Routing ControlLogix to ControlLogix via Ethernet, DH+, ControlNet and Ethernet
1Pages

{{requestButtons}}

Catalog excerpts

Routing ControlLogix to ControlLogix via Ethernet, DH+, ControlNet and Ethernet - 1

Routing ControlLogix to ControlLogix via Ethernet, DH+, ControlNet and Ethernet Description of KEPServerEX device ID 192.168.111.116,1,[1,2,8,1,2,2,15,1,3,2,192.192.140.110,1],0 OPC Client Application AB CLX CLX C 0 1 2 3 CLX D 0 1 2 3 B CLX A 0 1 2 3 ControlLogix (A) Slot 0 = Logix 5550 Slot 1 = 1756-DHRI0 Channel B = Node 11 Slot 2 = 1756-CNB Channel A = Node 4 Slot 3 = 1756-ENBT IP = 192.168.125.116 Logix 5550 to Logix 5550 via DH+, ControlNet and Ethernet ControlLogix (B) Slot 0 = Logix 5550 Slot 1 = 1756-DHRI0 Channel A = Node 8 Slot 2 = 1756-CNB Channel A = Node 13 Slot 3 = 1756-ENBT IP = 192.188.185.117 CLX B 0 1 2 3 ControlLogix (C) Slot 0 = Logix 5550 Slot 1 = 1756-DHRI0 Channel A = Node 7 Slot 2 = 1756-CNB Channel A = Node 15 Slot 3 = 1756-ENBT IP = 192.180.140.118 ControlLogix (D) Slot 0 = Logix 5550 Slot 1 = 1756-DHRI0 Slot 2 = 1756-CNB Slot 3 = 1756-ENBT IP = 192.192.140.110 Ethernet DH+ ControlNet Ethernet Ethernet DH+ ControlNet 192.168.111.116 = IP of 1756-ENBT module of Device A ,1 = Port # of the 1756-ENBT module where you gain access to the Back plane of the ControlLogix PLC (see port reference key) ,[1 = Onto Slot 1 of Device A (1756-DHRIO module) ,2 = Out of Port 2 of the 1756-DHRIO module in Device A where Channel A = Port 2 (see port reference key) ,8 = Into Node 8 of Device B ,1 = Port # of the 1756-DHRIO module where you gain access to the Back plane of the ControlLogix PLC (see port reference key) ,2 = Onto Slot 2 of Device B (1756-CNB module) ,2 = Out of Port 2 of the 1756-CNB module in Device B (see port reference key) ,15 = Into Node 15 of Device C ,1 = Port # of the 1756-CNB where you gain access to the Back plane of the ControlLogix PLC (see port reference key) ,3 = Onto Slot 3 of Device C (1756-ENBT module) ,2 = Out of Port 2 of the 1756-ENBT module in Device C (see port reference key) .192.192.140.110 = IP of 1756-ENBT module of Device D ,1] = Port # of the 1756-ENBT module where you gain access to the Back plane of the ControlLogix PLC (see port reference key) ,0 = Slot # of the Logix 5550 CPU on the Target Device (see Target Device description) INTERFACE MODULE PORT 1 PORT 2 PORT 3 1756-ENBT Back plane Ethernet Network N/A 1756-DHRIO Back plane DH+ Network on Channel A DH+ Network on Channel B 1756-CNB Back plane ControlNet Network N/A SoftLogix EtherNet/IP Messaging Virtual Back plane Ethernet Network N/A

Open the catalog to page 1

All Kepware catalogs and technical brochures

  1. Scheduler

    2 Pages

  2. IoT Gateway

    2 Pages

  3. EFM Exporter

    2 Pages

  4. ClientAce

    1 Pages

Archived catalogs