
Catalog excerpts

Agilent 16800 Series Portable Logic Analyzers Data Sheet Features and benefits • 250 ps resolution (4 GHz) timing zoom to find elusive timing problems quickly, without double probing • 15” display, with available touch screen, allows you to see more data and navigate quickly • View Scope—time-correlated measurements and displays of your logic analyzer and oscilloscope data let you effectively track down problems across the analog and digital portions of your design • Eight models with 34/68/102/136/204 channels, up to 32 M memory depth and models with a pattern generator provide the measurement flexibility for any budget • Application support for every aspect of today’s complex designs—FPGA dynamic probe, digital VSA (vector signal analysis) and broad processor and bus support Quickly debug, validate, and optimize your digital system—at a price that fits your budget.
Open the catalog to page 1
Selection Guide for 16800 Series Portable Logic Analyzers Models with a built-in pattern generator give you more measurement flexibility.
Open the catalog to page 3
Logic Analysis for Tracking Real-time System Operation Agilent 16800 Series portable logic analyzers offer the performance, applications, and usability your digital development team needs to quickly debug, validate, and optimize your digital system—at a price that fits your budget. The logic analyzer’s timing and state acquisition gives you the power to: • Accurately measure precise timing relationships using 4 GHz (250 ps) timing zoom with 64 K depth • Find anomalies separated in time with memory depths upgradeable to 32 M • Buy what you need today and upgrade in the future. 16800 Series...
Open the catalog to page 4
Logic Analysis for Tracking Real-time System Operation (continued) Automate measurement setup and quickly gain diagnostic 16800 Series logic analyzers make it quickly by automating your measure- ment setup process. In addition, the logic analyzer's setup/hold window (or sampling position) and threshold voltage settings are automatically determined so you can capture data on high-speed buses with the highest accuracy. Auto Threshold and Sample Position mode allow you to... • Obtain accurate and reliable mea- • Save time during measurement • Gain diagnostic clues and identity- problem signals...
Open the catalog to page 5
Agilent 16800 Series Logic Analyzer Specifications and Characteristics Channel count per measurement mode 16801A/16821A Conventional timing Transitional timing for sample rates < 500 MHz Transitional timing for 500 MHz sample rate 1. Unused clock channels can be used as data channels. Timing zoom (Simultaneous state and timing without double probing—All channels, all the time) Timing analysis sample rate Time interval accuracy Within a pod pair Between pod pairs Memory depth Trigger position Minimum data pulse width 4 GHz (250 ps) ± (1.0 ns + 0.01% of time interval reading) ± (1.75 ns...
Open the catalog to page 6
Agilent 16800 Series Logic Analyzer Specifications and Characteristics (continued) State (synchronous) analysis mode tWidth* 1 tSetup tHold tSample range 2 tSample adjustment resolution Maximum state data rate on each channel Memory depth 4 1.5 ns 0.5 tWidth 0.5 tWidth –3.2 ns to +3.2 ns 80 ps typical 250 Mb/s Option 001: 1 M samples Option 004: 4 M samples Option 016: 16 M samples Option 032: 32 M samples 2 (1 for 16801A or 16821A) 4 (2 for 16801A or 16821A) 4 (2 for 16801A or 16821A) 4.0 ns 1 ns 1 ns 4.0 ns 1.5 ns 0.5 tWidth 0.5 tWidth –3.2 ns to +3.2 ns 80 ps typical 500 Mb/s Option 001:...
Open the catalog to page 7
Agilent 16800 Series Logic Analyzer Specifications and Characteristics (continued) State (synchronous) analysis mode Clock qualifier setup time Clock qualifier hold time Time tag resolution Maximum time count between stored states Maximum trigger sequence speed Maximum trigger sequence levels Trigger sequence level branching Trigger position Trigger resources 250 MHz 16 Arbitrary 4-way if/then/else Start, center, end, or user-defined • 16 patterns evaluated as =, =/, >, ≥, <, ≤ • 14 double-bounded ranges evaluated as in range, not in range • 1 timer for every 34 channels • 2 global counters...
