34972A LXI Data Acquisition / Data Logger Switch Unit
28Pages

{{requestButtons}}

Catalog excerpts

34972A LXI Data Acquisition / Data Logger Switch Unit - 1

Agilent 34970A Data Acquisition/ Switch Unit Family Product Overview 34970A 34972A Agilent performance at a fraction of the cost of other standalone data acquisition systems • 3-slot mainframe with built-in 6½ digit DMM and 8 optional switch and control plug-in modules • Measures and converts 11 different input signals: temperature with thermocouples, RTDs and thermistors; dc/ac volts; 2- and 4-wire resistance; frequency and period; dc/ac current • Gigabit LAN, USB, GPIB or RS-232 IO options for easy connectivity to your PC • Graphical Web interface for point and click monitor and control (34972A) • USB flash drive support to copy/log data in standalone applications (34972A) • Includes BenchLink Data Logger Software to configure and control tests, display results and collect data for further analysis

Open the catalog to page 1
34972A LXI Data Acquisition / Data Logger Switch Unit - 2

2 Table of Contents 3 Features 6 34970A/34972A Power and Flexibility 7 34970A/34972A for your data acquisition applications 10 Using the 34970A/34972A for ATE applications 11 ATE feature checklist 12 Using the 34970A/34972A for switching applications 13 Customize your 34970A/34972A with plug-in modules 13 Modules at a glance selection guide 14 Agilent quality 15 Spec interpretation guide 16 Accuracy specifications 18 System measurement rates 19 System specifications 19 Agilent BenchLink Data Logger Software 20 Modules specifications 21 Multiplexer selection guide (34901A, 34902A, and...

Open the catalog to page 2
34972A LXI Data Acquisition / Data Logger Switch Unit - 3

3 handle it. The internal autoranging DMM directly measures 11 different functions, eliminating the need for expensive external signal conditioning. And our unique design allows complete per channel configurability for maximum flexibility and quick, easy set up. It’s like having an independent, high-performance DMM behind each channel. Standard connectivity to the PC Whether you use GPIB, RS-232, LAN or USB interfaces, the 34970A/34972A family offers easy connection to the PC. The 34972A has built-in Gigabit LAN and USB 2.0 so you can connect to a modern PC without having to purchase any...

Open the catalog to page 3
34972A LXI Data Acquisition / Data Logger Switch Unit - 4

4 Easy to use graphical Web interface (34972A only) The built-in graphical Web interface provides easy access and control of the instrument using a Java-enabled Web browser such as Internet Explorer. Using this interface you can configure measurements, define and execute scan lists, or monitor measurement results from anywhere on the network. Simply enter the instrument host name or IP address into the browser URL and gain access to the instrument’s capabilities with simple point and click control right in your browser. • Specify per channel measurement configuration • Define and execute...

Open the catalog to page 4
34972A LXI Data Acquisition / Data Logger Switch Unit - 5

5 Unequaled ease of use From the simplified configuration to the graphical Web interface in the 34972A, we put in extra time and energy so you don’t have to. Simple things like on-module screwterminal connectors, built-in thermocouple reference junctions, well-organized user documentation full of examples and hints, and a standard Getting Started kit that will have you making measurements in just a few minutes all add up to increased productivity, whether you use the instrument every day or only now and then. Custom confi gurations that grow with you Three module slots and eight...

Open the catalog to page 5
34972A LXI Data Acquisition / Data Logger Switch Unit - 6

6 More power and fl exibility than you ever imagined you could afford Intuitive front panel with task-oriented, self-guiding menus 50 k readings of non-volatile memory holds data when power is removed HI/LO alarm limits on each input channel, plus 4 TTL alarm outputs Scaling function for converting raw inputs into user-defined units 6½ digit (22-bit) internal DMM measures 11 functions without external signal conditioning Battery-backed real-time clock for pacing scans and timestamping readings Monitor display mode lets you keep an eye on tests in progress • Offers up to 96 matrix...

Open the catalog to page 6
34972A LXI Data Acquisition / Data Logger Switch Unit - 7

7 The Agilent 34970A/34972A offers unequaled versatility for your data acquisition applications In the past, you had to make a choice. On the one hand, you could choose the simple operation and low cost of a data logger. On the other hand, you had the flexibility and higher performance of a modular data acquisition system. The Agilent 34970A/34972A Data Acquisition/Switch Unit gives you the best of both worlds: a simple user interface with low per-channel cost, modular flexibility, standard connectivity and impressive measurement performance. Whether you’re an R&D engineer working on...

Open the catalog to page 7
34972A LXI Data Acquisition / Data Logger Switch Unit - 8

8 An easy-to-use data logger for monitoring and characterization applications Data loggers are used to monitor multiple signals (temperature, voltage, etc.) over extended periods of time to identify irregularities. Example applications include environmental chamber monitoring, component inspection, benchtop testing, process troubleshooting, and temperature profiling. The Agilent 34970A/34972A is easy to use for a multitude of data logging and monitoring applications, either standalone or with a computer. Its flexible, modular design makes it scalable from 20 to 120 channels, and lets you...

Open the catalog to page 8
34972A LXI Data Acquisition / Data Logger Switch Unit - 9

9 And the 34970A/34972A measures and converts 11 different input signals: • temperature with thermocouples, RTDs, and thermistors • dc and ac volts • 2- and 4-wire resistance • frequency and period • dc and ac current What’s more, each channel is independently configurable. This means you can configure channel 1—for dcV, channel 2 for a K-type thermocouple, and channels 3 and 13 for a 4-wire RTD measurement—all on the same module, all in a single scan. For custom linear conversions, use the Mx+B scaling function on any channel. You can even display a custom 3-character engineering label...

Open the catalog to page 9
34972A LXI Data Acquisition / Data Logger Switch Unit - 10

10 A powerful, fl exible data acquisition system for automated test The 34970A/34972A gives you the resolution, accuracy, repeatability, and speed you’ve come to expect from an Agilent data acquisition system. It provides the measurement muscle you need, along with signal routing and control capability, in a flexible, modular format that can grow and change to match your varied applications. Powerful measurements The internal 6½ digit DMM brings the power and performance of a world-class stand-alone DMM to the 34970A/34972A, but at a fraction of the cost and in a fraction of the space. It’s...

Open the catalog to page 10