Catalog excerpts
AXIe Chassis •
Open the catalog to page 1I NT RO DU C T ION Pr od u c t d esc ri p t i o n The M9502A and M9505A AXIe chassis are fully compatible with the AXIe 1.0 specification. They provide 2 or 5 slots for AXIe instrument modules, and have an embedded system module that does not take up an instrument slot. The embedded system module (ESM) provides Gigabit LAN and Gen 2 x8 PCIe® interfaces for connecting the chassis to an external controller. To minimize rack space, the instrument module slots are arranged horizontally. In addition, the chassis are designed to be easily maintained. Both the power supply and fan tray can be...
Open the catalog to page 2The AXIe backplane in the Agilent M9502A and M9505A chassis include all of the following AXIe backplane lines: The M9502A and M9505A chassis are fully compliant with the AXIe 1.0 specification. In addition, the chassis complies with AdvancedTCA (ATCA) PICMG 3.0 R2.0 specifications, and is electrically compatible with standard ATCA modules. An additional half-height slot is built into the chassis and reserved for the embedded system module. This slot is not compatible with AXIe instrument modules or embedded computers. Embedded controllers must be installed in one of the instrument module...
Open the catalog to page 3Figure 2. M9505A backplane block diagram E mb e d d e d s y st e m m o d ul e ( ESM) In addition to the required functions, the system module also provides: Both the M9502A and M9505A chassis contain an embedded system module that does not take up an instrument slot. This module performs the chassis management functions contained in the AXIe specification, including: • Ability to synchronize multiple chassis with trigger and clocking signals (MultiFrame In/Out connectors) • Managing trigger and clock busses • SMA connectors for external clock in/out and trigger in/out • Managing clocks,...
Open the catalog to page 4The AXIe chassis utilize a cooling design that does not require additional rack space to cool the modules. This allows the chassis to fit into 2U or 4U of rack space. The M9502A and M9505A chassis come complete with IVI-COM, IVI-C, and LabVIEW drivers. Windows XP, Windows Vista, and Windows 7 operating systems are supported and applications can be completed using many different software tools including LabVEW, LabWindows/CVI, MATLAB, VEE, VisualStudio.NET (C/C++, C#, VB.NET). The cooling design uses auto-speed fans to pull in cool air. Air flows from right-to-left within the chassis. The...
Open the catalog to page 5TECHNICA L S P EC IFIC A T IO N S A N D C H A R A C T E R I S T I C S Chassis characteristics Standards compliance AXIe 1.0 Base Architecture specification AdvancedTCA PICMG 3.0 R2.0 specification Backplane M9502A Total slots Instrument module slots Input frequency range Input power consumption System module Power supply characteristics AC input Operating voltage range Overcurrent protection Efficiency (typical) DC supply Model Total DC module power Total max module current Load regulation Maximum ripple and noise (20 MHz BW) Chassis cooling and power dissipation Slot airflow direction...
Open the catalog to page 6TECH NICA L S P EC IFIC A T IO N S A N D C H A R A C T E R I S T I C S Clocks and triggers 100 MHz system clock (CLK100) Accuracy Duty cycle Maximum slot-to-slot skew External clock in (SMA) Input frequency Input level Minimum swing External clock out (SMA) Output frequency Output level Output load AXIe differential star trigger (STRIG) Maximum slot-to-slot skew External trigger out (SMA) Output level Output load External trigger in (SMA) Input level Input impedance Minimum swing Environmental characteristics 1, 2 Operating and storage conditions Operating Type tested at 95%, +40˚C...
Open the catalog to page 7TECHNICA L S P EC IFIC A T IO N S A N D C H A R A C T E R I S T I C S Regulatory characteristics Safety Complies with European Low Voltage Directive 2006/95/EC IEC/EN 61010-1, 2nd Edition Canada: CSA C22.2 No. 61010-1-04 USA: UL std no. 61010-1, 2nd Edition German Acoustic statement Acoustic noise emission LpA < 70 dB Operator position Normal position Per ISO 7779 Geraeuschemission LpA < 70 dB Am Arbeitsplatz Normaler Betrieb Nach DIN 45635 t.19 EMC Complies with European EMC Directive 2004/108/EC IEC/EN 61326-1 Canada: CSA C22.2 No. 61010-1-04 CISPR Pub 11 Group 1, Class A AS/NZS CISPR 11...
