TOS5200 Hipot Tester
8Pages

{{requestButtons}}

Catalog excerpts

TOS5200 Hipot Tester - 1

An ideal AC Hipot Tester with low cost of ownership realized, built on more than 50 years of experience in market Hipot (Withstanding Voltage) Tester Highly-stable output with PWM Amp System 5 kV/100 mA (500 VA) AC Hipot test Short-circuit current 200 mA or more Rise time/Fall time control Equipped with RS232C and USB Interface

Open the catalog to page 1
TOS5200 Hipot Tester - 2

An ideal AC Hipot Tester with ownership realized, built on 50 years of experience ! Rise/Fall Time control function of the applied voltage Equipped with a Rise time/ Fall time control function Prevents from an excessive stress applied to the EUT or for standard tests. Highly stable output Newly developed, high-efficiency PWM switching amplifier ! Providing a stable output of high voltage without being affected by AC line variation. Ensure the user to perform highly reliable testing with confidence, even in regions with large voltage variations. (Input voltage fluctuation rate: ±0.3 %)...

Open the catalog to page 2
TOS5200 Hipot Tester - 3

low cost of more than High Precision High Resolution ± 1.5 % of reading* High-precision measurement ±1.5 % of reading *(with voltmeter 500 V or higher, Ammeter 1 mA or higher) More than 50 years of experience to support "JAPAN-quality" Our electronic safety tester has more than 50 years of history since the first product was released in 60's. Supporting the World-wide input voltage Universal usability ! Usable in any country without changing the input power supply. Selectable output frequency ! Not rely on the input power environment. It supplies the stable test voltage with 50/60 Hz...

Open the catalog to page 3
TOS5200 Hipot Tester - 4

The TOS5200 has many improvements from the predecessor ! lComparison with the Kikusui previous model TOS5200 Output method Specification comparison item Slide transformer method As per commercial power supply waveform Synchronized with commercial power supply waveform Output voltage waveform Commercial power supply waveform Voltage regulation Input voltage variation Minimum setting value ±(100 ppm + 20 ms) excluding Fall Time Upper limit setting Lower limit setting Rise Time and Fall Time control features Test time Test voltage Digital, analog Judgment feature Measurement accuracy...

Open the catalog to page 4
TOS5200 Hipot Tester - 5

Hipot (Withstanding Voltage)Tester VALUE! Capable of Test Time setting from 0.1s, which enables to reduce the tact time ! TOS5200 can set the test time from 0.1 sec without sacrificing measurement accuracy. This makes test time 5 times faster compared to the TOS5050A (max test time:0.5sec) and it leads to reduce the tact time. Reduction of the tact time leads to improve the productivity, so it has been an issue that reducing the tact time may cause to worsen the measurement accuracy when the test time is faster than measurement respond speed. Cycle time Rise time / Fall time control...

Open the catalog to page 5
TOS5200 Hipot Tester - 6

Unless specified otherwise, the specifications are for the following settings and conditions. • The warm-up time is 30 minutes. • TYP: These are typical values. These values do not guarantee the performance of the product. • rdng: Indicates the readout value. • set: Indicates a setting. • f.s: Indicates full scale. n Withstanding voltage tester Output range ± (2 % of set + 20 V) when no load is connected Operating range Max. rated current AC Output section 100 mA (when the output voltage is 0.5 kV or greater) Transformer rating Output voltage waveform *2 Distortion Crest factor If the...

Open the catalog to page 6
TOS5200 Hipot Tester - 7

Hipot (Withstanding Voltage)Tester *1. Regarding the output time limits: Taking size, weight, and cost into consideration, the heat dissipation capability of the voltage generator that is used for withstanding voltage tests has been designed to be one half that of the rated output. Use the TOS5300 Series within the following limits. If you use the product in a manner that exceeds these limits, the output section may overheat, and the internal protection circuits may be activated. If this happens, stop testing, and wait until the TOS5300 Series returns to its normal temperature. Ambient...

Open the catalog to page 7
TOS5200 Hipot Tester - 8

n Specifications n General Display LCD: LED back custom indicators Installation location Environ- Spec guaranteed range temperature/humidity ment Operating range temperature/humidity Storage range temperature/humidity Nominal voltage range (allowable voltage range) Power supply Power consumptio When no load is connected (READY) When rated load isconnected Allowable frequency range Insulation resistance (between AC LINE and the chassis) Withstanding voltage (between AC LINE and the chassis) Earth continuity Complies with the requirements of the following directive and standard. EMC Directive...

Open the catalog to page 8

All Kikusui Electronics catalogs and technical brochures

  1. TOS9300 Series

    28 Pages

  2. KHA Series

    16 Pages

  3. KFM2005

    4 Pages

  4. KFM2030

    4 Pages

  5. PFX2500 Series

    16 Pages

  6. PLZ6000R

    4 Pages

  7. TOS9213AS

    2 Pages

  8. PCR-LE2 Series

    28 Pages

  9. PWX series

    12 Pages

  10. PBZ Series

    20 Pages

Archived catalogs