Product catalog summary
Introduction to Venturi Fume Hoods
Venturi fume hoods leverage the Venturi effect to enhance airflow, particularly in the lower corners of the hood opening, improving containment and efficiency in laboratory settings.
Types of Fume Hoods
Kewaunee offers various fume hoods, including constant volume, variable air volume, bench-mounted, and floor-mounted options, catering to different laboratory needs, including ADA accessibility and teaching hoods.
Key Features
Features include LED lighting, large viewing heights, energy efficiency, low maintenance sash systems, electromechanical sash stops, and GFCI protected receptacles.
Selection Guide
Selection should consider safety, efficiency, and cost-effectiveness. Low Exhaust Volume (LEV) hoods are noted for reduced exhaust requirements and innovative design features.
Face Velocity and Baffle Design
Recommended face velocities range from 60 to 120 FPM. Venturi hoods operate effectively at lower velocities due to their design, with optimized baffle design for various applications.
Configurations and Materials
Available in bench, floor-mounted, and distillation configurations, with ADA-compliant designs. Liner materials include Kemglass, Phenolic Resin, and Stainless Steel, offering different levels of chemical and heat resistance.
Conclusion
Venturi fume hoods provide safe, efficient, and cost-effective solutions for laboratory environments, suitable for a wide range of applications.
Solvent Cleanability
Phenolic Resin and Kemglass are rated as Excellent or Good, while Stainless Steel is rated as Excellent or Fair.
Hood Liner Characteristics
Materials are rated from Excellent to Poor for hood liners.
Work Tops
Epoxy Resin work tops offer excellent chemical resistance and good heat resistance. Stainless Steel work tops, Types 304L and 316L, are noted for cleanability and heat resistance.
Sash Arrangements
Includes vertical, auto-return vertical, horizontal, and combination vertical/horizontal sashes, each with specific benefits and limitations.
Special Purpose Fume Hoods
Isotope hoods for radioactive materials and Perchloric Acid hoods with water wash-down features are highlighted.
Technical Specifications
Detailed specifications for various fume hood models, including airflow requirements, dimensions, and necessary components for assembly.
Airflow Requirements
CFM requirements for different sash openings and face velocities, with static pressure data for exhaust fan selection.
ANSI Z9.5 Minimum Flow Rate
Specifies minimum flow rates for compliance with ANSI standards.
Overview of LX Bench Fume Hoods
Specifications for V26, V30, V36, and V40 series, including sash opening heights, liner types, and sash frames.
Electrical and Accessories
Includes GFCI-protected receptacles, LED light fixtures, and electromechanical sash stops.
Additional Parts Required
Components such as worktops, cupsinks, and service fittings are necessary for complete assembly.
Technical Information
Detailed dimensions for installation and integration into laboratory environments.
Floor-Mounted Fume Hoods Overview
Specifications for V65, V66, V67, and V90 models, including dimensions, airflow requirements, and accessories.
Recommendations
Proper exhaust fan selection based on total pressure drop calculations is necessary.
Specifications and Procedures
Details on cupsinks, vent cutouts, and material compatibility, with guidelines for ordering and installation.
Standards and Norms
Includes standards for vent locations and cutout options.
Recommendations
Material-specific recommendations for configurations.
Key Data from Tables and Diagrams
Includes tables of models and configurations, service fittings specifications, and critical information on cupsinks and vent cutouts.
Additional Features
Ceiling enclosures and finished backs for fume hoods, with distillation racks for TruView hoods.
Specifications for Base Cabinets
Details on base cabinets, solvent storage, acid storage, and vacuum pump storage cabinets, with specific dimensions and standards compliance.
Fume Hood Accessories
Includes canopy hoods, rear fillers, and kemstruts.
Recommended Fume Hood Work Practices
Emphasizes selecting the right fume hood for safety and outlines basic safety practices.
Specifications and Features
Kewaunee Supreme Air Venturi fume hoods include fixed baffle configurations, explosion-proof lights, and fire-suppression systems.
Recommended Work Practices
Maintain a protective air barrier, check performance regularly, and avoid using the hood for storage.
Safety Checklist
Ensure appropriate hood type, adequate airflow, and removal of unnecessary items.
Glossary of Terms
Defines technical terms such as air foil, baffle, and face velocity.
Testing Protocols and Standards
Adheres to ASHRAE 110 and ANSI/AIHA Z 9.5 standards for safe performance.
Contact Information
Contact details for Kewaunee Scientific Corporation's offices in Singapore, India, and the USA.
See more

