Position Recognition
9Pages

{{requestButtons}}

Catalog excerpts

Position Recognition - 1

Position Detector 3.2 WIDENT/P for 8 positions (NC contact) Position detector for detection of eight different codes with eight outputs (NC contact). 3.3 WIDENT/P for 15 positions (Binary code) Position detector for detection of 15 different codes with four binary coded position outputs and one strobe output (NO contact). Other versions of the WIDENT/P position detector on request. 3.4 Application example with 8 positions Conventional roller shutter control: Limit switches, which are operated by cams attached to the moving part of the machine, are frequently used for easy position detection of linear or rotary movements in machines and systems. In this case it is only possible for the machine control system to assign the limit switch signal definitely to the position if a separate limit switch is used for each position. Roller shutter Rolltor door By using transponder-based WIDENT/P sensors, which e.g. in safety engineering are known as non-contact SIDENT safety switches, it is possible to detect several different positions with only one sensor. A further advantage in this case is insensitivity to dirt, maladjustment and manipulation and the avoidance of components susceptible to wear. Transponder-based actuating elements are attached to the moving part of the machine instead of the operating cams with the result that the WIDENT/P, which is mounted on the stationary machine part, can detect the actuating elements and read their intrinsic information as they move past. A specific code is assigned to each of the actuating elements so that the WIDENT/P’s position detector can detect which actuating element is currently within its reading range based on the code. An associated output switching signal which can be processed in the machine control system is generated in the WIDENT/P in line with the information read out. Innovative roller shutter control: Code “1” Code “2” Code “3” This principle can also be used, for example, to control a roller shutter as shown in the diagram above. Actuating Betätigungselements elemente All the electronics of this position detector are accommodated in a sensor housing. Connection is made by a 12-pin connector. There are four green and two yellow LED’s as position indicators. A further green LED serves as a status indicator. Roller Rolltor shutter door 3.1 WIDENT/P for 8 positions (NO contact) Position detector for detection of eight different codes with eight outputs (NO contact). Note: The mounting instructions and terms of use in the device description must be observed when using the WIDENT/P. © Klaschka Industrieelektronik GmbH • Am Zeller Pfad 1 • D-75242 Neuhausen • Fon +49 7234 79 0 • Fax 79 112

Open the catalog to page 1
Position Recognition - 2

Position Detector -► switches withcode"1" Comparatorfor positionsignals -► switches withcode"4" -► switches withcode"5" -► switches withcode"6" 4. Response range The following values are applicable for parallel and central alignment of the sensing faces of sensor and actuating element. If the sensing faces are inclined towards each other, this results in deviations from the values mentioned by around ± 10 % at an angle of inclination up to 30°. Response range in the longitudinal and lateral axis SIDENT/B-22fv20-5O1 SIDENT/B11fs14-401 Deviation X from the reference position (sensor centre)...

Open the catalog to page 2
Position Recognition - 3

WIDENT/P Ref. no. 13.28-07 Response range in the longitudinal axis SIDENT/B-40fq100-401 Deviation Y from the reference position (sensor centre) in mm KLASCHKA © Klaschka Industrieelektronik GmbH • Am Zeller Pfad 1 • D-75242 Neuhausen • Fon +49 7234 79 0 • Fax 79 112 • e-mail: sales@klaschka.de • www.klaschka.de

Open the catalog to page 3
Position Recognition - 4

Position Detector 5. Technical data _Type_ Ref. no. Positions Switching distance, hysteresis Assured switching-off distance Design Housing material Installation specification Connection Max. permissible lead length Ambient temperature range Protection rating, weight Protective insulation O Cannot be installed flush Cannot be installed flush Cannot be installed flush typ. UL+ - 1.75 V (100 mA) < 400 mA per output max. 800 mA in total typically 10 ms typ. 200 ms Operating voltage range UL Current consumption Operating mode Output voltage Output current Response time Drop-off time (pulse...

Open the catalog to page 4
Position Recognition - 5

WIDENT/P Ref. no. 13.28-07 Table: Connector pin and lead assignment Design Housing material Installation specification Protection rating, weight Protective insulation H Do not install flush; attach preferably with one-way screws or glue in Do not install flush; attach preferably with one-way screws or glue in to prevent manipulation Identification Structure Ambient temperature range © Klaschka Industrieelektronik GmbH • Am Zeller Pfad 1 • D-75242 Neuhausen • Fon +49 7234 79 0 • Fax 79 112 • e-mail: sales@klaschka.de • www.klaschka.de

Open the catalog to page 5
Position Recognition - 6

Installation example: Position Detector Metal-free area (bilateral) Note: Other versions of the actuating elements available on request. Position detection Actuating element Ref. no. Position 1 Position 2 Position 3 Position 4 Position 5 Position 6 Position 7 Position 8 Housing material Installation specification Metal parts sideways of or behind the actuating element are permissible, but may affect the operating range. Protection rating, weight Protective insulation Ambient temperature range © Klaschka Industrieelektronik GmbH • Am Zeller Pfad 1 • D-75242 Neuhausen • Fon +49 7234 79 0 •...

Open the catalog to page 6
Position Recognition - 7

WIDENT/P Ref. no. 13.28-07 _Type_ Ref. no. Housing material Protection rating Protective insulation B Connector pin diagram / Insulated core colours Cross-section Description Ambient temperature range Connection 12 x 0.5 mm2 LIYY, flexible, PVC grey - 30 ... + 70 °C Type Ref. no. Housing material Protection rating Protective insulation O Ambient temperature range Connection Socket, 12-pole, crimp contact © Klaschka Industrieelektronik GmbH • Am Zeller Pfad 1 • D-75242 Neuhausen • Fon +49 7234 79 0 • Fax 79 112 • e-mail: sales@klaschka.de • www.klaschka.de

Open the catalog to page 7