1. Catalogs
  2. KEM Küppers Elektromechanik GmbH
  3. TRICOR Coriolis Mass Flow Meters | CLASSIC Series

TRICOR Coriolis Mass Flow Meters | CLASSIC Series

TRICOR Coriolis Mass Flow Meters | CLASSIC Series
1 / 28 PagesView full catalog

TRICOR Coriolis Mass Flow Meters | CLASSIC Series

Product catalog summary
Overview: The TRICOR Coriolis Mass Flow Meters from the CLASSIC Series are engineered for general industrial applications, offering reliable performance with features like direct mass flow, density, and temperature measurement, along with calculated volumetric flow. These meters are mechanically balanced to resist external influences and require minimal maintenance due to the absence of moving parts.
Key Features:
  • Customizable all-in-one instrument with process parameters.
  • Easy installation without the need for straight pipe runs.
  • High accuracy and repeatability, with optional custom calibrations.
  • Certifications for hazardous areas, including ATEX, IECEx, and cCSAus.
  • Optional high-pressure designs and extended warranties available.
Technical Specifications:
  • Flow Rates: Range from 325 kg/h to 230,000 kg/h, with a basic accuracy of ±0.3% for mass flow and ±0.4% for volume flow.
  • Density Measurement: Up to 2,500 kg/m³ with an accuracy of ±5.0 kg/m³.
  • Temperature Range: Process temperatures from -40°C to +200°C, depending on the version.
  • Pressure: Standard maximum pressure of 200 bar, with options up to 345 bar.
Transmitter Specifications:
  • TCE 8000/8100: Features interfaces like RS485 and options for HART and Foundation Fieldbus, a back-lit LCD screen, and supports programming via a front keyboard or software.
  • Power Supply: 24 V DC or 100-240 V AC with a maximum power consumption of 11 W.
Installation and Maintenance: Designed for easy installation with multiple mounting options, these meters do not require recalibration and include integrated diagnostics for performance verification.
Applications: Suitable for various industrial processes, including those requiring high-pressure and hazardous area certifications.
Additional Specifications: The document details ANSI and EN flange classes, installation lengths, and process connection codes. It lists ANSI flange classes (300, 600, 900) and EN flange classes (PN 40, PN 63, PN 100, etc.) with corresponding installation lengths. Material and face type for certain connections, such as 1.4404 [AISI 316L] Type C and E Faces, are specified.
Installation Lengths: Provided for different flange sizes and types, including slip-on and weld neck connections. Manufacturer approval is required for connections without specified installation lengths.
Process Connections: Various process connection codes are listed, such as TCM 0325, TCM 0650, with corresponding installation lengths. Details for Triclamp and NPT/G female thread connections are included.
Contact Information: Contact details are provided for different regions, including North & South America, China, the rest of the world, and Asia/Pacific, Middle East, with addresses and phone numbers for each location.
Notes: Specifications are subject to change without notice, and it is advised to contact the manufacturer for connections without specified installation lengths.
See more

Catalog excerpts

TRICOR Coriolis Mass Flow Meters | CLASSIC Series-1

CLASSIC Series | TRICOR Coriolis Mass Flow Meters TECHNICAL DATASHEET The TCM CLASSIC product line meets general industrial requirements out of the box. • TCE 8000 transmitters with an easy-to-use interface • Economically-priced, non-calibrated but with excellent repeatability • Optional custom-calibrated meters with high performance specifications

 Open the catalog to page 1
TRICOR Coriolis Mass Flow Meters | CLASSIC Series-2

CLASSIC Series | TRICOR Coriolis Mass Flow Meters 2 Original KEM/AWL document:TCM_E68_CLASSIC_D_EN_180729_E010 I Copyright KEM/AWL, Subject to change without notic

 Open the catalog to page 2
TRICOR Coriolis Mass Flow Meters | CLASSIC Series-3

TRICOR Coriolis Mass Flow Meters | CLASSIC Series 3 Original KEM/AWL document:TCM_E68_CLASSIC_D_EN_180729_E010 I Copyright KEM/AWL, Subject to change witho

 Open the catalog to page 3
TRICOR Coriolis Mass Flow Meters | CLASSIC Series-4

CLASSIC Series | TRICOR Coriolis Mass Flow Meters DESCRIPTION The TRICOR Coriolis Mass Flow Meters from TASI Flow are absolutely reliable and robust sensors in a variety of processes, performing multiple measurements simultaneously with customizable process parameters and multiple communication languages. The TRICOR production team mechanically balances every meter, assuring the dual tubes are dynamically aligned and in perfect balance before flow begins. The unique design and cutting edge manufacturing procedures ensure a meter with the highest resistance to external influences. FEATURES • All-in-one...

