HKIPP&A zoiueixi - an OTT HydroMet brand - CUV5 and SUV Series Ultraviolet Radiometers Operational Manual
Open the catalog to page 1OTT HydroMet B.V. Delftechpark 36 2628 XH Delft The Netherlands +31 15 2755 210 [email protected] www.otthydromet.com All rights reserved. All content is the intellectual property of OTT HydroMet. Reprinting, duplication and translation (even as excerpts) are only permitted with the prior written consent of OTT HydroMet. Subject to technical change.
Open the catalog to page 22 Order numbers and variant code_ 6 2.2 Accessories and spare parts_ 6 3 About this manual_ 8 3.1 Other applicable documents_ 8 3.2 General signs and symbols_ 8 4 General safety instructions_ 9 4.5 Danger of burns due to hot surfaces_ 9 6 Transport, storage, and unpacking_ 13 7.1.2 Required tools and aids_ 14 7.1.3 Installation for measurement on a horizontal plane_ 14 7.2.1 Electrical connections of CUV5 radiometer_ 16 7.2.2 Electrical connections of SUV radiometers_ 16 7.2.4 Analog voltage output_ 18
Open the catalog to page 38.1.1 Starting the Smart Explorer Software_ 20 8.1.3 Adjusting the communication parameters_ 22 8.1.4 Finding an instrument with unknown communication parameters_ 24 9.1 Making and saving measurements_ 25 13 Notes on disposing of old devices_ 29 14.1 Optical and electrical data_ 30 15.2 Instrument spectral response and ideal UV response_ 33 15.3 Indoor measurement with lamps_ 36 15.4 Directional response and its impact on UV measurement_ 36
Open the catalog to page 4The following items are included with the radiometers: - Calibration certificate - Instruction sheet - 2 stainless steel screws M5 x 80 mm - Nuts and flat washers - Nylon insulation ring
Open the catalog to page 5The following documents contain further information on installation, maintenance and calibration: - Smart Pyranometer Communication Manual - Smart Explorer Software Manual The signs and symbols used in the operating manual have the following meaning: i This symbol indicates important and useful information. ■/ Prerequisite that must be met before performing an action. o Intermediate result of an action o Result of a completed action - List item, 1st level - List item, 2nd level To avoid personal injury and material damage, you must observe the safety information and warnings in the operating...
Open the catalog to page 8The radiometer is used to measure and report the global ultraviolet (UV) solar irradiance. Any use of the product that does not comply with the intended use, be this intentional or negligent, is forbidden by the manufacturer. ► Use the product only as described in the operational manual. The equipment described in this manual must be installed, operated, maintained and repaired by qualified personnel only. ► Obtain training from OTT HydroMet if necessary. To avoid equipment damage and injury when handling the product, personnel are obliged to the following: ► Read the operational manual carefully...
Open the catalog to page 94.7 Certification CE (EU) The equipment meets the essential requirements of EMC Directive 2014/30/EU. FCC (US) FCC Part 15, Class "B" Limits This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. IC (CA) Canadian Radio Interference-Causing Equipment Regulation, ICES-003, "Class B" This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations....
Open the catalog to page 105 Product description 5.1 Design and function CUV5 and SUV radiometers are designed and calibrated to measure global ultraviolet (UV) solar irradiance. There are models for the specific UV bands and they provide measurements in units of W/m2: – CUV5 and SUV5 cover the total UV range. – SUV-A covers the UVA band. – SUV-B covers the UVB band. – SUV-E measures with the standard "Erythemal" response of human skin. The CUV5 radiometer has a low-level analog output signal directly from the detector. SUV radiometers feature internal digital signal processing and outputs for industrial data acquistion...
Open the catalog to page 118 Adjustable leveling feet 3 Glass or quartz dome 8 Adjustable leveling feet
Open the catalog to page 12► Carefully remove the product from the packaging. ► Check that the delivery is complete and undamaged. ► If you find any damage or if the delivery is incomplete, then immediately contact the supplier and manufacturer. ► Keep the original packaging for any further transportation. ► Store within specified temperature ranges. ► Store in original box where possible.
Open the catalog to page 13► Check the desiccant of the CUV5 radiometer and replace the desiccant if necessary. ► If using the digital output of the SUV radiometer, set the Modbus® address before visiting the site. Otherwise a computer and RS-485 / USB converter is required during installation. The following tools and aids are required: There should be no obstructions to the field of vision above the instrument's sensor element. If this is not possible, the location of the instrument must be chosen to ensure that obstacles do not rise by more than 5 degrees above the azimuth range between sunrise after the shortest night...
Open the catalog to page 142x flat washers 2x nuts 2 2x nylon insulating rings ► To insulate the instrument against the temperature of the mounting device, place the instrument on the adjustable foot and the two leveling feet. ► Position the instrument in such a way that the nuts are located at a distance of 2 to 3 mm from the mounting device. ► Ensure that the instrument is grounded. ► Ensure that the instrument is not in the shade. ► When installed horizontally, point the cable connector towards the nearest pole to reduce the UV exposure on the cable. ► In order to align the instrument horizontally, rotate the leveling...
Open the catalog to page 15Damage due to power supply! The instrument does not require power. Connecting power causes damage to the instrument. ► Do not connect the instrument to power supply. The CUV5 radiometer has a 2-wire cable and 2-pin connector. The maximum recommended cable length is 100 m of good quality shielded 2-core signal cable. Damage due to power or ground loops! Connecting the RS-485 to a grounded circuit and the analog output to a floating circuit can cause ground loops. This may cause differential voltages that will damage the instrument. ► Use either the analog or the digital output. ► Observe the maximum...
Open the catalog to page 164 Pages
20 Pages
8 Pages
2 Pages
2 Pages
4 Pages
4 Pages
4 Pages
2 Pages
4 Pages
2 Pages
8 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
4 Pages
2 Pages
16 Pages
2 Pages
24 Pages
1 Page
2 Pages
2 Pages
2 Pages
4 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
92 Pages
4 Pages
2 Pages
4 Pages
4 Pages
2 Pages
4 Pages
2 Pages
2 Pages
8 Pages
12 Pages
2 Pages
2 Pages
2 Pages