Overview: The KHA Series Harmonic/Flicker Analyzer is designed for compliance testing of single-phase and three-phase equipment, adhering to standards such as IEC61000-3-2, IEC61000-3-3, IEC61000-3-11, and IEC61000-3-12. It supports equipment with current ratings up to 75A per phase, with models like the KHA3000 accommodating higher currents.
Specifications: The analyzer complies with IEC and JIS standards for harmonic and flicker testing, supporting both old and new measurement techniques. The KHA3000 model can handle measurements beyond 40A per phase with firmware updates and additional sensors.
Features: The KHA Series offers real-time display and analysis, functioning as both an oscilloscope and FFT analyzer. It provides real-time compliance judgments and can generate test reports without a PC. Integration with AC power supplies and line impedance networks is possible for comprehensive testing setups.
Operation: The operation flow includes setting test conditions, starting tests, analyzing results, and printing reports. The device supports easy upgrades to accommodate new standards and allows users to switch between old and new standards in real-time.
Measurement Capabilities: The KHA Series measures harmonic compliance for currents between 16A and 75A per phase and flicker compliance for voltage fluctuations. It provides detailed graphical and list displays of various parameters, including V/I waveforms, harmonic trends, and flicker values.
Additional Functions: The analyzer includes a quality check function for power supplies, supports repeatability checks, and allows for simultaneous three-phase measurements. It features user-friendly interfaces and terminals, with support for GPIB, RS232C, and USB connections.
Technical Specifications: The KHA Series supports a maximum input voltage of 600Vrms and current up to 40Arms. It offers various measurement functions, including voltage, current, power, and frequency, with high accuracy and resolution. The device is equipped with a rush current measurement capability and provides guidance on standards and technical terms through an assist function.
Measurement Functions: The device can analyze voltage harmonics up to the 40th order and includes flicker/voltage fluctuation analysis conforming to IEC standards.
Standards and Requirements: The device adheres to IEC 61000-3-3 and IEC 61000-3-11 standards for flicker analysis, and IEC 61000-4-15 for measuring instrument standards. It provides Pst accuracy of 1 ± 5% with measurement times ranging from 30 to 900 seconds.
General Measurement Functions: Includes current/voltage waveform monitoring, FFT analysis, and in-rush current measurement. Communication interfaces supported are GPIB, RS232C, and USB.
Data Storage and Control: Data can be stored on Compact Flash memory cards up to 512 MB or USB memory up to 16 GB. External equipment control is possible via PCR-LA control using RS232C.
Environmental Conditions: The device operates within a temperature range of 0℃ to 40℃ and humidity of 20%rh to 80%rh. It has a withstanding voltage of 1500VAC for AC input to chassis and 3550VAC for measuring terminal to chassis.
Safety and EMC: Complies with the Low Voltage Directive 2006/95/EC and EMC instruction 89/336/EEC. Accessories include a power cord, voltage sensing terminal plug, and operation manual.
Software Applications: The KHA3000 and KHA1000 models come with dedicated software for harmonic analysis, allowing test condition settings, execution, and data analysis. The software supports Windows operating systems and requires specific system configurations.
AC Power and Impedance Network: Specifications for the PCR-LA series AC power units and LIN40MA-PCR-L impedance network include output capacity, frequency range, and impedance values.
Accessories and Options: Various accessories are available, including multi-outlet units, rack mount brackets, and Ethernet ports. The OP02-KHAS device is used for daily checks of harmonic and flicker measurement systems.
Procedures: Setup procedures emphasize using appropriate wiring to minimize voltage drop and ensure accurate measurements, recommending thick cables (at least 8mm2) for connections exceeding 16A.
Calibration and Traceability: Calibration is conducted in compliance with ISO/IEC17025 standards, although KIKUSUI does not directly provide ISO/IEC17025 compliant calibration for the KHA1000/3000. Calibration data can be provided with an expression of uncertainty as a chargeable option.
Recommendations: For accurate harmonics measurement, it is advised to use the internal shunt resistor and clamp sensors, with a relative error margin of ±0.6%. Enabling Delta Transform for KHA3000 version 2.00 or higher is suggested.
Additional Information: The document includes contact information for distributors and notes on product specifications, which are subject to change. It also highlights the importance of using the equipment under qualified supervision.
See more

Catalog excerpts

KHA Series-1

Harmonic / Flicker Analyzer Harmonic/Flicker Analyzer Supports harmonic and flicker compliance testing of single-phase and three-phase equipment IEC61000-3-2 Ed3.0/A2 (Harmonics for 16A or less) IEC61000-3-3 Ed2.0, Ed1.2 (Flicker for 16A or less) IEC61000-3-11 (Flicker for over 16A)* IEC61000-3-12 (Harmonics for 75A or less)* IEC61000-4-7 Ed2.0/A1, Ed2.0, Ed1.0 (Interharmonics ON/OFF) *Only Model KHA3000

 Open the catalog to page 1
KHA Series-2

Harmonic /Flicker Analyzer Harmonic and flicker analyzer compliant with the latest versions of the IEC and JIS standards The KHA series is a Harmonic/Flicker Analyzer that complies to the standard of IEC /EN and JIS. The KHA1000 is dedicated for the single-phase equipment with two wires, and the KHA3000 applies to the test exceeding 16A of the single-phase and three-phase equipment (up to 40A per phase). Furthermore, the KHA series is compliant with both existing and the latest version of measurement technique standards, so you can simply select the measurements of the latest version of standard...