Open the catalog to page 8
Agilent 16800 Series Logic Analyzer Specifications and Characteristics (continued) Timing (asynchronous) analysis mode Conventional timing Sample rate on all channels Sample rate in half channel mode Number of independent analyzers 1 Sample period (half channel) Minimum sample period (full channel) Minimum data pulse width Time interval accuracy 500 MHz 1 GHz 2 (1 for 16801A or 16821A) 1.0 ns 2.0 ns 1 sample period + 1.0 ns ± (1 sample period + 1.25 ns + 0.01% of time interval reading) Option 001: 1 M samples Option 004: 4 M samples Option 016: 16 M samples Option 032: 32 M samples Option...
Open the catalog to page 9
Agilent 16800 Series Logic Analyzer Specifications and Characteristics (continued) Timing (asynchronous) analysis mode Conventional timing Transitional timing Trigger resources • 16 patterns evaluated as =, =/, >, ≥, <, ≤ • 14 double-bounded ranges evaluated as in range, not in range • 3 edge/glitch • 1 timer for every 34 channels (no timer for 16801A or 16821A) • 2 global counters • 1 occurrence counter per sequence level • 4 flags Arbitrary Boolean combinations • Go To • Trigger, send e-mail, and fill memory • Trigger and Go To • Turn on/off default storing • Timer start/stop/pause/resume...
Open the catalog to page 10
A Built-in Pattern Generator Gives You Digital Stimulus and Response in a Single Instrument Selected 16800 Series models (16821A, 16822A and 16823A) also include a 48-channel pattern generator to drive down risk early in product development. With a pattern generator you can: • Substitute for missing boards, integrated circuits (ICs) or buses instead of waiting for missing pieces • Write software to create infrequently encountered test conditions and verify that the code works – before complete hardware is available • Generate patterns necessary to put a circuit in a desired state, operate...
Open the catalog to page 11All KEYSIGHT TECHNOLOGIES catalogs and technical brochures
-
Network Visibility Products
24 Pages
-
RF Products
20 Pages
-
Basic Instruments
34 Pages
-
InfiniiVision 2000 X-Series
31 Pages
-
Signal Analyzers X-Series
21 Pages
-
KeysightCare
8 Pages
-
FieldFox and Nemo Handy
4 Pages
-
Impedance and Network Analysis
42 Pages
-
E4990A Impedance Analyzer
12 Pages
-
Keysight N6780 Series
10 Pages
-
E5071C ENA Network Analyzers
18 Pages
-
Keysight Process Analysis
7 Pages
-
BenchVue Software
2 Pages
-
Keysight Process Analysis
7 Pages
-
PXI RF Switch Modules
2 Pages
-
I/O Hardware
18 Pages
-
Digital Multimeters
28 Pages
-
Data Acquisition - DAQ
32 Pages
-
PCIe Digitizers
8 Pages
-
2015 Optical Component Test
40 Pages
-
Power Products Catalog
215 Pages
-
N9000A CXA Signal Analyzer
2 Pages
-
Agilent 89600 VSA Software
8 Pages
-
X-Series
23 Pages
-
CXA X-Series
8 Pages
-
SOLUTION BROCHURE
6 Pages
-
Waveguide Power Sensors
2 Pages
-
Power Meters and Power Sensors
34 Pages
-
E7515A UXM Wireless Test Set
2 Pages
-
E5063A Network Analyzer
8 Pages
-
N9320B RF Spectrum Analyzer
12 Pages
-
E5052B Signal Source Analyzer
21 Pages
-
N9038A MXE EMI Receiver
22 Pages
-
RDX Test Solutions for DigRF
17 Pages
-
M9252A DigRF Host Adapter
2 Pages
-
M9502A and M9505A
12 Pages
-
Oscilloscopes
16 Pages
-
Agilent Power Products
31 Pages
-
LIGHTWAVE CATALOG VOLUME I 2013
40 Pages
-
U4301A PCIe Analyzer
7 Pages
-
N9030A PXA Signal Analyzer
32 Pages
Archived catalogs
-
Agilent Technologies - Catalog
40 Pages