IEC60945 Certificate(1)
55Pages

{{requestButtons}}

Catalog excerpts

IEC60945 Certificate(1) - 1

Test Report Key Technology (China) Limited Floor 7, Building S8, Fenggang Tianan Cyber Park, No. 208 Fenggang Section, Dongshen Road, Fenggang Town, DongGuan City, Guang Dong Province, P.R. China.Zip Code: 523703 Sample Name: IEC60945 keyboard and mouse mouse Sample Model: Receive Sample Date: Test Date: Reference Document: IEC 60945:2002 § 9.2 Conducted emissions § 9.3 Radiated emissions from enclosure port § 10.9 Immunity to electrostatic discharge § 10.4 Immunity to radiated radiofrequencies § 10.5 Immunity to fast transients § 10.6 Immunity to surges § 10.3 Immunity to conducted radio frequency disturbance § 10.8 Power Supply Failure § 11.2 Compass safe distance Test Result: Refer to the following report GUANGZHOU GRG METROLOGY & TEST CO., LTD. Issued Date: GUANGZHOU GRG METROLOGY & TEST CO., LTD. Address: No.163, Pingyun Road, West of Huangpu Avenue, Guangzhou, Guangdong, China Tel:(+86)400-602-0999 FAX:(+86)020-38698685 Web

Open the catalog to page 1
IEC60945 Certificate(1) - 2

Statement 1. The report is invalid without "special seal for inspection and testing"; some copies are invalid; The report is invalid if it is altered or missing; The report is invalid without the signature of the person who prepared, reviewed and approved it. 2. The sample information is provided by the client and responsible for its authenticity; The content of the report is only valid for the samples sent this time. 3. When there are reports in both Chinese and English, the Chinese version will prevail when the language problems are inconsistent. 4. If there is any objection concerning...

Open the catalog to page 2
IEC60945 Certificate(1) - 5

1. TEST RESULT SUMMARY Test Item Test mode Test Requirement Test Method Conducted Emission Measurement Radiated Electromagnetic Disturbance Measurement Radiated Radio-Frequency Electromagnetic Field (RS) Electrical Fast Transient/Burst Immunity Test Surge Immunity Test Mode1 Power Supply Failure Mode1 Injected Currents Susceptibility Test Class / Severity Table 5 IACS UR E10 Rev.7: 0.15 MHz-0.3 MHz, QP: 80 - 52 dBµ V/m; 0.3 MHz-30 MHz, QP: 52 - 34 dBµ V/m; 30MHz-1000MHz, QP: 54 dBµ V/m; 156MHz-165MHz, QP: 24 dBµ V/m; 1000MHz-6000MHz, AVG: 54 dBµ V/m Contact:± 6kV Air:± 8kV Performance...

Open the catalog to page 5
IEC60945 Certificate(1) - 6

2. GENERAL DESCRIPTION OF TUT 2.1 APPLICANT Name: Key Technology (China) Limited Floor 7, Building S8, Fenggang Tianan Cyber Park, No. 208 Fenggang Section, Dongshen Road, Fenggang Town, DongGuan City, Guang Dong Province, P.R. China.Zip Code: 523703 Key Technology (China) Limited Floor 7, Building S8, Fenggang Tianan Cyber Park, No. 208 Fenggang Section, Dongshen Road, Fenggang Town, DongGuan City, Guang Dong Province, P.R. China.Zip Code: 523703 2.3 THE HEAD OFFICE OF THE APPLICANT Name: Key Technology (China) Limited B703, Building 1, Tianan Cyber Park, Huang Ge North Rd, Longcheng...

Open the catalog to page 6
IEC60945 Certificate(1) - 7

2.7 SAMPLE CONNECTION DIAGRAM 2.8 LIST OF AUXILIARY EQUIPMENT Name of Equipment Serial Number

Open the catalog to page 7
IEC60945 Certificate(1) - 8

3. LABORATORY The tests & measurements refer to this report were performed by GuangzhouEMC Laboratory of Guangzhou GRG Metrology & Test Co.,Ltd. : No.163,Pingyun Road,WestofHuangpu Avenue,Guangzhou,Guangdong, China.