 Open the catalog to page 2
KHA Series-3

Characteristics and Features *Only Model KHA3000 ◆ Applying to the single phase and the three-phases* (40A/phase) 16A/phase or less*1 IEC61000-3-2, -3-3 Single phase KHA1000 dedicated for single phase (16A or less). *1: The JIS specifies 20A/ phase or less. *2: For measurement of 40A or more phase current, an optional device (external current sensor) is required. ◆ Conducting compliance testing without using a PC Using this device alone, you can perform a series of test processes - from setting test conditions and running the test to judging test results against limit values and outputting result...

 Open the catalog to page 3
KHA Series-4

Measurement of harmonic compliance test (16A to 75A/phase) *omy Model KHASOOC Measured values Rsce values that clear the limit values on the real-time monitor. circuit ratio(Rsce) value Sequ[Vfl] Ssc[W] L^Te ■ft iii g"~ oT "a "E^an 3a rd —Fes^ Rated Current (Iequ) | Measured 1 Tobs : Quasi-Stat Nominal SLJS Volt(V) Nominal Frequency Measurement Time(s) Ref Fund Curr II | Measi Judgement Rsce Meas Technic lYou can set test conditions while monitoring the measured values. within R (33), the minimum short- circuit ratio (Rsce) value that clears short-circuit ratio (Rsce) values from its the short-circuit...

 Open the catalog to page 4
KHA Series-5

◆Real-time display & measurement that gives you a quick grasp of the EUT status   ● List of view types Harmonic current test Flicker/voltage fluctuation test Graph display ● V/I waveforms ● 2D harmonics ● 3D harmonics ● THC ● Current trend ● Harmonic current trend ● Vector phases *Only Model KHA3000 ● V/I waveforms ● rms waveform ● St (short time flicker value) waveform ● CPF (cumulative probability) curve ● dc waveform ● dmax waveform ● d (t) > 3.3% waveform List display ● List (real-time measured values) ● Harmonic list ● Result list ● Flicker list ● Result list ● d measurement (manual switch)...

 Open the catalog to page 5
KHA Series-6

◆Allows changes in the test conditions while monitoring VIEW key You can change the test conditions with the monitor screen unchanged. ◆Capable of simultaneous measurement of the three-phases The long-time flicker value in all segment time, “Plt” is specified to be 2 hours for the flicker monitoring period. For three-phase equipment, measurement can be taken for each phase, but that will take 2 hours x 3 = 6 hours. Simultaneous measurement of three-phases can shorten the measuring (testing) time to 2 hours. Impedance network Equipment under test (EUT) U ◆ In order to fully cover the EUT input...

 Open the catalog to page 6
KHA Series-7

◆Providing all major basic measurements ◆Rush current measurement KHA Series are capable of measuring all major basic items including voltage, current, power, power factor, apparent power, reactive power and frequency. I t a l s o p r ov i d e s o t h e r measurement functions such as waveform monitoring and measurements of rush current and harmonic current in low frequency zones. T h e s e fe a t u r e s m a ke KHA Series a convenient routine work tool for development and design processes. KHA Series obser ves the waveform of the rush current exceeding the trigger level. It can also o b s e...

 Open the catalog to page 7
KHA Series-8

Maximum input current 40Arms / 100Apeak, whichever is smaller 160Apeak (within 20 ms) Number of input channels 3 channels for both voltage input and current input (L1, L2 and L3) 1 channels for both voltage input and current input Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire and three-phase 4-wire Rated voltage for the range Voltage measurement function Voltage measurement input switching Common input specifications Maximum input voltage Allowable crest factor Display item Rated current for the range Current measurement function Allowable crest factor Accuracy *1 Power measurement...

 Open the catalog to page 8
KHA Series-9

Options Application software [SD006-KHA] Harmonics Analyzing Suite Ver 2.2 ◆ KHA1000 Application software [SD005-KHA] Harmonics Explorer Ver 3.5 ◆ KHA3000 This dedicated application software consists of 3 programs. Using this software, you can set test conditions and control the execution of tests. You can also control the AC power supply (PCR-LA) used for tests. Furthermore, you can print the harmonic spectrum, and current and voltage waveforms on your reports. ■Program configuration of SD006-KHA Harmonics Analyzing Suite and SD005-KHA Harmonics Explorer SD006-KHA Offers functions to set conditions...

 Open the catalog to page 9
KHA Series-10

i HA File Analyzer 3 / HA File Analyzer HA File Analyzer 3 / HA File Analyzer are application programs that allows you to analyze the data in the test result files (xxx. hr3 / xxx.hr) saved by HarmoCapture 3 / HarmoCapture. It is not necessary to connect with KHA Series to run, so, you can analyze test data anywhere you want. ■Screen configuration Lists the result files of harmonic current tests. Displays graphs of the harmonic current test result file. AScreen configuration (HA File Analyzer 3) AScreen configuration (HA File Analyzer) ■ Repeatability of check results HA File Analyzer displays...

 Open the catalog to page 10
KHA Series-11

● VF File Analyzer 3 / VF File Analyzer VF File Analyzer 3 / VF File Analyzer are application programs that allows you to analyze the data in the test result files (xxx. vr3 / xxx.vr) saved by HarmoCapture 3 / HarmoCapture. It is not necessary to connect with KHA Series to run, so, you can analyze test data anywhere you want. ■Printing test result file reports You can generate and print reports of the test result files saved by KHA3000 or HarmoCapture 3 in PDF format. ■Screen configuration Waveform over entire measuring time Result/setting data list Display the waveforms of voltage fluctuations...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.