 Open the catalog to page 4
TRICOR Coriolis Mass Flow Meters | CLASSIC Series-5

TRICOR Coriolis Mass Flow Meters | CLASSIC Series PRODUCT OVERVIEW Compact version Exd housing: Wall mounted (remote version) Version with TCE 6000 (including options) Housing: Panel mounted (remote version) 5 Original KEM/AWL document:TCM_E68_CLASSIC_D_EN_180729_E010 I Copyright KEM/AWL, Subject to change without notic

 Open the catalog to page 5
TRICOR Coriolis Mass Flow Meters | CLASSIC Series-6

CLASSIC Series | TRICOR Coriolis Mass Flow Meters TCM SENSOR – TECHNICAL DATA FOR LIQUIDS TCM 0325 Max. Flow Rate (lb/min) Basic Accuracy (Mass Flow) ±0.3 % of flow rate (option: up to 0.1 % of flow rate) ±0.4 % of flow rate (option: up to 0.15 % of flow rate) Basic Accuracy (Volume Flow) Zero Stability up to 2,500 kg/m³ [2.5 g/cm3] (higher ranges on request) Density Range Density Accuracy Density Repeatability Process Temperature Range Temperature Repeatability Process and Ambient Process Connections female thread 1/2“ adaptors for flanges, dairy and tri-clamp flanges EN1092, ANSI B16.5, DIN2512,...

 Open the catalog to page 6
TRICOR Coriolis Mass Flow Meters | CLASSIC Series-7

ACCURACY FOR LIQUIDS (TCM 230K) Flow Rate of Full Scale Original KEM/AWL document:TCM_E68_CLASSIC_D_EN_180729_E010 I Copyright KEM/AWL, Subject to change without notice

 Open the catalog to page 7
TRICOR Coriolis Mass Flow Meters | CLASSIC Series-8

Max. allowed flow velocity (Ma 0.5). For gas applications, flow rate and pressure drop for individual sensor sizes are dependent on operating temperature, pressure and fluid composition. Therefore, when selecting a sensor for any particular gas application, please use the the TSP (TRICOR Sizing Program) or contact us. 11 Nominal flow rates that produce approximately 3 bar [43 psi] pressure drop for natural gas at 50 bar [725 psi] operational pressure. 2) Normal reference conditions (Nm3/h) are 1,013 bar und 0 0C. Standard (SCFM) reference conditions are 14.7 psi und 60 0F. 3) Flow rate and density...

 Open the catalog to page 8
TRICOR Coriolis Mass Flow Meters | CLASSIC Series-9

ACCURACY FOR GASES Flow Rate of Full Scale 4 For Ex1, Ex3, EAC (TR-CU) the electronic is only available in aluminum housing. 5) Only with remote electronics. Original KEM/AWL document:TCM_E68_CLASSIC_D_EN_180729_E010 I Copyright KEM/AWL, Subject to change without notice

 Open the catalog to page 9
TRICOR Coriolis Mass Flow Meters | CLASSIC Series-10

Original KEM/AWL document:TCM_E68_CLASSIC_D_EN_180729_E010 I Copyright KEM/AWL, Subject to change without notice

 Open the catalog to page 10
TRICOR Coriolis Mass Flow Meters | CLASSIC Series-11

Original KEM/AWL document:TCM_E68_CLASSIC_D_EN_180729_E010 I Copyright KEM/AWL, Subject to change without notice

 Open the catalog to page 11
TRICOR Coriolis Mass Flow Meters | CLASSIC Series-12

Sensor Type 6) Other connections on request. 7) Further lengths on request. Original KEM/AWL document:TCM_E68_CLASSIC_D_EN_180729_E010 I Copyright KEM/AWL, Subject to change without notice

 Open the catalog to page 12
TRICOR Coriolis Mass Flow Meters | CLASSIC Series-13

Sensor Type 8) Further lengths on request. Original KEM/AWL document:TCM_E68_CLASSIC_D_EN_180729_E010 I Copyright KEM/AWL, Subject to change without notice

