Catalog excerpts

InfiniiVision 2000 X-Series Oscilloscopes
Open the catalog to page 1
Want to Touch Operation and Additional Analysis Capabilities to Discover and Solve your problem? See the InfiniiVision 3000G X-Series. • 8.5-inch capacitive touch display Zone touch trigger capability Standard segmented memory Fully upgradable 7 instrument in 1 • Protocol analysis including new CAN-FD and SENT bus support 20 MHz WaveGen with arbitrary waveform and modulation support Frequency Response Analyzer N7020A Power Rail Probe and N2820A High Sensitivity Current Probe support Standard time gated FFT feature Eight additional standard features including: o Waveform & measurement...
Open the catalog to page 3
Breakthrough Technology for Budget Conscious Customers Overview of the Keysight InfiniiVision X-Series oscilloscopes InfiniiVision 1000 X-Series Analog channels Bandwidth (upgradable) Digital channels External trigger can be used as a 3rd digital channel for 2 channel model Maximum sample rate Maximum memory depth Waveform update rate 8.5-inch capacitive touch display 12.1-inch capacitive touch display 12.1-inch, capacitive touch, gesture enabled display Zone touch trigger Voice Control WaveGen 20-MHz function/ arbitrary waveform generator Single-channel function only (standard on G models)...
Open the catalog to page 4
USB 2.0 signal quality test HDTV analysis Advanced waveform math Standard USB 2.0 (LAN/video option) (GPIB option) Standard USB2.0 (LAN/video option) (GPIB option) Standard USB2.0, LAN, video out (GPIB option) Standard USB2.0, LAN, video out (GPIB option) The digital channels and serial protocol analysis cannot be used simultaneously on 2000 X-Series. More Scope The InfiniiVision 2000 X-Series offers entry-level price points to fit your budget with superior performance and optional capabilities that are not available in any other oscilloscope in its class. This Keysight Technologies, Inc....
Open the catalog to page 5
See More of your Signal, More of the Time Largest display Engineering for the best signal visibility starts with the largest display. Our 8.5‑inch WVGA display offers 50% more viewing area with 3.5 times the resolution (WVGA 800 x 480 versus 7-inch WQVGA 480 x 234). Notice that the Keysight 2000 X-Series allows you to see more of your signals and captures the infrequent glitch that you are unable to see on other oscilloscopes in this class. Fastest update rate With Keysight-designed MegaZoom IV custom ASIC technology, the InfiniiVision 2000 X-Series family delivers up to 200,000 waveforms...
Open the catalog to page 6
How does Keysight do that? Keysight-designed MegaZoom IV custom ASIC technology combines the capabilities of an oscilloscope, logic analyzer, and WaveGen built-in function generator in a compact form factor at an affordable price. 4th generation MegaZoom technology enables the industry’s fastest waveform update rate with responsive deep memory acquisitions.
Open the catalog to page 7
Do More with The Power of 5 Instruments In 1 Best-in-class oscilloscope The InfiniiVision 2000 X-Series features Keysight’s patented MegaZoom IV smart memory technology that is always enabled and always responsive providing the industry’s fastest update rate at up to 200,000 waveforms per second, with no compromise if you turn on measurements or add digital channels. In addition, the 2000 XSeries offers 25 automated measurements such as voltage, time, and frequency as well as 18 waveform math functions including add, subtract, multiply, divide, and FFT. Industry’s first economy-class mixed...
Open the catalog to page 8
Keysight’s InfiniiVision Series oscilloscopes are the industry’s first scopes to use hardware-based serial protocol decoding. Other vendors’ oscilloscopes use software post-processing techniques that slow down both waveform and decode update rate. That’s especially true when using deep memory, which is often required to capture multiple packetized serial bus signals. Faster decoding with hardware-based technology enhances scope usability and, more importantly, the probability of capturing infrequent serial communication errors. After capturing a serial bus communication, you can easily...
