PLZ6000R
4Pages

{{requestButtons}}

Catalog excerpts

PLZ6000R - 1

Regenerative DC Electronic Load Regenerative DC Electronic Load PLZ6000R No necessity of special cooling system such as water cooling method Voltage/current/power range: 30 V - 400 A / 60 V - 200 A / 6 kW Power regeneration efciency of up to 90% or more! Six load modes (CC/CR/CV/CP/CC+CV/CR+CV) Easy-to-use design featuring a large-size LCD panel Equipped with major interfaces (GPIB, RS-232C, and USB) as standard

Open the catalog to page 1
PLZ6000R - 2

Regenerative Electronic Load Environment-friendly DC electronic load of the power line regeneration type Capable of regenerating power with clean current waveforms Power regeneration efciency of up to 90% Large capacity 6kW Regenerative DC Electronic Load PLZ6000R is a DC electronic load that regenerates load power to the AC line. Regular electronic loads consume load power by having semiconductor devices convert it into heat. By contrast, PLZ6000R converts load power into reusable electric power, rather than converting it into heat as is typically done, and feeds this power to the AC line,...

Open the catalog to page 2
PLZ6000R - 3

Functions Power regeneration efficiency of up to 90% (at rated power) The use of a proprietary switching technology (patent pending) provides high power regeneration efficiency - from 85% or more at one-third of rated power (2000 W) to a maximum of 90% or more. This energy saving feature greatly reduces the electronic load's environment impact on your plant and it is not necessary to equip special cooling system such as water cooling method to supress the heat generation. Soft start function In constant current (CC) mode, this function causes the load current to rise gradually when the...

Open the catalog to page 3
PLZ6000R - 4

Specications Rating 30 V range 60 V range 30 V range 60 V range 10 mA ± (0.4% of set + 400 mA) 400 mA rms p-p Soft start Operation mode Selectable time range Time accuracy Operating range Setting range Resolution Setting accuracy Input voltage variation Ripple Constant Resistance (CR) mode 134 S to 2.5 mS (7.4627 mΩ to 400 Ω) 34S to 2.5 mS 60 V range (29.412 mΩ to 400 Ω) 136 S to 0 S 30 V range (7.3529 mΩ to OPEN) 34 S to 0 S 60 V range (29.412 mΩ to OPEN) ± (0.5% of set* + 2 A) *set = Vin/Rset 30 V range Operating range Setting range Setting accuracy 2 V for a single line (The sensing line...

Open the catalog to page 4

All Kikusui Electronics catalogs and technical brochures

  1. TOS9300 Series

    28 Pages

  2. KHA Series

    16 Pages

  3. KFM2005

    4 Pages

  4. KFM2030

    4 Pages

  5. PFX2500 Series

    16 Pages

  6. TOS9213AS

    2 Pages

  7. PCR-LE2 Series

    28 Pages

  8. PWX series

    12 Pages

  9. PBZ Series

    20 Pages

Archived catalogs