N5241A PNA-X Microwave Network Analyzer
117Pages

{{requestButtons}}

Catalog excerpts

N5241A PNA-X Microwave Network Analyzer - 1

Agilent 2-Port and 4-Port PNA-X Network Analyzer N5241A - 10 MHz to 13.5 GHz N5242A - 10 MHz to 26.5 GHz Data Sheet and Technical Specifications

Open the catalog to page 1
N5241A PNA-X Microwave Network Analyzer - 2

Documentation Warranty THE MATERIAL CONTAINED IN THIS DOCUMENT IS PROVIDED "AS IS," AND IS SUBJECT TO BEING CHANGED, WITHOUT NOTICE, IN FUTURE EDITIONS. FURTHER, TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, AGILENT DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED WITH REGARD TO THIS MANUAL AND ANY INFORMATION CONTAINED HEREIN, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. AGILENT SHALL NOT BE LIABLE FOR ERRORS OR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, USE, OR PERFORMANCE OF THIS...

Open the catalog to page 2
N5241A PNA-X Microwave Network Analyzer - 6

This is a complete list of the technical specifications for the N5241A and N5242A network analyzer with the following options: Option 029, adds hardware and firmware for high-accuracy noise figure measurements, utilizing source correction techniques. It requires one of the following options: 219, 224, 419, or 423. It also requires an N4691B ECal module for use as an impedance tuner, and a 346-series noise source for calibration. See the block diagram. Option 200, 2-port standard test set (includes six front-panel access loops) and power range. See the block diagram. Option 219, adds 2-port...

Open the catalog to page 6
N5241A PNA-X Microwave Network Analyzer - 7

Corrected System Performance The specifications in this section apply for measurements made with the N5241A and N5242A analyzer with the following conditions: • 10 Hz IF bandwidth • No averaging applied to data • Isolation calibration with an averaging factor of 8 Table 1a. System Dynamic Range at Test Port 1 Option 200 or 400 Description Specification (dB) at Test Port Typical (dB) at Test Port Port 1 or 32 Port 2 or 42 Port 1 or 32 Port 2 or 42 10 MHz to 50 MHz3 93 93 106 104 50 MHz to 100 MHz3 103 103 116 115 100 MHz to 500 MHz3 117 117 131 130 500 MHz to 3.2 GHz 124 127 130 135 3.2 GHz...

Open the catalog to page 7
N5241A PNA-X Microwave Network Analyzer - 8

Table 1b. System Dynamic Range at Test Port 1 Option 219 or 419 Description Specification (dB) at Test Port Typical (dB) at Test Port Port 1 or 32 Port 2 or 42 Port 1 or 32 Port 2 or 42 10 MHz to 50 MHz3 93 93 106 104 50 MHz to 100 MHz3 103 103 115 114 100 MHz to 500 MHz3 117 117 130 129 500 MHz to 3.2 GHz 124 127 130 135 3.2 GHz to 10 GHz 127 127 135 134 10 GHz to 13.5 GHz 126 125 132 131 13.5 GHz to 16 GHz 126 125 132 131 16 GHz to 20 GHz 124 122 130 127 20 GHz to 24 GHz 118 117 127 124 24 GHz to 26.5 GHz 110 106 121 117 1 The system dynamic range is calculated as the difference between...

Open the catalog to page 8
N5241A PNA-X Microwave Network Analyzer - 9

Table 1c. System Dynamic Range at Test Port 1 Option 224 Description Specification (dB) at Test Port Typical (dB) at Test Port Source 2, Out 1 Source 2, Out 2 Source 2, Out 1 Source 2, Out 2 10 MHz to 50 MHz2 98 93 108 105 50 MHz to 100 MHz2 108 107 117 116 100 MHz to 500 MHz2 122 121 132 131 500 MHz to 3.2 GHz 128 128 134 136 3.2 GHz to 10 GHz 132 132 139 139 10 GHz to 13.5 GHz 130 130 138 137 13.5 GHz to 16 GHz 130 130 138 137 16 GHz to 20 GHz 129 127 136 134 20 GHz to 24 GHz 123 122 133 132 24 GHz to 26.5 GHz 114 112 127 124 1 The system dynamic range is calculated as the difference...

