highlights the importance of visual alarm devices (VADs) in fire evacuation systems, as required by the EN54-23 standard, which ensures effective evacuation signals.
Pulse Alert Technology
This technology uses advanced LED systems for efficient light distribution, derived from automotive applications, to enhance light output and reduce power consumption, allowing more devices on a single system.
Applications
Suitable for environments like factories and hotels, Pulse Alert Technology ensures clear evacuation signals even in high-noise areas.
EN54-23 Fire Beacon Standard
Klaxon Signals exceeds EN54-23 requirements, offering devices with maximum coverage and minimal power consumption, categorized into Wall, Ceiling, and Open classifications.
Device Classifications
Ceiling-mounted devices provide cylindrical light coverage, while wall-mounted devices offer rectangular prism coverage, with Pulse Alert Technology exceeding requirements for both.
Energy Efficiency
Designed to be energy-efficient, Pulse Alert Technology reduces installation costs and allows easy upgrades without compromising performance.
Conclusion
Klaxon Signals' Pulse Alert Technology advances fire evacuation systems with powerful, energy-efficient visual alarm signaling, ensuring compliance with EN54-23.
Product Overview
The Nexus Pulse 110 is a high output sounder beacon with EN54-23 approved coverage, suitable for a 7.64m x 7.64m room when mounted up to 2.7m high.
Key Features
  • Conforms to EN54-23, exceeding illumination requirements.
  • Efficient power consumption with Pulse Alert Technology.
  • 7.64m coverage volume reduces device needs.
  • Easy installation with Wire to Base Technology.
  • Synchronized flash protects individuals with photosensitive epilepsy.
  • No surge current, eliminating startup power surges.
  • Weatherproof to IP66, suitable for various conditions.
Best Practice Guide to EN54-23
This guide emphasizes system design and installation compliance with EN54-23, considering ambient light levels, surface reflectivity, and environmental conditions.
General Rules for VAD Selection and Siting
  • Wall-mounted VADs are effective in high ambient light areas.
  • Ceiling-mounted VADs suit large open areas.
  • VADs should be visible to all occupants or illuminate adjacent surfaces.
  • Consider ambient light levels and use a light meter for accuracy.
  • Ensure VADs are the same color and not confused with other signals.
  • Synchronize multiple VADs visible from a single point.
Power Supplies
Both normal and standby power supplies should support the maximum alarm load independently, considering high peak current loads from VADs.
Additional Information
Klaxon’s Sonos and Nexus Pulse VADs offer extensive coverage, reducing the number of devices and cabling required, with minimal current draw.
See more

Catalog excerpts

Pulse Alert Technology Brochure-1

Evacuate everyone Sonos Pulse & Nexus Pulse EN54-23 Fire Beacons In a fire, everyone matters. Sonos Pulse and Nexus Pulse fire beacons ensure that all personnel are notified of fire emergencies. With Pulse Alert Technology, buildings are evacuated quicker, evacuation requirements are unambiguous and everyone is made to feel safe and secure. Signalling Solutions

 Open the catalog to page 1
Pulse Alert Technology Brochure-2

Evacuate Everyone Klaxon Signals believe that all fire alarm systems should be able to evacuate everyone – systems past, present and future. Relying on audible fire alarm notification alone disadvantages people with hearing impairments or those working, or living, in sound reducing conditions. Even something as simple as wearing a pair of headphones could prevent someone from hearing an audible fire evacuation warning. To truly evacuate everyone from a building, we need to signal effectively using light as well as sound. New European fire system standards recognise and legislate for these new...

 Open the catalog to page 2
Pulse Alert Technology Brochure-3

prjf.ce Alert ^^^^^^^^^^HP^^^^ The result is Klaxon's new Pulse Alert™ Technology. ^^^^|HP^^^^ This new beacon warning system produces a light output W^" "' that can protect most rooms with just a single device. New optical systems disperse light evenly, ensuring the most efficient distribution of light to maximise effectiveness. Our new LED lighting technology is derived from automotive applications, with a proven pedigree of reliability and performance in the harshest of environments. Advanced electronic design maximises electrical efficiency, reducing current consumption to minimise the cost...