Open the catalog to page 8TECH NICA L S P EC IFIC A T IO N S A N D C H A R A C T E R I S T I C S ESM front panel connectors MultiFrame Clock Synchronizes timing signals with External clock connections In Out multiple daisy-chained chassis Input Output LAN Trigger USB (Option U20) Connects the host Connects a host to the External trigger PC to the chassis, via chassis via USB 2.0* connections 10/100/1000 Ethernet In Out PCIe Status light Connects a host PC to Chassis status the chassis via PCIe indicator light * USB port is only supported for a very limited set of Agilent AXIe modules. Check module documentation or...
Open the catalog to page 9d M9536A embedded AXIe controller Y1200B: x1 to x8 PCIe cables bles 2-slot AXIe chassis with embedded system module 5-slot AXIe chassis with embedded system module AXIe filler modules, getting started guide, drivers, and Agilent I/O libraries AXIe MultiFrame cable: 0.5m* AXIe MultiFrame cable: 3m* Desktop or rack mount PC N5650-00080 Single slot AXIe filler module *Check module documentation to see if MultiFrame cables are supported R ec om m en d e d c o n f i g u r a t i o n Configure the Agilent M9502A and M9505A AXIe chassis, as follows: 1. Configure the chassis connection to the host:...
Open the catalog to page 10AXIe chassis: 2-slot with embedded system module AXIe chassis: 5-slot with embedded system module Agilent Advantage Services is committed to your success throughout your equipment’s lifetime. Optional power cords Advantage services: Calibration and warranty 1. USB port is only supported for a very limited set of Agilent AXIe modules. Check module documentation or go to: www.agilent.com/find/axiechassisusb for compatibility information 3-year warranty (return to Agilent), standard 5-year return to Agilent warranty assurance plan 1. Options not available in all countries. Defin ition s f o r...
Open the catalog to page 11All KEYSIGHT TECHNOLOGIES catalogs and technical brochures
-
Network Visibility Products
24 Pages
-
RF Products
20 Pages
-
Basic Instruments
34 Pages
-
InfiniiVision 2000 X-Series
31 Pages
-
Signal Analyzers X-Series
21 Pages
-
KeysightCare
8 Pages
-
FieldFox and Nemo Handy
4 Pages
-
Impedance and Network Analysis
42 Pages
-
E4990A Impedance Analyzer
12 Pages
-
Keysight N6780 Series
10 Pages
-
E5071C ENA Network Analyzers
18 Pages
-
Keysight Process Analysis
7 Pages
-
BenchVue Software
2 Pages
-
Keysight Process Analysis
7 Pages
-
PXI RF Switch Modules
2 Pages
-
I/O Hardware
18 Pages
-
Digital Multimeters
28 Pages
-
Data Acquisition - DAQ
32 Pages
-
PCIe Digitizers
8 Pages
-
2015 Optical Component Test
40 Pages
-
Power Products Catalog
215 Pages
-
N9000A CXA Signal Analyzer
2 Pages
-
Agilent 89600 VSA Software
8 Pages
-
X-Series
23 Pages
-
CXA X-Series
8 Pages
-
SOLUTION BROCHURE
6 Pages
-
Waveguide Power Sensors
2 Pages
-
Power Meters and Power Sensors
34 Pages
-
E7515A UXM Wireless Test Set
2 Pages
-
E5063A Network Analyzer
8 Pages
-
N9320B RF Spectrum Analyzer
12 Pages
-
E5052B Signal Source Analyzer
21 Pages
-
N9038A MXE EMI Receiver
22 Pages
-
RDX Test Solutions for DigRF
17 Pages
-
M9252A DigRF Host Adapter
2 Pages
-
Oscilloscopes
16 Pages
-
Agilent Power Products
31 Pages
-
LIGHTWAVE CATALOG VOLUME I 2013
40 Pages
-
U4301A PCIe Analyzer
7 Pages
-
N9030A PXA Signal Analyzer
32 Pages
Archived catalogs
-
Agilent Technologies - Catalog
40 Pages