Catalog excerpts
Harmonic / Flicker Analyzer Harmonic/Flicker Analyzer Supports harmonic and flicker compliance testing of single-phase and three-phase equipment IEC61000-3-2 Ed3.0/A2 (Harmonics for 16A or less) IEC61000-3-3 Ed2.0, Ed1.2 (Flicker for 16A or less) IEC61000-3-11 (Flicker for over 16A)* IEC61000-3-12 (Harmonics for 75A or less)* IEC61000-4-7 Ed2.0/A1, Ed2.0, Ed1.0 (Interharmonics ON/OFF) *Only Model KHA3000
Open the catalog to page 1Harmonic /Flicker Analyzer Harmonic and flicker analyzer compliant with the latest versions of the IEC and JIS standards The KHA series is a Harmonic/Flicker Analyzer that complies to the standard of IEC /EN and JIS. The KHA1000 is dedicated for the single-phase equipment with two wires, and the KHA3000 applies to the test exceeding 16A of the single-phase and three-phase equipment (up to 40A per phase). Furthermore, the KHA series is compliant with both existing and the latest version of measurement technique standards, so you can simply select the measurements of the latest version of...
Open the catalog to page 2Characteristics and Features *Only Model KHA3000 ◆ Applying to the single phase and the three-phases* (40A/phase) 16A/phase or less*1 IEC61000-3-2, -3-3 Single phase KHA1000 dedicated for single phase (16A or less). *1: The JIS specifies 20A/ phase or less. *2: For measurement of 40A or more phase current, an optional device (external current sensor) is required. ◆ Conducting compliance testing without using a PC Using this device alone, you can perform a series of test processes - from setting test conditions and running the test to judging test results against limit values and outputting...
Open the catalog to page 3Measurement of harmonic compliance test (16A to 75A/phase) *omy Model KHASOOC Measured values Rsce values that clear the limit values on the real-time monitor. circuit ratio(Rsce) value Sequ[Vfl] Ssc[W] L^Te ■ft iii g"~ oT "a "E^an 3a rd —Fes^ Rated Current (Iequ) | Measured 1 Tobs : Quasi-Stat Nominal SLJS Volt(V) Nominal Frequency Measurement Time(s) Ref Fund Curr II | Measi Judgement Rsce Meas Technic lYou can set test conditions while monitoring the measured values. within R (33), the minimum short- circuit ratio (Rsce) value that clears short-circuit ratio (Rsce) values from its the...
Open the catalog to page 4◆Real-time display & measurement that gives you a quick grasp of the EUT status ● List of view types Harmonic current test Flicker/voltage fluctuation test Graph display ● V/I waveforms ● 2D harmonics ● 3D harmonics ● THC ● Current trend ● Harmonic current trend ● Vector phases *Only Model KHA3000 ● V/I waveforms ● rms waveform ● St (short time flicker value) waveform ● CPF (cumulative probability) curve ● dc waveform ● dmax waveform ● d (t) > 3.3% waveform List display ● List (real-time measured values) ● Harmonic list ● Result list ● Flicker list ● Result list ● d measurement (manual...
Open the catalog to page 5◆Allows changes in the test conditions while monitoring VIEW key You can change the test conditions with the monitor screen unchanged. ◆Capable of simultaneous measurement of the three-phases The long-time flicker value in all segment time, “Plt” is specified to be 2 hours for the flicker monitoring period. For three-phase equipment, measurement can be taken for each phase, but that will take 2 hours x 3 = 6 hours. Simultaneous measurement of three-phases can shorten the measuring (testing) time to 2 hours. Impedance network Equipment under test (EUT) U ◆ In order to fully cover the EUT...
Open the catalog to page 6◆Providing all major basic measurements ◆Rush current measurement KHA Series are capable of measuring all major basic items including voltage, current, power, power factor, apparent power, reactive power and frequency. I t a l s o p r ov i d e s o t h e r measurement functions such as waveform monitoring and measurements of rush current and harmonic current in low frequency zones. T h e s e fe a t u r e s m a ke KHA Series a convenient routine work tool for development and design processes. KHA Series obser ves the waveform of the rush current exceeding the trigger level. It can also o b s...
Open the catalog to page 7Maximum input current 40Arms / 100Apeak, whichever is smaller 160Apeak (within 20 ms) Number of input channels 3 channels for both voltage input and current input (L1, L2 and L3) 1 channels for both voltage input and current input Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire and three-phase 4-wire Rated voltage for the range Voltage measurement function Voltage measurement input switching Common input specifications Maximum input voltage Allowable crest factor Display item Rated current for the range Current measurement function Allowable crest factor Accuracy *1 Power...
Open the catalog to page 8Options Application software [SD006-KHA] Harmonics Analyzing Suite Ver 2.2 ◆ KHA1000 Application software [SD005-KHA] Harmonics Explorer Ver 3.5 ◆ KHA3000 This dedicated application software consists of 3 programs. Using this software, you can set test conditions and control the execution of tests. You can also control the AC power supply (PCR-LA) used for tests. Furthermore, you can print the harmonic spectrum, and current and voltage waveforms on your reports. ■Program configuration of SD006-KHA Harmonics Analyzing Suite and SD005-KHA Harmonics Explorer SD006-KHA Offers functions to set...
Open the catalog to page 9i HA File Analyzer 3 / HA File Analyzer HA File Analyzer 3 / HA File Analyzer are application programs that allows you to analyze the data in the test result files (xxx. hr3 / xxx.hr) saved by HarmoCapture 3 / HarmoCapture. It is not necessary to connect with KHA Series to run, so, you can analyze test data anywhere you want. ■Screen configuration Lists the result files of harmonic current tests. Displays graphs of the harmonic current test result file. AScreen configuration (HA File Analyzer 3) AScreen configuration (HA File Analyzer) ■ Repeatability of check results HA File Analyzer...
Open the catalog to page 10● VF File Analyzer 3 / VF File Analyzer VF File Analyzer 3 / VF File Analyzer are application programs that allows you to analyze the data in the test result files (xxx. vr3 / xxx.vr) saved by HarmoCapture 3 / HarmoCapture. It is not necessary to connect with KHA Series to run, so, you can analyze test data anywhere you want. ■Printing test result file reports You can generate and print reports of the test result files saved by KHA3000 or HarmoCapture 3 in PDF format. ■Screen configuration Waveform over entire measuring time Result/setting data list Display the waveforms of voltage...
Open the catalog to page 11All Kikusui Electronics catalogs and technical brochures
-
TOS9300 Series
28 Pages
-
Warning Light / Buzzer
52 Pages
-
Calibration Equipments
52 Pages
-
KFM2005
4 Pages
-
KFM2030
4 Pages
-
KFM2150 System
8 Pages
-
PFX2500 Series
16 Pages
-
PFX2000 Series
8 Pages
-
PFX2000 Series Basic Package
4 Pages
-
PFX2400 Series
8 Pages
-
TOS6200A Ground Bond Tester
52 Pages
-
TOS5200 Hipot Tester
8 Pages
-
PLZ6000R
4 Pages
-
TOS9213AS
2 Pages
-
PCR-LE2 Series
28 Pages
-
PWX series
12 Pages
-
PBZ Series
20 Pages
Archived catalogs
-
Electrical Safety Tester
40 Pages