02 I Keysight M9485A PXIe Multiport Vector Network Analyzer - Brochure High-Performance PXI Multiport Vector Network Innovative solution Today's measurement requirements of components or modules used for wireless communication are getting more complicated based on growing technology and multi-carrier and multi-band coverage needs. The Keysight M9485A PXI multiport VNA is an ideal solution that provides flexible and scalable configuration, and solves your increasing challenges. Adapting independent source and receiver configuration, it offers the best measurement performance in multiport...
Open the catalog to page 2
03 | Keysight | M9485A PXIe Multiport Vector Network Analyzer - Brochure Fast speed The M9485A’s measurement speed increases throughput and decreases cost of test, especially in high-volume manufacturing, with best-in-class measurement speed in multiport network analysis. Figure 1. Fast measurement speed 1 Wide dynamic range 0 -20 -40 Wide dynamic range not only helps increase throughput of high rejection device test, but also improves test accuracy and yield. M9485A has up to 160 dB 2 dynamic range, best-in-class in PXI VNA, and comparable to the best bench-top VNAs. Figure 2. Wide dynamic...
Open the catalog to page 3
04 | Keysight | M9485A PXIe Multiport Vector Network Analyzer - Brochure Flexible Modular Multiport Configuration - 3 types of receivers to select from Standard (Option 1xx, 1 slot/port), Configurable test set (Option 2xx, slots/port) and direct receiver access (Option 3xx, 1 slot/port) - Up to 24 ports using two chassis (Option 1xx and 3xx) - Ability to mix different types of receivers in the same chassis - Easy to add / delete / change configuration for upgrade or repair 4 to 12 ports with one chassis 14 to 24 ports with two chassis Figure 4. 4-port configurable + 4-port standard Figure...
Open the catalog to page 4
05 | Keysight | M9485A PXIe Multiport Vector Network Analyzer - Brochure Multiport measurements The M9485A uses the latest Keysight VNA software platform. It helps you set and measure multiple traces easily channels and unlimited traces setups enable setting flexible multiport measurements. A guided calibration menu and copy channel feature enable full N-port calibrations and set stimulus conditions quickly. Figure 8. Measurement and setting display Flexible setting of multi-site You can set a single stimulus source for multiple test ports at the same time. This feature enables simultaneous...
Open the catalog to page 5
06 | Keysight | M9485A PXIe Multiport Vector Network Analyzer - Brochure Powerful Measurement Capability for a Variety of Applications The M9485A combines the highest RF performance with powerful analysis capabilities that enables you to address a variety of applications and increase test efficiency. Frequency offset mode, SMC and VMC for mixers The Scalar Mixer Calibration (SMC) provides the most accurate conversion loss/gain measurements. The Vector Mixer Calibration (VMC) is Keysight's VNA unique feature that enables you to measure the phase and group delay. External sources can be...
Open the catalog to page 6
07 | Keysight | M9485A PXIe Multiport Vector Network Analyzer - Brochure Basic RF Pulse Measurements The Basic RF pulse measurement option performs point-in-pulse and pulse profile measurements down to a pulse width on the order of 1 microsecond. Minimum resolution at pulse profile measurement is 70 nanoseconds. Four built-in pulse generators can be controlled by the Keysight VNA common user interface. By using the M9389A VNA source pulse modulator, the M9485A provides easy-to-use RF pulse measurement capability. Figure 14. Pulse profile measurement Gain Compression Analysis Characterizing...
Open the catalog to page 7
08 | Keysight | M9485A PXIe Multiport Vector Network Analyzer - Brochure Wide Dynamic Range and Fast Tuning for High Rejection Filters The configurable test set option M9485A-2xx occupies two modules for each test port: M9377A for direct access receiver and M9378A for coupler. This architecture offers the flexibility to set the signal path of the test port and bypass the loss caused by the coupler arm. Therefore the forward measurement receiver sensitivity and the dynamic range can be improved by 15 dB. Combined with segment sweep and the flexible electrical receiver attenuator, high...