Open the catalog to page 9
N5241A PNA-X Microwave Network Analyzer - 10

Table 1d. System Dynamic Range at Test Port 1 Option 224 or 423 Description Specification (dB) at Test Port Typical (dB) at Test Port Port 1 or 32 Port 2 or 42 Port 1 or 32 Port 2 or 42 Source 1, Port 1 Combine Mode Source 2, Port 1 Combine Mode 10 MHz to 50 MHz3 93 93 106 104 104 80 50 MHz to 100 MHz3 103 103 115 115 112 90 100 MHz to 500 MHz3 117 117 130 130 121 99 500 MHz to 3.2 GHz 124 127 130 134 127 112 3.2 GHz to 10 GHz 127 127 136 134 132 119 10 GHz to 13.5 GHz 126 124 132 131 128 115 13.5 GHz to 16 GHz 126 124 132 131 128 115 16 GHz to 20 GHz 124 121 130 127 125 113 20 GHz to 24...

Open the catalog to page 10
N5241A PNA-X Microwave Network Analyzer - 11

Table 2a. Extended Dynamic Range at Direct Receiver Access Input1 Option 200 or 400 Description Typical (dB) at Direct Receiver Access Input Port 1 or 32 Port 2 or 42 10 MHz to 50 MHz3 128 128 50 MHz to 100 MHz3 115 115 100 MHz to 500MHz3 129 129 500 MHz to 3.2 GHz 136 139 3.2 GHz to 10 GHz 139 139 10 GHz to 13.5 GHz 139 139 13.5 GHz to 16 GHz 139 139 16 GHz to 20 GHz 139 136 20 GHz to 24 GHz 134 129 24 GHz to 26.5 GHz 124 121 1 The direct receiver access input extended dynamic range is calculated as the difference between the direct receiver access input noise floor and the source maximum...

Open the catalog to page 11
N5241A PNA-X Microwave Network Analyzer - 12

Table 2b. Extended Dynamic Range at Direct Receiver Access Input1 Option 219 or 419 Description Typical (dB) at Direct Receiver Access Input Port 1 or 32 Port 2 or 42 10 MHz to 50 MHz3 128 128 50 MHz to 100 MHz3 115 115 100 MHz to 500MHz3 129 129 500 MHz to 3.2 GHz 136 139 3.2 GHz to 10 GHz 139 139 10 GHz to 13.5 GHz 138 137 13.5 GHz to 16 GHz 138 137 16 GHz to 20 GHz 136 134 20 GHz to 24 GHz 130 129 24 GHz to 26.5 GHz 122 118 1 The direct receiver access input extended dynamic range is calculated as the difference between the direct receiver access input noise floor and the source maximum...

Open the catalog to page 12
N5241A PNA-X Microwave Network Analyzer - 13

Table 2c. Extended Dynamic Range at Direct Receiver Access Input1 Option 224 Description Typical (dB) at Direct Receiver Access Input Source 2, Out 1 Source 2, Out 2 10 MHz to 50 MHz2 133 128 50 MHz to 100 MHz2 120 119 100 MHz to 500MHz2 134 133 500 MHz to 3.2 GHz 140 140 3.2 GHz to 10 GHz 144 144 10 GHz to 13.5 GHz 142 142 13.5 GHz to 16 GHz 142 142 16 GHz to 20 GHz 141 139 20 GHz to 24 GHz 135 134 24 GHz to 26.5 GHz 126 124 1 The direct receiver access input extended dynamic range is calculated as the difference between the direct receiver access input noise floor and the source maximum...

Open the catalog to page 13
N5241A PNA-X Microwave Network Analyzer - 14

Table 2d. Extended Dynamic Range at Direct Receiver Access Input1 Option 224 or 423 Description Typical (dB) at Direct Receiver Access Input Port 1 or 32 Port 2 or 42 Source 1, Port 1 Combine Mode Source 2, Port 1 Combine Mode 10 MHz to 50 MHz3 128 128 139 115 50 MHz to 100 MHz3 115 115 124 102 100 MHz to 500MHz3 129 129 133 111 500 MHz to 3.2 GHz 136 139 139 124 3.2 GHz to 10 GHz 139 139 144 131 10 GHz to 13.5 GHz 138 136 140 127 13.5 GHz to 16 GHz 138 136 140 127 16 GHz to 20 GHz 136 133 137 125 20 GHz to 24 GHz 129 127 133 121 24 GHz to 26.5 GHz 119 121 127 114 1 The direct receiver...

Open the catalog to page 14