Open the catalog to page 8
IEC60945 Certificate(1) - 9

4. MEASUREMENT UNCERTAINTY Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the EUT as specified in CISPR 16-4-2: Measurement Immunity to Electrostatic Discharge(ESD) Immunity to radiated radiofrequencies (RS) Immunity to fast transients (EFT) Immunity to surges Immunity to conducted radio frequency disturbance (CS) Power Supply Failure Compass safe distance Conducted Emission(CE) Radiated emissions from enclosure port(RE) / 1) This uncertainty represents an expanded uncertainty expressed at approximately the 95% . This uncertainty...

Open the catalog to page 9
IEC60945 Certificate(1) - 10

5. LIST OF USED TEST EQUIPMENT AT GRGT Name of Equipment Serial Number Conducted Emission Measurement Shielded room Radiated Electromagnetic Disturbance Measurement EMI Receiver Composite antenna Horn antenna Loop antenna Semi-anechoic chamber Electrostatic Discharge (ESD) ESD generator Radiated Radio-Frequency Electromagnetic Field (RS) Log-periodic antenna Signal generator Horn antenna Semi-anechoic chamber Power probe Power probe Signal generator Electrical Fast Transient/Burst Immunity Test (EFT) EFT Generator Surge Immunity Test Surge Generator Injected Currents Susceptibility Test...

Open the catalog to page 10
IEC60945 Certificate(1) - 11

Serial Number Power probe Signal generator California lnstruments Hand-held single component Magnetometer Shanghai Maritime University Tape measure Magnetic field generator Shanghai TinDun EMS testing software ROHDE&SCHWARZ Amplifier Power Supply Failure Programmable Power California lnstruments Supply Testing software Compass Safe Distance Programmable Power California lnstruments Supply

Open the catalog to page 11
IEC60945 Certificate(1) - 12

6. EMISSION TEST 6.1 CONDUCTED EMISSION MEASUREMENT 6.1.1 LIMITS Frequency range (MHz) 0.01~0.15 Limits (dBμV) Quasi-peak 96~50 NOTE: (1) The lower limit shall apply at the transition frequencies. (2) The limit decreases in line with the logarithm of the frequency in the range of 0.01MHz~0.15MHz and 0.15MHz~0.35MHz. 6.1.2 TEST PROCEDURES Set the bandwidth of receiver Frequency (MHz) Receiver Bandwidth(Hz) 6.1.3 EXPERIMENT PROCEDURE 1) The EUT should be placed on a non-metallic table top with a table height of 0.8m. 2) The EUT should be 0.4m from the vertical reference ground plane. 3) The...

Open the catalog to page 12
IEC60945 Certificate(1) - 13

6.1.5 PHOTOGRAPH OF THE TEST ARRANGEMENT Test setup

Open the catalog to page 13
IEC60945 Certificate(1) - 14

6.1.6 TEST RESULTS Test Result: Standard: Test item: Temp./Hum.(%RH): EUT: Model: Note: Pass IEC 60945:2002 Conducted Emission 25.9℃/48%RH IEC60945 keyboard and mouse K-TEK-M440-OTB-FN-BL-NV-EM C-DWP / Probe: Power Source: Date: Mode Test by

Open the catalog to page 14
IEC60945 Certificate(1) - 15

Report No.: E202201244425-2-G1 Test Result: Standard: Test item: Temp./Hum.(%RH): EUT: Model: Note: Pass IEC 60945:2002 Conducted Emission 25.9℃/48%RH IEC60945 keyboard and mouse K-TEK-M440-OTB-FN-BL-NV-EM C-DWP / Probe: Power Source: Date: Mode Test by

Open the catalog to page 15
IEC60945 Certificate(1) - 16

6.2 RADIATED ELECTROMAGNETIC DISTURBANCE MEASUREMENT 6.2.1 LIMITS 0.15MHz~1000MHz: FREQUENCY (MHz) (1) The lower limit shall apply at the transition frequencies. (2) The limit decreases in line with the logarithm of the frequency in the range of 150kHz to 0.3MHz and 0.3MHz to 30MHz. 6.2.2 TEST PROCEDURE Set the bandwidth of receiver Frequency(MHz) 6.2.3 EXPERIMENT PROCEDURE 1) The radiated disturbance test is carried out in a semi-anechoic chamber, and the distance between the EUT and the receiving antenna is 3 m. 2) The EUT should be placed on a non-metallic table top with a table height...

Open the catalog to page 16

All Key Technology (China) Limited catalogs and technical brochures