KERN test service DAkkS calibration and verification service for balances, test weights, force measurement and more
24Pages

{{requestButtons}}

Catalog excerpts

KERN test service DAkkS calibration and verification service for balances, test weights, force measurement and more - 1

KERN test service DAkkS calibration and verification service for balances, test weights, force measurement and more DAkkS calibration in accordance with DIN EN ISO/IEC 17025:2005 for balances, weights, force, volumes of solid bodies, densities of solid bodies PROFESSIONAL MEASURING

Open the catalog to page 1
KERN test service DAkkS calibration and verification service for balances, test weights, force measurement and more - 2

Your contact person at the KERN DAkkS calibration laboratory Team leader testing service distribution DE (PC 0, 1, 2, 3, 4), AT, CH, Asia, Eastern Europe, CIS Waldemar Fleitling Tel. +49 [0] 7433 9933 - 163 Fax +49 [0] 7433 9933 - 29163 fleitling@kern-sohn.com Testing service distribution DE (PLZ 8, 9), FR, DK, BeNeLux, Africa, TR, GR, South and North America, Oceania Athina Ioakimidou Tel. +49 [0] 7433 9933 - 123 Fax +49 [0] 7433 9933 - 29123 athina.ioakimidou@kern-sohn.com QM certification and accreditation by KERN as a basis for the highest level of quality. · DIN EN ISO 9001 · DIN EN...

Open the catalog to page 2
KERN test service DAkkS calibration and verification service for balances, test weights, force measurement and more - 3

The heart of calibration and verification The principle When should you carry out DAkkS calibration? Every electronic measuring device will only give correct results if it is checked regularly, i.e. calibrated correctly and adjusted when required. An electronic balance, test weight or another measuring device is only a reliable measuring and checking tool if it is calibrated and this calibration is documented as part of a quality procedure. DAkkS calibration is always necessary, when checking equipment is to be used in a QM process (e.g. in accordance with ISO 9000ff, TS 16949, VDA, FDA,...

Open the catalog to page 3
KERN test service DAkkS calibration and verification service for balances, test weights, force measurement and more - 4

All you need to know about calibration KERN & Sohn GmbH Ziegelei 1 72336 Balingen-Frommern Deutschland EU-Konformitätserklärung | EU Declaration of Conformity | UE Déclaration de conformité D Wir erklären hiermit unter alleiniger Verantwortung, dass das Produkt, auf das sich diese Erklärung bezieht, mit den nachstehenden Richtlinien übereinstimmt. Das Produkt wurde unter Berücksichtigung untenstehender Normen gefertigt und entspricht den genannten Richtlinien. Die Produkte sind konform mit den Grundlegenden Anforderungen des Anhang I der EG Richtlinie 93/42/EWG und dürfen somit mit CE 0297...

Open the catalog to page 4
KERN test service DAkkS calibration and verification service for balances, test weights, force measurement and more - 5

KERN test services at a glance Calibration of balances inhouse (at KERN) DAkkS calibration certificates for force-measurement With the shortest calibration time in the KERN calibration laboratory of maximum 4 working days after receipt of order, this gives you almost uninterrupted use of your balances within your production process.s. Through the force-measurement accreditation from KERN (in Newtons), DAkkS calibration of your force-measuring devices means that we can meet the highest requirements. With test stands and measuring procedures designed for this purpose, our specialists can...

Open the catalog to page 5
KERN test service DAkkS calibration and verification service for balances, test weights, force measurement and more - 6

The balance Calibration of balances Any balance will only give correct results if it is checked regularly, i.e. calibrated correctly and adjusted when required. A balance is only a reliable measuring and checking tool if it is calibrated and this calibration is documented. The issued DAkkS calibration certificates are proof of the metrological traceability to national and international standards, as required by the DIN EN ISO 9000 and DIN EN ISO/IEC 17025 standards, amongst others. KERN recommends a recalibration period of one year. The standard does not give a defined recalibration period....

Open the catalog to page 6
KERN test service DAkkS calibration and verification service for balances, test weights, force measurement and more - 7

KERN Wien Bern Exact measurements on-site E.g.: Pallet scale set up with 2 x 500 kg b) KERN on-site calibration (we visit you) In Germany, KERN has a close-knit network of KERN DAkkS calibration laboratory employees, who can carry out on-site calibration of balances up to 50 tonnes. THE ADVANTAGES OF USING THE KERN ON-SITE CALIBRATION: + alibration on-site at your premises C in the field of use + No risk of damage during transportation This on-site testing service is metrologically recommended, as your balance is in its field of use and can be calibrated without any possible transportation...

Open the catalog to page 7
KERN test service DAkkS calibration and verification service for balances, test weights, force measurement and more - 8

Calibration service for balances (DAkkS calibration) DEUTSCHER KALIBRIERDIENST DEUTSCHER KALIBRIERDIENST DEUTSCHER KALIBRIERDIENST Kalibrierlaboratorium / Calibration laboratory DEUTSCHER KALIBRIERDIENST Kalibrierlaboratorium / Calibration laboratory DAkkS calibration certificate for balances Akkreditiert durch die / accredited by the Kalibrierlaboratorium / Calibration laboratory Akkreditierungsstelle des Deutschen Kalibrierdienstes Kalibrierlaboratorium / Calibration laboratory Akkreditiert durch die / accredited by the Akkreditiert durch die / accredited by the Akkreditierungsstelle des...

Open the catalog to page 8
KERN test service DAkkS calibration and verification service for balances, test weights, force measurement and more - 9

Minimum weight of sample (in use) What is the lightest item you can weigh on your balance, while still achieving accurate and reliable weighing results? What exactly is the limit? The KERN minimum sample weight protocol accounts for the established minimum sample weight of your balance and its location of installation and use with the relative ▸ measuring uncertainty. With various safety coefficients and required weighing accuracy (process accuracy), depending on standard or quality-related requirements on the balance being used. The higher the selected safety coefficient, the higher the...

Open the catalog to page 9
KERN test service DAkkS calibration and verification service for balances, test weights, force measurement and more - 10

Adjustment at the location of installation Pricing table for adjustment at the location of installation Adjustment at the location of installation is necessary, as the measuring results of balances depend on the local gravitational force (gravitational acceleration) and therefore depend on the location of use. KERN can carry this out just before shipping at the factor, individually to suit the location of installation. What are the advantages of carrying out adjustment at the location of installation? For adjustment to the location of installation you need the value for gravitational...

Open the catalog to page 10
KERN test service DAkkS calibration and verification service for balances, test weights, force measurement and more - 11

Calibration and verification prices for electronic balances DAkkS initial calibration and recalibration of balances at the KERN factory Checking equipment Weighing range Analytical balances [Max] ≤ 5 kg [Max] > 5 kg Precision balances/Industrial scales [Max] ≤ 5 kg [Max] > 5 kg – 50 kg [Max] > 50 kg – 350 kg [Max] > 350 kg – 1500 kg [Max] > 1500 kg – 2900 kg1) [Max] > 2900 kg – 6000 kg1) [Max] > 6000 kg – 12000 kg1) Hanging scales/Crane scales [Max] ≤ 5 kg [Max] > 5 kg – 50 kg [Max] > 50 kg – 350 kg [Max] > 350 kg – 1500 kg [Max] > 1500 kg – 2900 kg [Max] > 2900 kg – 6000 kg [Max] > 6000 kg...

Open the catalog to page 11

All KERN & SOHN catalogs and technical brochures

Archived catalogs

  1. MEDICAL SCALES

    58 Pages

  2. MEDICAL SCALES

    66 Pages

  3. HBA 100-0