Open the catalog to page 8
09 | Keysight | M9485A PXIe Multiport Vector Network Analyzer - Brochure Product Configuration Configurable test port Direct access receiver 1 slot/port Distributor module -1 slot Accessory kit (Cable, 2-way/4-way divider) Standard Receiver 1 slot/port M9037A High-performance embedded controller Test Port M9485A simplified block diagram example Ref In 100MHz 2 or 4- Way Divider External display (Software front panel) Apogee Source Modules M9301A * 100MHz M9301A * *: Modified M 9301A (optimized for fast sweep Configurable test set port Standard receiver port Figure 19. Simplified block...
Open the catalog to page 9
10 | Keysight | M9485A PXIe Multiport Vector Network Analyzer - Brochure Keysight PXIe VNA Comparison High-performance multiport True modular expands capabilities Flexible, scalable, and re-configurable Dynamic range, typ @10 Hz IFBW Trace noise, typ @10 kHz IFBW Multi-site test YES (with same stimulus, 1 for one system) YES (with independent stimulus, 1 for 2-port VNA) * N-port calibrated meas (551) (mandatory for > 4-port) * Time domain (010) * Frequency offset mode (009) * Basic RF pulse measurements (025) * Gain compression analysis (086) * N-port calibrated meas (551) (mandatory for >...
Open the catalog to page 10
11 | Keysight | M9485A PXIe Multiport Vector Network Analyzer - Brochure Ordering Information Hardware option M9485A-1xx X-port standard test set option. 1 MHz to 9 GHz. X is available as even number from 4-port (Option 104) to 24-port (Option 124) . 1 slot/port. X-port configurable test set option. 50 MHz to 9 GHz. X is available as even number from 2-port (Option 202) to 12-port (Option 212). 2 slots/port. X-port direct receiver access (DRA) without coupler option. 50 MHz to 9 GHz. X is available as even number from 2-port (Option 302) to 12-port (Option 312) . 1 slot/port. Option...
Open the catalog to page 11All KEYSIGHT TECHNOLOGIES catalogs and technical brochures
-
Network Visibility Products
24 Pages
-
RF Products
20 Pages
-
Basic Instruments
34 Pages
-
InfiniiVision 2000 X-Series
31 Pages
-
Signal Analyzers X-Series
21 Pages
-
KeysightCare
8 Pages
-
FieldFox and Nemo Handy
4 Pages
-
Impedance and Network Analysis
42 Pages
-
E4990A Impedance Analyzer
12 Pages
-
Keysight N6780 Series
10 Pages
-
E5071C ENA Network Analyzers
18 Pages
-
Keysight Process Analysis
7 Pages
-
BenchVue Software
2 Pages
-
Keysight Process Analysis
7 Pages
-
PXI RF Switch Modules
2 Pages
-
I/O Hardware
18 Pages
-
Digital Multimeters
28 Pages
-
Data Acquisition - DAQ
32 Pages
-
PCIe Digitizers
8 Pages
-
2015 Optical Component Test
40 Pages
-
Power Products Catalog
215 Pages
-
N9000A CXA Signal Analyzer
2 Pages
-
Agilent 89600 VSA Software
8 Pages
-
X-Series
23 Pages
-
CXA X-Series
8 Pages
-
SOLUTION BROCHURE
6 Pages
-
Waveguide Power Sensors
2 Pages
-
Power Meters and Power Sensors
34 Pages
-
E7515A UXM Wireless Test Set
2 Pages
-
E5063A Network Analyzer
8 Pages
-
N9320B RF Spectrum Analyzer
12 Pages
-
E5052B Signal Source Analyzer
21 Pages
-
N9038A MXE EMI Receiver
22 Pages
-
RDX Test Solutions for DigRF
17 Pages
-
M9252A DigRF Host Adapter
2 Pages
-
M9502A and M9505A
12 Pages
-
Oscilloscopes
16 Pages
-
Agilent Power Products
31 Pages
-
LIGHTWAVE CATALOG VOLUME I 2013
40 Pages
-
U4301A PCIe Analyzer
7 Pages
-
N9030A PXA Signal Analyzer
32 Pages
Archived catalogs
-
Agilent Technologies - Catalog
40 Pages