Piezoresistive Pressure Transmitters Series 21 Y - 2 Pages

Add to MyDirectIndustry favorites
Piezoresistive Pressure Transmitters Series 21 Y

Catalog excerpts

Piezoresistive Pressure Transmitters for industrial applications Technology: The Y-line transmitters have an extremely small temperature error. This is achieved using an additional circuit containing a temperature sensor that subdivides the temperature range into fields that are 1,5 Kelvin (K) wide. The TK zero and TK compensation values are calculated for each field and programmed into the additional circuit. During operation, these values are fed into the analogue signal path depending on the temperature. Each temperature is the „calibration temperature” for this transmitter. The accuracy thereof is mainly determined by linearity. 120 fields are available, representing a possible temperature range of 180 K. The wider the temperature range, the greater the amount of testing that is needed to minimise the inaccuracy of the mathematical model. Flexibility: The extent of the vertical range of manufacture, the modular design and the programmable electronics make it possible to manufacture large, customer-specific batches. The pressure sensors (insulated measuring cells) are manufactured in large quantities and kept in stock. These are then welded into the required transmitter head, equipped with electronics and calibrated over the entire temperature and pressure range in systems with up to 1000 measuring stations. mPm connectors, M12 connectors, Packard connectors and cable connections are used as standard for the electrical connection. In the relative pressure version, the ambient pressure is led into the interior via cable or connector. Outputs: A 2-wire (4…20 mA) or 3-wire version with voltage output is available as an output signal. For a ratiometric 0,5 to 4,5 V version, we refer to the KELLER Series 21 C product range. EMC: The 21 Y product line is outstanding due to its extreme ruggedness towards electromagnetic fields. The limits of the CE standard are undercut by a factor of up to 10 with conducted and radiated fields. These transmitters are also extremely immune to external voltages between the housing and the electrical connection, which is particularly important when frequency converters are being used. The high insulation voltage of 300 V make this product ideal for use in the harshest of environments. Pressure Connections Packard Plug Electrical Connections KELLER AG für Druckmesstechnik CH-8404 Winterthur +41 52 235 25 25 info@keller-druck.com KELLER Ges. für Druckmesstechnik mbH DE-79798 Jestetten +49 7745 9214 0 eurocenter@keller-druck.com KELLER America Newport News, Virginia 1 877 253 5537 sales@kelleramerica.com Edition 02/2018 Subject to alterations Companies approved to ISO 9001 www.kel

 Open the catalog to page 1

□ KELLER Specifications Pressure Ranges (all intermediate ranges possible) PR-21 Y    2...30 bar FS Overpressure    2 x pressure range, max. 1100 bar PAA: Absolute. Zero at vacuum PA: Sealed Gauge. Zero at 1000 mbar abs. PR: Vented Gauge. Zero at atmospheric pressure * Measuring range > 600 bar only suited for static applications Accuracy 1)    typ. ±0,25 %FS    max. ±0,5 %FS Total Error Band 2)    0...50 °C    max. ±1,0 %FS Type Signal Output Limitation Signal Output Supply Load Resistance Limiting Frequency Power Consumption Electrical Connection - Plug: M12 (4-pole), Packard, mPm - Cable...

 Open the catalog to page 2

All KELLER catalogs and technical brochures

  1. KELLER

    36 Pages

  2. Series 26 Y

    2 Pages

  3. Series 26 W

    1 Pages

  4. Handpump K/P

    1 Pages

  5. K-114 BT

    3 Pages

  6. K-114

    3 Pages

  7. 21 ge

    1 Pages

  8. LEO 3

    1 Pages

  9. FA-23

    1 Pages

  10. Series 8

    2 Pages