N9038A MXE EMI Receiver
22Pages

{{requestButtons}}

Catalog excerpts

N9038A MXE EMI Receiver - 1

Data Sheet This data sheet is a summary of the specifications and conditions for the MXE EMI receiver. For the complete specifications guide, visit: Anticipate_Accelerate_Achieve Or Agilent Technologies

Open the catalog to page 1
N9038A MXE EMI Receiver - 2

Keep the test queue flowing In EMC testing, success depends on tools that can help you do more in less time—today and tomorrow. That’s why Agilent created the MXE: it’s a standards-compliant EMI receiver and diagnostic signal analyzer built on an upgradeable platform. In the lab and on the bench, it provides the accuracy, repeatability, and reliability you need to test with confidence. Equip your team with the MXE, and keep the test queue flowing.

Open the catalog to page 2
N9038A MXE EMI Receiver - 3

Definitions and Conditions Specifications describe the performance of parameters covered by the product warranty and apply to the full temperature range of 0 to 55 °C, unless otherwise noted. 95th percentile values indicate the breadth of the population (approx. 2 σ) of performance tolerances expected to be met in 95 percent of the cases with a 95 percent confidence, for any ambient temperature in the range of 20 to 30 °C. In addition to the statistical observations of a sample of instruments, these values include the effects of the uncertainties of external calibration references. These...

Open the catalog to page 3
N9038A MXE EMI Receiver - 4

Frequency and Time Specifications Frequency range Input 1 Option 508 Option 526 Option 544 Frequency reference Accuracy ± [(time since last adjustment x aging rate) + temperature stability + calibration accuracy] Total aging Temperature stability 20 to 30 °C Full temperature range Achievable initial calibration accuracy Example frequency reference accuracy 1 year after last adjustment Frequency readout accuracy (start, stop, center, marker) ± (marker frequency x frequency reference accuracy + 0.25 % x span + 5 % x RBW + 2 Hz + 0.5 x horizontal resolution 1) Marker frequency counter Accuracy...

Open the catalog to page 4
N9038A MXE EMI Receiver - 5

Sweep time and triggering Range Span ≥ 10 Hz, swept Span ≥ 10 Hz, FFT Span = 0 Hz ± 0.01 % (nominal) ± 40 % (nominal) ± 0.01 % (nominal) Free run, line, video, external 1, external 2, RF burst, periodic timer Trigger delay Span = 0 Hz or FFT Span ≥ 10 Hz, swept Resolution Time gating Gate methods Gated LO; gated video; gated FFT Gate length range (except method = FFT) Gate delay range Gate delay jitter Sweep (trace) point range All spans Resolution bandwidth (RBW) EMI bandwidths (CISPR compliant) Bandwidth accuracy (power) ± 1.0 % (± 0.044 dB) ± 2.0 % (± 0.088 dB) ± 0.07 dB (nominal) ± 0.15...

Open the catalog to page 5
N9038A MXE EMI Receiver - 6

Analysis bandwidth 1 Maximum bandwidth Video bandwidth (VBW) Range 1 Hz to 3 MHz (10 % steps, E24 series 24 per decade), 4, 5, 6, 8 MHz, and wide open (labeled 50 MHz) Measurement speed Local measurement and display update rate Remote measurement and LAN transfer rate Marker peak search Center frequency tune and transfer (RF) Center frequency tune and transfer (μW) Measurement/mode switching Time domain sweep times CISPR band B, 150 kHz to 30 MHz, RBW = 9 kHz, measurement time = 100 ms, peak detector CISPR band B, 150 kHz to 30 MHz, RBW = 9 kHz, measurement time = 1 s, quasi-peak detector...

Open the catalog to page 6
N9038A MXE EMI Receiver - 7

Amplitude Accuracy and Range Specifications Amplitude range Measurement range Displayed average noise level (DANL) to maximum safe input level Input attenuator range Maximum safe input level (with and without preamp) RF Input 1 Average total power Peak pulse power < 10 μs pulse width, < 1 % duty cycle and input attenuation ≥ 30 dB Surge power DC volts DC coupled AC coupled Display range Log scale 0.1 to 1 dB/division in 0.1 dB steps 1 to 20 dB/division in 1 dB steps (10 display divisions) Linear scale Scale units dBm, dBmV, dBμV, dBmA, dBμA, V, W, A dBuV/m, dBuA/m, dBpT, dBG, dBpW Frequency...

Open the catalog to page 7
N9038A MXE EMI Receiver - 8

Frequency response (continued) Option 508 or 526 (RF/μW) Preselector on, preamp off Preselector on, preamp on (0 dB attenuation) 1. DC coupling required to meet specifications below 50 MHz. With AC coupling, specifications apply at frequencies of 50 MHz and higher. Statistical observations at 10 MHz with AC coupling show that most instruments meet the DC-coupled specifications, however, a small percentage of instruments are expected to have errors exceeding 0.5 dB at 10 MHz at the temperature extreme. The effect at 20 to 50 MHz is negligible but not warranted. Input attenuation switching...

Open the catalog to page 8
N9038A MXE EMI Receiver - 9

Input voltage standing wave ratio (VSWR) Preselector off, preamp on and off DC coupled Resolution bandwidth switching uncertainty (referenced to 30 kHz RBW) 1 Hz to 1.5 MHz RBW Reference level Range Log scale Linear scale Display scale switching uncertainty Switching between linear and log Display scale fidelity Between –10 dBm and –80 dBm input mixer level ± 0.10 dB total Total measurement uncertainty 1 Signal level 0 to 90 dB below reference point, RF attenuation 0 to 40 dB, RBW ≤ 3 MHz, 20º to 30º C: AC coupled 10 MHz to 26.5 GHz DC coupled 9 kHz to 40 GHz Option 508 or 526 (RF/μW) 1....

Open the catalog to page 9
N9038A MXE EMI Receiver - 10

Total measurement uncertainty 1 (continued) Trace detectors Normal, peak, sample, negative peak, log power average, RMS average, and voltage average CISPR detectors: quasi-peak, EMI-avg, RMS-avg Preamplifier Gain +20 dB (nominal) +35 dB (nominal) +40 dB (nominal) +20 dB (nominal) +35 dB (nominal) +40 dB (nominal) Amplitude probability distribution Dynamic range Amplitude accuracy Maximum measureable time period (no dead time) Minimum measureable probability Amplitude level assignment Sampling rate Amplitude resolution

Open the catalog to page 10
N9038A MXE EMI Receiver - 11

Dynamic Range Specifications 1 dB gain compression Specification Typical Maximum power at mixer Frequency range Option 508 or Option 544 526 (RF/μW) (mmW) RF Input 1 to 44 GHz (RF Input 2 to 1 GHz, performance = RF Input 1 performance + 9 dB) Preselector on and off, 9 kHz to 10 MHz preamp off 10 to 500 MHz 0 dBm 500 MHz to 3.6 GHz +1 dBm 3.6 to 26.5 GHz 0 dBm 26.4 to 44 GHz Preselector off, preamp on 10 MHz to 3.6 GHz 3.6 to 26.5 GHz Tone spacing 100 kHz to 20 MHz Tone spacing > 70 MHz 26.4 to 44 GHz 9 kHz to 10 MHz 10 to 2 GHz 2 GHz to 3.6 GHz 3.6 to 26.5 GHz Tone spacing, 100 kHz to 20...