Catalog excerpts
of Broad range s output mode High-performance multifunctional AC Power Supplies Capable of various power line abnormality simulations and the sequence operation Single phase 500 VA to 9 kVA/Single phase & three–phase 6 kVA, 9 kVA, 27 kVA, Supporting the system for the single-phase, and expandable with optional drivers for the single-phase three-wire, and three–phase operation. Expandable capacity up to 27 kVA (single–phase), 54 kVA (single–phase three–line), and 81 kVA (three–phase) Features a full range of measuring functions and supports AC, DC, and AC + DC Outputs Detachable front panel Eco-friendly function equipped ) are available as an optional interface. RS-232C as a standard interface, and GPIB, USB, and LAN (
Open the catalog to page 1being smart Solar power Wind power Fuel cell
Open the catalog to page 2PCR-LE series
Open the catalog to page 3New stage of AC power supply supporting new energy field High-performance AC Power Supplies PCR-LE SERIES The PCR-LE Series is a new line of advanced multifunctional AC power supply that has been developed from our PCR-L / L A Series (linear amplifier type). T he P CR-L E S er ies prov ides high r eliabili t y and can be applied to various applications, by taking advantage of the features that can control broadband waveform freely. Moreover, the PCR-LE Series can be configured as a core device of a test system combined with E-loads and Power Analyzers for “Grid Connection Testing” in regard...
Open the catalog to page 4PCR-LE series ● Lineup PCR1000LE Output capacity Single-phase 500VA Single-phase 1kVA Maximum output current DC mode L/H range Dimensions (mm(inches)) (Maximum dimensions) Weight
Open the catalog to page 5Reliability Inspection Production Inspection Satisfy Safety Service QA The linear amplifier type realizes high stability and high quality output and supports a wide range of functions from R&D to manufacturing/inspection lines and servicing. What is a linear amplifier type? Firstly, the input power is converted to DC power by a rectifier circuit, then it supplies the power as the linear amplifier. A sine wave reference voltage is created by such a crystal oscillator, and it is used as input into the linear amplifier, where the power amplification is performed to generate the output power....
Open the catalog to page 6PCR-LE series ■ For Adjustment and Inspection lines: ● Evaluation for the immunity of power abnormalities. Capable of DC output. ● ● Easily conducting power measurement. ● Can be used in anechoic chambers and shield rooms. ● To confirm the power voltage margin. ● Use in automated inspection systems. The PCR-LE Series has equipped with the measurement functions built into the main unit, it can be used not only for voltage and current measurement, but also for convenient measurement of apparent and effective power, inrush (peak) current, power factor, highfrequency current, and other values....
Open the catalog to page 7features ■ Extended system for large capacity. Flexible configuration in models. It is possible to expand to 27 kVA (single phase), 54 kVA (single phase 3-wire), and 81 kVA (three phase) by using the parallel, single phase 3-wire, and three phase operation options (expansion operation drivers). This allows the system to be used for large-scale EMC site power or as test power for large-capacity industrial air conditioners. ■ Parallel operation *The separately-sold expansion operation driver is required. 2 kVA or higher model / Max. connectable units: 5 / Max. expansion capacity: Single phase...
Open the catalog to page 8PCR-LE series ■ Wide-ranging specs DC output also supported ■ Eco-friendly function (Power-conservation function) ■ Sleep function The power unit goes into the sleep mode when no output is detected for a specified period to save the power consumption. ■ Energy-saving operation function* You can utilize the energy-saving function to operate only the number of power unit(s) depending on the required supply load. [Example] Operation with a 4 kVA model when 1 kVA is necessary Output voltage rating (AC) Output frequency rating Output voltage rating (DC) ln addition, the system supports a DC...
Open the catalog to page 9performance ● Example of single phase 3-wire system configuration Capacity Single-phase three-wire driver ● Example of PCR2000LE parallel operation system configuration Capacity Parallel operation driver (Master) Parallel operation driver (Slave) 【Example of single phase 3-wire 4 kVA system】 【Example of parallel operation 4 kVA system】 Connecting cable Accessories 75cm Connecting cable Accessories 75cm Power-sync cable Power signal cable ● Example of PCR9000LE parallel operation system configuration Parallel operation driver (Master) Parallel operation driver (Slave) ● Example of...
Open the catalog to page 10PCR-LE series ● Example of parallel operation Three-phase operation system configuration Capacity Three-phase output driver Parallel operation driver (Master) Parallel operation driver (Slave) Three-phase output driver Parallel operation driver (Master) Parallel operation driver (Slave) Extension connection cable CC02-PCR-LE 2.8m Extension connection cable CC02-PCR-LE 2.8m Accessories for three-phase driver and parallel operation driver Power signal cable 0.3m Power-sync cable Accessories 1m *equivalent to the LC01-PCR-LE Connecting cable 0.7m ● Example of the combined system using...
Open the catalog to page 11applications ■ For testing of the Smart Grid related applications ● Power conditioner DUT Applied to reverse load flow! Simulated power supply for solar panels Load switch (route switch) Power supply voltage for detector circuit tests Line impedance network Fixed resistors Power meter Simulated AC load Simulated system AC power supply Communication interface LAN, USB, RS-232C, GPIB ● Storage Battery for Residential use DUT Storage Battery for residential use DUT Battey power conditioner Fixed resistors Line impedance network Power meter Simulated system AC power supply Communication...
Open the catalog to page 12PCR-LE series ■ For testing of the Smart Grid related applications ● Smart meter DUT Indoor Regenerative simulated AC power supply Applied to reverse load flow! Simulated system AC power supply Line impedance network Simulated load Power meter *Single-phase 3-wire driver Requires the 2P05-PCR-LE Communication interface LAN, USB, RS-232C, GPIB ● For testing of the Heat pump DUT Heat pump unit Compressor section Input fluctuation test Load variation test Drive test Electronic Load Use as a simulated load for a power conditioner grid connection test system. ● Maximum input load power: 1000W ●...
Open the catalog to page 13All Kikusui Electronics catalogs and technical brochures
-
TOS9300 Series
28 Pages
-
Warning Light / Buzzer
52 Pages
-
Calibration Equipments
52 Pages
-
KHA Series
16 Pages
-
KFM2005
4 Pages
-
KFM2030
4 Pages
-
KFM2150 System
8 Pages
-
PFX2500 Series
16 Pages
-
PFX2000 Series
8 Pages
-
PFX2000 Series Basic Package
4 Pages
-
PFX2400 Series
8 Pages
-
TOS6200A Ground Bond Tester
52 Pages
-
TOS5200 Hipot Tester
8 Pages
-
PLZ6000R
4 Pages
-
TOS9213AS
2 Pages
-
PWX series
12 Pages
-
PBZ Series
20 Pages
Archived catalogs
-
Electrical Safety Tester
40 Pages