Catalog excerpts

VENTURI - High Performance Fume Hoods-1

VENTURI High Performance Fume Hoods

 Open the catalog to page 1
VENTURI - High Performance Fume Hoods-2

VENTURI EFFECT "A short tube with tapering constriction in the middle that causes an increase in velocity of flow…or creating suction." Oxford Dictionary Giovanni Batista Venturi – (1746-1822) The Venturi Port accelerates the airflow in the lower corners of the hood opening. patent pendin

 Open the catalog to page 2
VENTURI - High Performance Fume Hoods-3

Kewaunee’s Venturi Fume Hood Offering • Constant Volume • Variable Air Volume • Bench Mounted Hoods - 24"- 30"- 36" interior depths - 48" and 60" interior heights - 28" and 35" sash heights • Floor Mounted Hoods - 24"- 30"- 36" -48" interior depths - 83" interior height - 74" viewing height • TruView - Teaching Hoods • Sash offerings Vertical Split Vertical Horizontal Combination Split Combination • Liner Options: - Kemglass – FRP - Stainless Steel - Phenolic Resin Supreme Air Venturi V05 Vertical Rising Sash Bench Hood

 Open the catalog to page 3
VENTURI - High Performance Fume Hoods-4

Venturi Fume Hood Features Belt Driven Sash & Pulley System • Low maintenance, dual shaft, belt and gear driven, sash system utilizing lineal bearings in the sash track for smooth operation Light & Sash Stop Controller General Features • LED interior lighting with 15 intensity and 3 color settings • Large viewing height • Unparalleled containment • Low Flow/High Performance • Energy Efficient • Venturi post design improves corner airflow • Electromechanical sash stop integrated into sash track (mechanical sash stop on floor mounted hoods) • Flush airfoil for easy user access • Easily removable,...

 Open the catalog to page 4
VENTURI - High Performance Fume Hoods-5

Venturi Fume Hood Selection Guide LX Series Split Sash Hoods (Extra Length & Extra Height) Perchloric Acid Distillation Fume Hoods General Purpose Floor Mounted Hoods Double Sided Double Sided TruView Teaching Hoods Specialty Hoods LX Series Fume Hoods (Extra Height) Split Sash Hoods (Extra Length)

 Open the catalog to page 5
VENTURI - High Performance Fume Hoods-6

Part Number Explanation Venturi Fume Hood Catalog Number Explanation Base Part Number Required Styles V05F282472GN-G1,F1,SK-A1,V... Fume Hood Type Bench Fume Hoods V05 = Vertical Sash V06 = Combination Sash V07 = Horizontal Sash V10 = Split Vertical Sash V11 = Split Combo Sash V15 = ADA Vertical Sash V16 = ADA Combo Sash V25 = LX Vertical Sash V26 = LX Combo Sash V30 = LX Split Vertical Sash V36 = LX Split Combo Sash V40 = Isotope - Vertical Sash V45 = Perchloric Acid - Vertical Sash Floor Mounted Fume Hoods V65 = Vertical Sash V66 = Combination Sash V67 = Horizontal Sash Distillation Fume Hoods...

