video corpo

Cables For force, torque and strain sensors
13Pages

{{requestButtons}}

Catalog excerpts

Cables For force, torque and strain sensors - 1

Cables For force, torque and strain sensors Charge mode, high impedance piezoelectric measurement demands highly insulated coaxial cables and connectors to ensure an insulation resistance greater than 1013 Ω throughout the measuring chain. Only low noise coaxial cables that produce very little triboelectricity during movement may be used. The connectors must be robust, sealed and resistant to dirt. Low noise cable with extruded Teflon sheath O-ring seals against cable O-ring seals against sensor connector Kistler connectors have been developed specifically to meet these requirements and are made of stainless steel. Unlike galvanized connectors they are therefore not subject to any wear, and measurement reliability and accuracy are improved. All Kistler connectors contain an O-ring seal at the cable end and the connection end. Most Kistler sensors have a connection with a KIAG 10-32 or M4 male thread. Connectors with a swivel nut and versions with an integral thread are available for both variants. The one-piece body of the connectors with an integral thread can be welded to the sensor in order to ensure that, for example when the sensor is firmly mounted, the screw connection cannot work loose. For the connection of connectors with an integral thread, cable and sensor must be able to rotate freely in relation to each other. The selection chart shown on page 2 specifies the type numbers of the most commonly used connecting cables for force, torque and strain sensors. The individual types with available lengths are described on the following pages. The details of multiconductor and special application connecting cables may be found on the corresponding sensor data sheets. The abbreviation pos. stands for male and neg. for female connectors. Stainless steel swivel nut Gold-plated center spring made of Beryllium copper Built-in strain relief (no heat shrinkable sleeving necessary) Fig. 1: Connector with swivel nut Low noise cable with extruded Teflon sheath O-ring seals against sensor connector O-ring seals against cable Built-in strain relief (no heat shrinkable sleeving necessary) Integral thread in body of connector Gold-plated center spring made of Beryllium copper Fig. 2: Connector with integral thread Page 1/13 This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. © 1994 ... 2022 Kistler Group, Eulachstraße 22, 8408 Winterthur, Switzerland Tel. +41 52 224 11 11, info@kistler.com, www.kistler.com. Kistler Group products are protected by various intellectual property rights. For more details visit www.kistler.com

Open the catalog to page 1
Cables For force, torque and strain sensors - 2

Cables – For force, torque and strain sensors Selection chart for connecting cables M4x0,35 pos. M4x0,35 pos. int. KIAG 10-32 pos. with pull-out thread M5 Selection chart for extension cables Page 2/13 This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. © 1994 ... 2022 Kistler Group, Eulachstraße 22, 8408 Winterthur, Switzerland Tel. +41 52 224 11 11, info@kistler.com, www.kistler.com. Kistler Group products are protected by various...

Open the catalog to page 2
Cables For force, torque and strain sensors - 3

Cables - For force, torque and strain sensors <ISTLERmeasure, analyze, innovate.Type 1601B... Connecting cable BNC Length (m) Temperature range Smallest possible bending radius Cable plug BNC pos. Cable PVC BNC pos. Degree of protection (EN60529) IP40 black 03,2 mm IP40 Type 1603B... Extension cable BNC Length (m) Temperature range Smallest possible bending radius Cable plug BNC neg. Cable PVC BNC pos. Degree of protection (EN60529) IP40 black 03,2 mm IP40 Type 1609B... Connecting cable for sensors with TNC neg. connector Length (m) 2/5/10/20/50/sp (Lmin = 0,1 m/Lmax = 50 m) Temperature...

Open the catalog to page 3
Cables For force, torque and strain sensors - 4

Cables – For force, torque and strain sensors Connecting cable TNC armored Length (m) 5/sp (Lmin = 1 m/Lmax = 10 m) Temperature range –25 … 70°C Smallest possible 5 mm bending radius Cable plug Degree of protection (EN60529) Type 1619B… Cable PVC black TNC pos. with flexible stainless steel hose ø9,7 mm IP65 Connecting cable armored for sensors with TNC neg. connector Length (m) 5/10/sp (Lmin = 1 m/Lmax = 20 m) Temperature range –25 … 70°C Smallest possible 5 mm bending radius Cable plug Degree of protection (EN60529) Type 1631C… TNC pos. Cable PVC black IP65 with flexible stainless steel...

Open the catalog to page 4
Cables For force, torque and strain sensors - 5

Cables – For force, torque and strain sensors Connecting cable for sensors with KIAG 10-32 neg. connector Length (m) 0,5/1/2/5/10/sp (Lmin = 0,1 m/Lmax = 15 m) Temperature range –55 … 200°C Smallest possible 5 mm bending radius Cable plug Degree of protection (EN60529) Type 1637C… KIAG 10-32 pos. Cable PFA green ø2 mm IP65 Extension cable KIAG 10-32 Length (m) 5/sp (Lmin = 0,3 m/Lmax = 5 m) Temperature range –55 … 200°C Smallest possible 5 mm bending radius Cable plug Degree of protection (EN60529) Type 1641B… KIAG 10-32 neg. Cable PFA green ø2 mm IP65 Connecting cable for sensors with KIAG...

Open the catalog to page 5
Cables For force, torque and strain sensors - 6

Cables - For force, torque and strain sensors <ISTLERmeasure, analyze, innovate.Type 1651C... Connecting cable for sensors with M4x0,35 neg. connector Length (m) Temperature range Smallest possible bending radius Cable plug M4x0,35 pos. Cable PFA green 0 2 mm Length (m) Temperature range Smallest possible bending radius Cable plug M4x0,35 pos. Cable PFA green 02 mm KIAG 10-32 pos. Length (m) Temperature range Smallest possible bending radius Cable PFA green 02 mm KIAG 10-32 pos. int. Connecting cable for sensors with M4x0,35 neg. connector 1631C_000-346e-01.22 Length (m) 0,8/sp (Lmin — 0,1...

Open the catalog to page 6
Cables For force, torque and strain sensors - 7

Cables - For force, torque and strain sensors <ISTLERmeasure, analyze, innovate.Type 1937A... Connecting and test cable, mini coax Length (m) Temperature range Smallest possible bending radius is Cable plug Mini-Coax pos. Cable PFA green 02 mm BNC pos. Type 1939A... Connecting cable for sensors with KIAG 10-32 neg. connector Length (m) Temperature range Smallest possible bending radius Cable plug KIAG 10-32 pos. int. Cable PFA green 02 mm BNC pos. Type 1941A... Length (m) Temperature ra Smallest possibl bending radius Cable plug Degree of protection (EN60529) Type 1943A... Connecting cable...

Open the catalog to page 7

All Kistler catalogs and technical brochures

  1. Torque sensors

    40 Pages

  2. Force sensors

    42 Pages