kieback peter Technology for Building Automation
Open the catalog to page 1The DDC4000 automation system Provides unlimited possibilities The world of building automation is changing. The future has already begun with the DDC4000 automation system. Secure and reliable operation starts with people The DDC4200 automation station offers users a new operating concept. With its customized “close-up” operating concept the DDC4200 provides optimum comfort and high levels of security. All menus on the color TFT touch screen are individually configured with intuitive user assistance. The installation status is visible at a glance. 2 Control and optimization tasks can be...
Open the catalog to page 2Code necessary for changing set points Current flow set point 77°C ESC Plants Outputs Values Times Pic University - heating Utilization time DDC4000- ventilation control center Trend: dampers securely integrated into the system. All automation stations can be operated remotely via a web browser from any location, turning every PC into an operating console. Additional colored touch screen displays can also be integrated. The automation stations can also be operated interdependently Object oriented modules offer individual solutions The supplied software provides the DDC4000 system with...
Open the catalog to page 3DDC4000 components Automation stations The DDC4000 automation system is a completely new development. It includes the international BACnet and LON communication standards and offers solutions for different installation types and sizes. Software menus for adaptation of the operating and control functions are an integral part of each automation station. The DDC4200 automation station is the key to a new operating philosophy for fast and secure plant operation. A color TFT screen guides users through all system components. The DDC4200 Automation station with TFT touch screen and plain text...
Open the catalog to page 4DDC4000 components The BMD, BMA input/output bus modules The bus compatible I/O modules of the DDC4000 system are used wherever a large number of physical data points come together at a single location. The modules include a service cabinet connection and offer Plug&Play comfort. added, the modules can be cascaded without additional cabling. Modules can also be replaced without the need for new cabling. The modules register themselves as soon as they are activated. Secured in stable plastic housings, they are ready for DIN rail mounting. If a large number of data points are to be A very...
Open the catalog to page 5Practical applications Solutions for buildings and properties of every kind Steigenberger Hotel de Saxe, Dresden, Germany The Hotel de Saxe next to the Dresden Women’s Church has 185 bedrooms, 7 conference rooms, a restaurant, bar and fitness room. Nine DDC4200 automation stations monitor and control the heating, ventilation and air conditioning, water heating and smoke extraction. The automation stations communicate via an Ethernet network. The LON based technolon® system is utilized for room automation. The Neutrino-GLT building management system works on the management level. This also...
Open the catalog to page 8The siid.stadt.bad is Nuremberg's largest indoor swimming pool and is made up of a combination of sport and leisure pools. The DDC4000 building automation system monitors and controls the heating, ventilation and air conditioning as well as the complex swimming pool technology. A set of controllers control the ventilation technology and two other sets control the heating. The three swimming pool tech- nology circuits are each amalgamated automation station is installed in all sets of controllers. The automation stations communicate with the Neutrino-GLT building management system via...
Open the catalog to page 9DDC4000 on site From small solutions to unlimited possibilities Single boiler plant Single boiler plant with by-pass control Static Heating Static heating with two heating circuits 10
Open the catalog to page 10Spray humidifier Pre-heater i Cooler Re-heater Supply air fan Ventilation System Room ventilation technology with heater, cooler, humidifier - control of temperature and air humidity Fixed value control Plant for filling level control or room temperature control - fixed value control with switchable setpoint, PI control, Y Set, Y Min andY Max functions if required
Open the catalog to page 11Technical data Automation stations DDC4200, DDC4002, DDC4200-L, DDC4400 Autonomous automation stations for control, optimization, operation and monitoring functions. Processor, memory, operating system Motorola 32 bit processor with integrated Ethernet controller Internal 256 MB compact flash, 96 MB RAM Embedded Linux operating system for stable use Physical interfaces Binary inputs and outputs, individually switchable, of which 8 impulse inputs of 80 Hz Analog inputs and outputs, individually switchable (only DDC4200, DDC4400) Active inputs: 0..10 V DC or KP10 Passive inputs: Pt100,...
Open the catalog to page 12Communication The future already today The DDC4000 automation system creates new potential. The Linux operating system and the integrated web server constitute the platform for all current and future demands. Remote control of the network The DDC4000 automation station offers all possibilities for using web services, such as using larger, individual displays. The automation stations can be conveniently integrated into new and existing networks via the Ethernet interface. Remote access makes the user flexible and mobile. The interactive user interface of the DDC4000 automation station is...
Open the catalog to page 13Overview of the DDC4000 Binary inputs or outputs Analog inputs or outputs 32 24 32 – 32 24 - - Bus compatible input/output module (Bus Module Analog) for concentrating a large number of physical data points at a single location – 24 Bus compatible input/output module (Bus Module Digital) for concentrating a large number of physical data points at a single location 32 – Bus compatible input/output module (Bus Module Digital) for concentrating a large number of physical data points at a single location 64 – Functions Automation stations DDC4200 DDC4002 Automation station with TFT touch screen...
Open the catalog to page 14All Kieback & Peter catalogs and technical brochures
-
DDC4000 automation system
4 Pages
-
MD15 Small Actuator
8 Pages
-
Actuators and control valves
12 Pages
-
MF200 Emergency Actuator
38 Pages
-
MF201 Emergency Actuator
26 Pages
-
HRP22-V
6 Pages
-
BMR410 Controller
10 Pages
-
HRP Heating Control Processor
16 Pages
-
Stellantriebe und Stellventile
60 Pages
-
DDC3000 Automation System
34 Pages
-
DDC4000 Automation System
26 Pages
-
LON Room Automation, Wireless
18 Pages
-
Transducers
24 Pages