 Open the catalog to page 3
Pulse Alert Technology Brochure-4

Applications Meeting the challenge of evacuating buildings using visual signalling, and exceeding the requirements of EN54-23, requires a step-change in beacon performance. Imagine the light output required for a single beacon to notify a person in a hotel room, or a factory worker in a machine room. When active, Sonos Pulse and Nexus Pulse fire alarm beacons are unmissable and unmistakable; attracting attention from people who are not looking at the device and already preoccupied with other tasks.

 Open the catalog to page 4
Pulse Alert Technology Brochure-5

Hotel Room Pulse Alert Technology produces a light output so bright it can notify someone in a hotel room, without relying on audible signalling. With up to 15m diameter coverage pattern for ceiling mount devices, and up to 11.3m coverage pattern for wall mount devices, even the largest hotel room can be protected with a single device. Gymnasium Visual Alarm Devices are not just for the hearing impaired. Even something as innocuous as wearing headphones provides challenges to evacuation systems. Klaxon’s sounder beacons, with Pulse Alert Technology, ensure that everyone is notified of a fire...

 Open the catalog to page 5
Pulse Alert Technology Brochure-6

EN54-23 Fire Beacon Standard EN54-23 Fire Beacon Standard At Klaxon Signals, we view regulatory compliance as a minimum requirement for any of our products. We strive to provide the ultimate in fire evacuation devices and invest in the latest technologies, the most talented people and manufacturing excellence to achieve this goal, every day. Our customers expect Klaxon products to exceed international standards and Pulse Alert Technology is no exception. Pulse Alert Technology is compliant with EN54-23, the European Standard for Visual Alarm Devices (VADs). This standard specifies the minimum...

 Open the catalog to page 6
Pulse Alert Technology Brochure-7

Categories EN54-23 specifies three different classification categories for Visual Alarm Devices: Wall, Ceiling and Open. Wall and Ceiling mount categories are specified at designated mounting heights and particular coverage pattern areas, as detailed by EN54-23. Open classification allows the manufacturer to specify the coverage volume and coverage shape, and does not restrict mounting height. Pulse Alert Technology has been designed to exceed the requirements of both Wall and Ceiling classifications, providing system designers with simple device performance specifications. Wall Classification...

 Open the catalog to page 7
Pulse Alert Technology Brochure-8

Pulse Alert Technology Seeing is Believing Klaxon Signals are experts in fire evacuation signalling, and are trusted by customers the world over to provide the latest technological advancements in fire safety. Using light to evacuate more people, quicker, safer and easier, without compromising on system performance or reliability, simply was not possible with previous evacuation technologies. To achieve our desired levels of product performance required something new, something different, something innovative. The result? Pulse Alert Technology – simply the most powerful and energy efficient...

 Open the catalog to page 8
Pulse Alert Technology Brochure-9

• Available in white & red flash versions • EN54-23 compliant beacon technology • Wall and ceiling mount light orientations • Wide coverage pattern - one device can protect most rooms • Energy efficient, low current consumption • Available in Sonos Pulse and Nexus Pulse VADs

 Open the catalog to page 9
Pulse Alert Technology Brochure-10

Increased Coverage Increased Coverage The simpler an evacuation system is, the more effective it is likely to be. Sonos Pulse and Nexus Pulse visual alarm devices are designed to fulfil evacuation requirements with just a single device for most rooms. Ceiling mounted devices are rated up to 15m diameter coverage; wall mount devices can cover up to 11.3m x 11.3m square room. System design requirements are therefore made easier, evacuation messages are clearer and more people are protected than ever before. Pulse Alert Technology Increases Device and System Coverage: • Up to 15m diameter ceiling...

 Open the catalog to page 10
Pulse Alert Technology Brochure-11

Pulse Alert Technology Coverage With up to 15m diameter coverage and up to 11.3m x 11.3m square coverage for ceiling and wall mounted versions respectively, Pulse Alert Technology can cover most rooms with a single device. This increased coverage allows fire systems to use the minimum number of devices and therefore maximise the performance of the system. This is particularly useful for upgrading existing systems as it avoids the need to add additional devices. Fewer devices also reduces the total power consumption, allowing the system to be powered directly from the fire control panel and avoiding...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.