 Open the catalog to page 6
VENTURI - High Performance Fume Hoods-7

Part Number Explanation TruView Teaching Hood Catalog Number Explanation Base Part Number Required Styles V50F48SBGN-G1,F4,SK,SA-A1,V... Fume Hood Type TruView Teaching Hoods V50 = Vertical Sash V51 = Combination Sash V52 = ADA Vertical Sash V53 = ADA Combination Sash V55 = Double-Sided Vertical Sash V56 = Double-Sided Combo Sash V57 = Double-Sided ADA Vertical Sash V58 = Double-Sided ADA Combo Sash Hood Configuration Stand Alone = SA Left End of Run = LE Right End of Run = RE Add-on (Middle of Run) = AD Electrical Fixtures See previous page Service Fitting Holes TruView WaterSaver = F4 TruView...

 Open the catalog to page 7
VENTURI - High Performance Fume Hoods-8

Guide to Fume Hood Selection Introduction Selection of the proper type of fume hood to use in a laboratory should be based upon two interrelated considerations: 1. The hood must allow the user to perform the work in a safe, efficient manner. 2. The need to reduce air conditioning cost. The hood must be large enough to accommodate the required apparatus within the prescribed safe work area of the hood (6" behind the plane of the sash and 2" in front of the back baffle). The configuration of the hood should be such that apparatus can be moved in and out of the hood easily. The sash opening of the...

 Open the catalog to page 8
VENTURI - High Performance Fume Hoods-9

Guide to Fume Hood Selection Configurations Bench hoods are set on a worksurface approximately 36" above the floor and provide a convenient work area for the standing position. Distillation hoods are used where taller accessibility. These hoods are also apparatus is required and convenient used when a sitting position is desired access to the floor of the hood is needed. for work at the hood. They provide the same size work area as the ADA fume hoods are designed in corresponding bench hoods. accordance with the guidelines for Floor mounted hoods are used where taller apparatus is required or...

 Open the catalog to page 9
VENTURI - High Performance Fume Hoods-10

V05 – General Purpose Bench Fume Hood with Vertical Rising Sash 120 VAC 20 amp GFCI* protected duplex receptacles * when wired to a single circuit, as standard with Option U LED light fixture with illumination and color controller Electromechanical sash stop with push button override Available Sizes: Sash Opening Height: 28 inches / 711mm Inside Depth: Sash Opening Height Available Liner Types: Type 316L Stainless Steel Type 304L Stainless Steel Phenolic Resin Available Sash Frames: Powder Coated Steel Type 304L Stainless Steel see page 76 see page 78 see page 79 see page 80 see page 87 Inside...

 Open the catalog to page 10
VENTURI - High Performance Fume Hoods-11

Technical Information Airflow (CFM) Requirements 28" High Sash Opening 5'-0" / 60" 6'-0" / 72" Face Velocity Static pressures shown are for the pressure drop through the hoods only. The total pressure drop through the hood and the duct system must be calculated to select the proper exhaust fan. ANSI Z9.5 Minimum Flow Rate 150 Air Changes/Hour Inside Depth 24" deep 30" deep 36" deep Pipe Space Below Work Top Plumbing Access (both sides) EQ Pipe Space Below Work Top Plumbing Access (both sides) Electrical Junction Box on top of hood D Electrical Junction Box on top of hood Elevation Dimensions...

 Open the catalog to page 11
VENTURI - High Performance Fume Hoods-12

V06 – General Purpose Bench Fume Hood with Combination Vertical Rising/Horizontal Sash 120 VAC 20 amp GFCI* protected duplex receptacles * when wired to a single circuit, as standard with Option U LED light fixture with illumination and color controller Electromechanical sash stop with push button override Available Sizes: Sash Opening Height: 28 inches / 711mm Inside Depth: Sash Opening Height Available Liner Types: Type 316L Stainless Steel Type 304L Stainless Steel Phenolic Resin Available Sash Frames: Powder Coated Steel Type 304L Stainless Steel see page 76 see page 78 see page 79 see page...

 Open the catalog to page 12

All Kewaunee Scientific Corporation catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.