Open the catalog to page 9
Segmented memory When capturing low-duty cycle pulses or data bursts, you can use segmented memory acquisition to optimize acquisition memory. Segmented memory acquisition lets you selectively capture and store important segments of signals without capturing unimportant signal idle/dead-time. Segmented memory acquisition is ideal for applications including packetized serial pulses, pulsed laser, radar bursts and highenergy physics experiments. Up to 250 segments can be captured on the 2000 X-Series models with a minimum re-arm time under 5 µs. 30-day trial license The 2000 X-Series comes...
Open the catalog to page 10
Other Productivity Tools Reference waveforms Store up to two waveforms in the scope’s non-volatile reference waveform memory locations. Compare these reference waveforms with live waveforms and perform post analysis and measurements of stored data. You can also store waveform data on a removable USB memory device that can be recalled back into one of the available two reference memories of the scope for full waveform measurement and analysis. Save and/or transfer waveforms as XY data pairs in a comma-separated values format (*.csv) for PC analysis. Save screen images to a PC for...
Open the catalog to page 11
Probe solutions Get the most out of your 2000 X-Series scope, by using the right probes and accessories for your application. Keysight offers a complete family of innovative probes and accessories for the InfiniiVision 2000 X-Series scopes. For the most up-to-date and complete information about Keysight’s probes and accessories, please visit our Web site at www.keysight.com/find/scope_probes. Autoscale Quickly display any active signals and automatically set the vertical, horizontal and trigger controls for optimal viewing with the press of the autoscale button. (This feature can be...
Open the catalog to page 12
Connectivity and LXI compatibility Built-in USB host (one front, one back) and USB device ports make PC connectivity easy. Operate the scope from your PC and save and recall stored waveforms as well as set-up files via LAN. An optional LAN/VGA module gives you network connectivity and complete LXI class C support as well as the ability to connect to an external monitor. An optional GPIB module is also available. Only one module may be used at a time. A node-locked license for the BV0004B BenchVue Oscilloscope Control and Automation software can be redeemed at no additional cost for each...
Open the catalog to page 13All KEYSIGHT TECHNOLOGIES catalogs and technical brochures
-
Network Visibility Products
24 Pages
-
RF Products
20 Pages
-
Basic Instruments
34 Pages
-
Signal Analyzers X-Series
21 Pages
-
KeysightCare
8 Pages
-
FieldFox and Nemo Handy
4 Pages
-
Impedance and Network Analysis
42 Pages
-
E4990A Impedance Analyzer
12 Pages
-
Keysight N6780 Series
10 Pages
-
E5071C ENA Network Analyzers
18 Pages
-
Keysight Process Analysis
7 Pages
-
BenchVue Software
2 Pages
-
Keysight Process Analysis
7 Pages
-
PXI RF Switch Modules
2 Pages
-
I/O Hardware
18 Pages
-
Digital Multimeters
28 Pages
-
Data Acquisition - DAQ
32 Pages
-
PCIe Digitizers
8 Pages
-
2015 Optical Component Test
40 Pages
-
Power Products Catalog
215 Pages
-
N9000A CXA Signal Analyzer
2 Pages
-
Agilent 89600 VSA Software
8 Pages
-
X-Series
23 Pages
-
CXA X-Series
8 Pages
-
SOLUTION BROCHURE
6 Pages
-
Waveguide Power Sensors
2 Pages
-
Power Meters and Power Sensors
34 Pages
-
E7515A UXM Wireless Test Set
2 Pages
-
E5063A Network Analyzer
8 Pages
-
N9320B RF Spectrum Analyzer
12 Pages
-
E5052B Signal Source Analyzer
21 Pages
-
N9038A MXE EMI Receiver
22 Pages
-
RDX Test Solutions for DigRF
17 Pages
-
M9252A DigRF Host Adapter
2 Pages
-
M9502A and M9505A
12 Pages
-
Oscilloscopes
16 Pages
-
Agilent Power Products
31 Pages
-
LIGHTWAVE CATALOG VOLUME I 2013
40 Pages
-
U4301A PCIe Analyzer
7 Pages
-
N9030A PXA Signal Analyzer
32 Pages
Archived catalogs
-
Agilent Technologies - Catalog
40 Pages