 Open the catalog to page 13
TRICOR Coriolis Mass Flow Meters | CLASSIC Series-14

CLASSIC Series | TRICOR Coriolis Mass Flow Meters METER-MOUNT TRANSMITTER TCE 8000/8100 203mm 7.99in e Original KEM/AWL document:TCM_E68_CLASSIC_D_EN_180729_E010 I Copyright KEM/AWL, Subject to change without notice rogr R01 In P29.03.2018 M

 Open the catalog to page 14
TRICOR Coriolis Mass Flow Meters | CLASSIC Series-15

TRICOR Coriolis Mass Flow Meters | CLASSIC Series METER-MOUNT TRANSMITTER TCE 8000/8100 WITH BLIND COVER 147mm 5.79in Datum Donnerstag, 6. Oktober 2016 13:44:49 Name griebel METER-MOUNT TRANSMITTER TCE 8000/8100 HIGH TEMPERATURE 147mm 5.80in Datum Donnerstag, 29. September 2016 14:50:08 Name griebel 15 Original KEM/AWL document:TCM_E68_CLASSIC_D_EN_180729_E010 I Copyright KEM/AWL, Subject to change without notic

 Open the catalog to page 15
TRICOR Coriolis Mass Flow Meters | CLASSIC Series-16

CLASSIC Series | TRICOR Coriolis Mass Flow Meters STANDARD CONNECTION HEAD (A) 68mm 2.68in Datum Mittwoch, 30. März 2016 09:25:15 Name griebel HIGH TEMPERATURE CONNECTION HEAD (H) 85mm 3.33in 16 Original KEM/AWL document:TCM_E68_CLASSIC_D_EN_180729_E010 I Copyright KEM/AWL, Subject to change without noti

 Open the catalog to page 16
TRICOR Coriolis Mass Flow Meters | CLASSIC Series-17

TRICOR Coriolis Mass Flow Meters | CLASSIC Series PANEL-MOUNTED HOUSING 143mm 5.64in 96mm 3.78in Name griebel 17 Original KEM/AWL document:TCM_E68_CLASSIC_D_EN_180729_E010 I Copyright KEM/AWL, Subject to change without notic

 Open the catalog to page 17
TRICOR Coriolis Mass Flow Meters | CLASSIC Series-18

CLASSIC Series | TRICOR Coriolis Mass Flow Meters REMOTE DISPLAY TRD 8001 * Moun�ng holes 18 Original KEM/AWL document:TCM_E68_CLASSIC_D_EN_180729_E010 I Copyright KEM/AWL, Subject to change without not

 Open the catalog to page 18
TRICOR Coriolis Mass Flow Meters | CLASSIC Series-19

ORDERING CODE TCM SENSOR (TRICOR CLASSIC SERIES) TCM XXXX - XX - X X X X Mechanical Options Medium Temperature Range -40 °C ... +100 °C [-40 °F ... +212 °F] S Pressure Range With rupture disc max. 4 bar [58 psi] G Mechanical Design Standard S Face to Face Length Standard (other length on request) S Electronics Options Electronics Type Junction box, 1.4404 [316L] Meter mount, die cast aluminum housing for 14" NPT cable glands10) Meter mount, die cast aluminum housing for M20x1.5 cable glands10) Meter mount, stainless steel housing for 14" NPT cable glands10) Meter mount, stainless steel housing...

 Open the catalog to page 19
TRICOR Coriolis Mass Flow Meters | CLASSIC Series-20

Housing Wall mount (housing for A" NPT cable glands) Wall mount (housing for M20x1.5 cable glands) Panel mount71 Supply Voltage 24 V DC + 90 ... 264 V AC (only housing S) B Electronic Options Standard S Pressure compensation, 4 ... 20 mA input A Cable Length 3 Meters [= 10 ft.], Standard (high temperature) S (H) 6 Meters [= 20 ft.] (high temperature) B (I) 10 Meters [= 33 ft.] (high temperature) C (J) 15 Meters [= 49 ft.] (high temperature) D (O) 20 Meters [= 65 ft.] (high temperature) E (P) 3 Meters [= 10 ft.], offshore cable F D-SUB Connector (hous ing S), seperate cable required N Ex-Protection...

 Open the catalog to page 20
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.